background image

VisuNet FLX Panel

RM-320P-*
PC-320P-*
DM-320P-*

Manual

Содержание PM-KIT-3200-15-304-N0

Страница 1: ...VisuNet FLX Panel RM 320P PC 320P DM 320P Manual...

Страница 2: ...sion as well as the supplementary clause Expanded reservation of proprietorship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs c...

Страница 3: ...plates 19 4 Mechanical Installation 22 4 1 Unpacking 22 4 2 Panel Installation 23 4 3 General Installation Information 24 4 4 Mounting the Panel in the enclosure 25 5 Electrical Installation 31 5 1 Eq...

Страница 4: ...2021 04 4 VisuNet FLX Panel History of the Manual 1 History of the Manual The following editions of the manual have been released Version Comments 04 2021 First edition...

Страница 5: ...ion of conformity Certificates Control drawings Additional documents 2 2 Manufacturer 2 3 Target Group Personnel Responsibility for planning assembly commissioning operation maintenance and dismount i...

Страница 6: ...yed in descending order as fol lows Informative Symbols Action This symbol indicates a paragraph with instructions You are prompted to perform an action or a sequence of actions Danger This symbol ind...

Страница 7: ...sion standards are valid All dimensions are in mm Unless otherwise specified the following general tolerances are valid Nominal dimension ranges Nominal dimension range General tolerance according to...

Страница 8: ...ty Due to a fully modular design the new platform which is geared to the needs of the petro chemical and pharmaceutical indus tries the HMIs can be configured to fit exactly and enable simple and fast...

Страница 9: ...or non optical bonding 19 display touch screen hardened front glass with optical bonding 15 display touch screen hardened front glass with optical bonding 2 RAM Storage RAM available as 4 GB 8 GB ans...

Страница 10: ...PU Connecting the BPC3200 to the DPU3200 Panel dimensions Cut out dimensions VisuNet FLX System manual System installation mechanical electrical Power connection DC and AC Installing peripherals Maint...

Страница 11: ...Wide temperature grade temperature option B K 1x 4 GB DDR4 2133 Celeron L 1x 8 GB DDR4 2133 M 1x 16 GB DDR4 2133 Mass storage Storage interface 1x M 2 2242 2280 M Key PCIe SATA 3 1x M 2 2242 2280 M Ke...

Страница 12: ...dustrial temperature grade temperature class A K 1x 4 GB DDR4 2133 wide temperature grade Mass storage Storage interface 1x M 2 2242 2280 M Key PCIe SATA 3 Configurable storage options A 32 GB M 2 SAT...

Страница 13: ...Typically 22GT 1000 1 22FC 5000 1 19SC 1000 1 15FC 800 1 Brightness Configurable display options 22GT 250 cd m2 22FC 300 cd m2 19SC 450 cd m2 15FC 450 cd m2 Reading angle 22GT 178 in all directions 22...

Страница 14: ...Climatic condi tions Passive cooling no rotating parts Altitude Operating altitude max 2000 m Shock resistance 18 shocks 15 g 11 ms all axis IEC 60068 2 27 Vibration resis tance 10 150 Hz 0 075 mm 1 g...

Страница 15: ...2 IIIC T85 C Class III IECEx approval IECEx certificate Certificate in preparation IECEx marking Ex ec ic IIC T4 Gc Ex tc ic IIIC T85 C Dc Standards IEC 60079 0 2017 IEC 60079 11 2011 IEC 60079 31 20...

Страница 16: ...life at 25 C 77 F 22GT back lamp life 30 000 hrs typical half life at 25 C 77 F Interface Interface type 1x Power input w 3 pin terminal block 1x HDMI 1x DVI I 1x VGA 1x USB 1x 3 5 mm audio jack Line...

Страница 17: ...g Kits available installed in boundary wall in cabinet wall or special enclosure Mass 22GT 22FC and 19SC 6 5 kg 15FC 4 4 kg Dimensions 22 inches 567 mm x 358 mm x 68 mm 19 inches 485 7 mm x 410 5 mm x...

Страница 18: ...may be throttled IECEx marking Ex ec ic IIC T4 Gc Ex tc ic IIIC T85 C Dc Standards IEC 60079 0 2017 IEC 60079 11 2011 IEC 60079 31 2013 IEC 60079 7 2015 A1 2017 International approvals pending Note F...

Страница 19: ...uNet FLX Panel Product Description 2021 04 19 3 4 Dimensions and Nameplates Dimensions Figure 3 2 21 5 dimensions Figure 3 3 19 dimensions Figure 3 4 15 dimensions 68 567 358 68 485 7 410 5 67 434 283...

Страница 20: ...and Labels The following nameplates and labels are attached to the VisuNet FLX Panel Figure 3 5 Overview of the attached labels and nameplates 1 Main label Figure 3 6 Note For further information on t...

