Function of Switching Outputs S1, S2, and S3
8
Function of Switching Outputs S1, S2, and S3
The position of the actuator determined by the angular positioning system is based on half of
the actuator width (center of the actuator). The switch points are preset to the angle settings 0
°
(S3), 120
°
(S1), and 240
°
(S2) at the factory with a minimum window range of 5
°
. The switch-
on and switch-off points can be programmed at any desired position.
If the actuator falls in one of the programmed switching windows, the corresponding switching
output is activated. When a switching output is active, the corresponding yellow LED lights up.
If the actuator is positioned outside of a programmed switching window, the relevant switching
output changes to an idle state. When the actuator leaves the detection area of the angular
positioning system (loss of actuator), an active switching output changes to an idle state ("up"
position), and a switching output already in an idle state remains in this state. The "Power/Error"
LED lights up red when the actuator is lost.