USB Intrinsic Safety 

Barrier

SK-PC-D2-UU1-10-HS

PROCESS AUTOMATION

MANUAL

Содержание SK-PC-D2-UU1-10-HS

Страница 1: ...USB Intrinsic Safety Barrier SK PC D2 UU1 10 HS PROCESS AUTOMATION MANUAL...

Страница 2: ...Delivery for Products and Services of the Electrical Indus try published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its most r...

Страница 3: ...Technical Data 7 2 3 Dimensions 9 2 4 Transport Storage and Maintenance 9 2 5 Disposal 9 3 Installation and Commissioning 10 3 1 General Installation Requirements 10 3 2 Intrinsically Safe Wiring and...

Страница 4: ...examination certificate EU declaration of conformity Attestation of conformity Certificates Control drawings Additional documents 1 2 Target Group Personnel Responsibility for planning assembly commi...

Страница 5: ...displayed in descending order as follows Informative Symbols Action This symbol indicates a paragraph with instructions You are prompted to perform an action or a sequence of actions Danger This symbo...

Страница 6: ...The barrier provides protected USB 1 1 or PS2 power and data signals to an Ex rated mouse keyboard in the field The barrier shall be installed according to all applicable standards and regulations fo...

Страница 7: ...against electrical shock IEC 61140 Ambient conditions Ambient temperature 40 60 C 40 140 F Relative humidity 0 95 noncondensing Vibration resistance 5 G 58 150 Hz Impact resistance 15 g 11 ms Mechanic...

Страница 8: ...g at field terminals for Class I Zone 2 Group IIC and Group IIIB hazardous locations USL Class I Zone 2 AEx nA ic IIC T6 Gc Class I Zone 2 AEx nA ic IIIB IIC T6 Gc CNL Class I Zone 2 Ex nA ic IIC T6 G...

Страница 9: ...one Store all devices in a clean and dry environment 2 5 Disposal Disposal of devices and their packaging material must be performed in compliance with the applicable laws and guidelines of the corre...

Страница 10: ...ble Parameters Only use cables that meet the requirements of IEC EN 60079 14 to connect to the terminals on the barrier The cable length from the barrier to the keyboard mouse and from the barrier to...

Страница 11: ...2 UU1 10 HS barrier to the host PC as follows Grounding is executed via the host PC The precondition for this is that the GND line of the PC USB connection is internally connected to ground This must...

Страница 12: ...16 Grounding is executed via terminal 16 In common application scenarios pins number 4 minus wires of the host USB connectors are connected within the host If not connect pins 4 together to terminal...

Страница 13: ...ite Input 2 Host 11 D I O Green 12 D I O White Supply 13 PWR Supply 14 PWR Supply Input 1 host 15 GND Supply Black ground from host Input 2 host 16 GND Supply Black ground from host Connector Terminal...

Страница 14: ...Intrinsic Safety Barrier Appendix 4 Appendix 4 1 Accessories Item Number Name Description Contact sales for individual configuration EXTA 3 product family Keyboard and mouse system stand alone option...

Страница 15: ...rl fuchs com Worldwide Headquarters Pepperl Fuchs GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com For the Pepperl Fuchs representative closest to you check www pepperl fu...