201
5-0
3
32
Pulscon LTC57 PROFIBUS PA
Mounting
Installation from the side
Figure 6.13
• If installation from above is not possible, the device can also be mounted from the side.
• In this case, always fix the rope probe.
• Support rod probe if the lateral load bearing capacity is exceeded. Only fix rod probes at
the probe end.
Non-metallic vessels
Figure 6.14
To measure, device with a rod probe needs a metallic surface at the process connection.
Therefore:
• Select an instrument version with metal flange (minimum size DN50/2 in).
• Or: mount a metal sheet with a diameter of at least 200 mm (8 in) to the probe at the
process connection. Its orientation must be perpendicular to the probe.
1
Non-metallic vessel
2
Metal sheet or metal flange
Ø
16
(Ø
0.63)
Ø
16.5
(0.65)
Ø
<26
(Ø
<1.02)
mm (in)
1
2