Страница 21: ...VisuNet FLX Panel Product Description 2021 04 21 2 Sublabel BPC3200 Figure 3 7 3 Equipotential Bonding Figure 3 8 4 Sublabel DPU3200 Figure 3 9...

Страница 22: ...stallation location with at least two persons Note Handling the VisuNet FLX components without gloves may cut fingers hands or wrists Wear gloves always during installation Caution Scratches and damag...

Страница 23: ...maged Do not expose the device to direct sunlight or other sources of light or heat Warning The use of the device is only permitted under the environmental conditions temperature humidity vibration an...

Страница 24: ...ers Avoid using the device in environments where corrosive gases are pres ent To ensure an addequate air flow from natural convection install the VisuNet FLX in a loca tion providing a minimum clearan...

Страница 25: ...to the weight of the VisuNet FLX panel especially if high levels of vibration are expected and the installation panel can move Use the brackets of the Panel Mount Kits to increase the strength of the...

Страница 26: ...The following figure shows the allowable mounting orientation for the Panel PC Figure 4 2 The Panels 21 5 19 and 15 6 can be mounted in a housing with the suitable cutout This mounting is approved fo...

Страница 27: ...1 Cut a hole in the enclosure according to the dimensions of the selected display Figure 4 3 Figure 4 4 Display Size Cutout width Cutout height Tolerance Panel Mount Kit 21 5 535 mm 21 06 in 333 5 mm...

Страница 28: ...the opening until the gasket connects smoothly to the enclosure Ensure that the gasket is properly positioned in the groove and against the panel 3 Hold on to the Panel from the front while placing t...

Страница 29: ...emplate or the dimensions shown in Figures below and mark the locations of the holes on the mounting surface 2 Securely attach the VisuNet FLX panel to the wall Ensure that the attaching hardware is i...

Страница 30: ...2021 04 30 VisuNet FLX Panel Mechanical Installation Figure 4 7 19 FLX Panel Mount Figure 4 8 15 6 FLX Panel Mount...

Страница 31: ...tial bonding Wrong or missing equipotential bonding can cause sparks This can ignite the surrounding potentially explosive atmosphere 1 Connect the equipotential bonding of the device Observe the equi...

Страница 32: ...ng PB protective equipotential bonding PB protective equipotential bonding is mandatory Warning Operator responsibility to verify PB protective equipotential bonding Check the PB protective equipotent...

Страница 33: ...he electronics which could then result in injury or damage Operate the device with a power supply that complies with SELV PELV or NEC Class 2 Warning De energize the equipment or disconnect the supply...

Страница 34: ...nnecting power to the VisuNet FLX panel Figure 5 3 Power connector is included in the delivery 2 Connect a power source to the included power connector This connector supports wire size 4 mm2 12 24 AW...

Страница 35: ...ed Make sure that no power is being applied while connecting and disconnecting cables Warning Interfaces must have a strain relief in Ex operation This can be achieved with the ATEN Locks 548400 Cauti...

Страница 36: ...uNet FLX may damage the device machine or system The warranty is void if you install spare parts that are not permitted Only original service parts from P F are allowed to be used Warning When exchang...

Страница 37: ...from the DPU and be replaced 1 Remove the panel if required Place the unit on a soft raised surface so that the front will not be damaged 2 Remove the two PB conductors 1 and 2 from the PB stud on the...

Страница 38: ...er A USB Touchscreen signal LVDS video signal and Inverter LCD backlight pins Figure 7 4 Remove connectors 1 Note Make sure to pull the side tabs of the connectors Pulling on the wires can cause the p...

Страница 39: ...ur screws that connect the computing unit to the DPU and remove the old computer unit from the DPU 6 Now the steps continue with your new device If you are exchanging a BPC3200 open the side cover fir...

Страница 40: ...to the BPC3200 Manual for further information on the serial port configuration 10 Leave the side cover of your BPC3200 open open the rear cover of your DMU3200 11 Orient the computer unit to the scre...

Страница 41: ...all the Panel from the enclosure When the Panel Mount Kit is used remove the four brackets while holding on to the panel so it might not flip over Remove the panel Place the unit on a soft raised surf...

Страница 42: ...200 4 Equipotential bonding Bolt 5 Mounting holes to fix the Hooks for System installation 6 Mounting holes for fixing the safety lines for System installation Warning It is the end user s responsibil...

Страница 43: ...manufacturer Pepperl Fuchs also tested the resistance of the sealant and the resistance of the gasket between the bezel and the housing Scale Description High touch sensitivity easy to operate the to...

Страница 44: ...tically bonded Display option 22FC with capacitive touch screen Needs to be onfigured BPC3200 Box PC BPC3200 can be individually config ured 70128304 DMU3200 22GT V1 N0 Direct Monitor Unit DMU Compati...

Страница 45: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications Printed in Germany DOCT 7136...

Отзывы: