PMI360DV-F130-IU2E0-V15
Inductive Angle Positioning System
FACTORY AUTOMATION
MANUAL
Страница 1: ...PMI360DV F130 IU2E0 V15 Inductive Angle Positioning System FACTORY AUTOMATION MANUAL...
Страница 2: ...of Delivery for Products and Services of the Electrical Indus try published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its mos...
Страница 3: ...Connection Cables 9 4 3 2 Actuator 10 5 Installation 11 5 1 Note on Safety 11 5 2 Mounting 11 5 3 Electrical Connection 12 6 Commissioning 14 6 1 Programming the Switching Outputs 14 6 2 Programming...
Страница 4: ...4 PMI360DV F130 IU2E0 V15 9 Troubleshooting 22 9 1 Faults when Programming the Outputs 22 9 2 Faults During Operation 22 10 Disposal 24...
Страница 5: ...worldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about the dev...
Страница 6: ...developed and manufactured under observance of the applicable European standards and guidelines The product manufacturer Pepperl Fuchs GmbH D 68307 Mannheim has a certified quality assurance system t...
Страница 7: ...ioning of all devices may only be performed by trained and qualified personnel User modification and or repair are dangerous and will void the warranty and exclude the manufacturer from any liability...
Страница 8: ...log output for the analog indication of angular positions For high resistance loads 3 3 k the angular position is output as a voltage value 0 10 VDC and for low resistance loads 400 as a current value...
Страница 9: ...utput and the outer S1 and S2 buttons are used to configure the start and end of the detection zone of the two switching outputs on the sensor The S1 S2 and I U LEDs correspond to the S1 S2 and I U pr...
Страница 10: ...ordsets from our extensive range of accessories 4 3 2 Actuator The BT F130 A actuator is designed for mounting directly on the drive shaft or a servodrive Illustration Material Length Model number M12...
Страница 11: ...r must not make physical contact or scratch the sensors surface when moving Using a different actuating element You may use a different actuator instead of the BT F130 A actuator provided When using a...
Страница 12: ...inner surface E Sensor F Insert the shaft until actuator C and the sensitive surface on sensor D overlap as far as possible Dimension Value t 2 mm w 7 5 mm d1 Depends on the drive shaft material S235...
Страница 13: ...Check that the wires are connected correctly before connecting the cordset to the sensor On Pepperl Fuchs cordsets the wire colors are assigned to the connecting pins in the connector according to DI...
Страница 14: ...ed off which prevents the electrical output signal from wavering The switching hysteresis is located at the top or bottom end of the switching window depending on the direction of rotation of the actu...
Страница 15: ...Move the actuator to the position that you wish to define as the switching window end point The actuator s direction of rotation is decisive here At the end of programming the area covered by the act...
Страница 16: ...rocess is terminated The sensor continues operating with unchanged values Note If any other button is actuated the programming process is terminated The sensor continues operating with unchanged value...
Страница 17: ...wise counterclockwise If the actuator rotates less than 30 the previously set direction of rotation is retained 6 Briefly press the I U button The setting is then stored in the non volatile memory of...
Страница 18: ...t and end point are parameterized a measurement range of 360 is programmed The measurement range start point is then located in the position defined in the first step The previous preset direction of...
Страница 19: ...Position of the second switching point of switching output S1 example 40 3 Position of the first switching point of switching output S1 example 60 4 Position of the first switching point of switching...
Страница 20: ...s of actuator an active switching output changes to an idle state up position and a switching output already in an idle state remains in this state The Power Error LED lights up red when the actuator...
Страница 21: ...when actuator is lost If the actuator leaves the sensing range of the angular positioning system e g actuator is removed the output logic depends on whether the analog output assumes the function of...
Страница 22: ...e associated yellow LED starts to flash slowly after 2 seconds 2 Continue to hold the sensor button The LED begins to flash more quickly after an additional 10 seconds 3 Then release the button within...
Страница 23: ...present or different actuator mounted too far away from the surface of the sensor Mount actuator according to specifications Power Error LED lights up red during programming Actuator lost during the p...
Страница 24: ...No actuator in the detection area of the sensor or unreliable detection of the actuator Check that the actuator used is mounted correctly or install an actuator with appropriate dimensions at the corr...
Страница 25: ...osal Electronic waste is hazardous waste When disposing of the equipment observe the current statutory requirements in the respective country of use as well as local regulations The device does not co...