Description of Sensor Parameters
2
0
1
7
-0
6
55
8.4.4
Averages & Skip Count
You can use this parameter to control the depths of the average determination. M defines the
total number of measurements which are used to generate average determination. N defines
the number of measurements from the number of M which are not taken into account for
average determination. These are the value/values with the greatest deviation from the
measurement result most recently determined. The current measurement result is calculated
arithmetically from the remaining data.
8.4.5
Weighting of Former Measurement
Note!
This parameter is only relevant and visible in the DTM if the "Evaluation method" is set to
"Average value."
Parameter name
Access
Value range
Averages & skip count
Read/write
■
M=2, N=0
■
M=3, N=0
■
M=3, N=1
■
M=4, N=0
■
M=4, N=1
■
M=5, N=0
■
M=5, N=1
■
M=5, N=2
■
M=6, N=0
■
M=6, N=1
■
M=6, N=2
■
M=7, N=0
■
M=7, N=1
■
M=7, N=2
■
M=7, N=3
■
M=8, N=0
■
M=8, N=1
■
M=8, N=2
■
M=8, N=3
Table 8.23
Note!
This parameter is only relevant and visible in the DTM if the "Evaluation method" parameter is
set to "Low pass."
Parameter name
Access
Value range
Weighting of former
measurement
Read/write
1 ... 99 [%]
Table 8.24