Output function in normal operation
201
5-0
6
17
7
Output function in normal operation
Example
Figure 7.1
Output function depends on the position of the actuator and the method used to
program the outputs.
1. Marking for angle position 0
°
(default setting is analog output I/U)
2. Position of the second switching point of switching output S1 (example 40
°
)
3. Position of the first switching point of switching output S1 (example 60
°
)
4. Position of the first switching point of switching output S2 (example 250
°
)
5. Position of the second switching point of switching output S2 (example 310
°
)
6. Start position of analog output S3 (example 20
°
)
7. End position of analog output S3 (example 110
°
)
8. Angular range outside of analog measurement range. The function of the analog output
depends on whether the output assumes the function of a voltage or a current output (de-
pending on the load). See chapter 4.1
Current output:
If the measurement range is exceeded, the analog output value adopts the error signal 3.6
mA. The current output issues this fault current until the position of the actuator falls within
the programmed analog measurement range again.