Commissioning
2
0
2
0
-0
5
25
4.2
Parameterization Using Code Cards
During parameterization, the read head scans special code cards optically and configures the
relevant parameters. Simply hold the corresponding code cards at the correct distance in front
of the lens on the read head. The standard code cards are in the appendix.
Activating Parameterization Mode
1.
To activate the read head, hold the
"ACTIVATE"
code card in the field of view of the read
head's camera system.
After recognition of the parameterization code, the activation of the parameterization mode
is enabled by the code card "USER". The read head can still be accessed by the controller.
2.
To activate the read head, hold the
"USER"
code card in the field of view of the read head's
camera system.
Once the parameterization code has been detected, LED2 lights up green for 1 second. The
read head is now in parameterization mode.
Completing Parameterization
Place the parameterization code in the field of view of the camera module.
Once the parameterization code has been detected, LED2 lights up green for 1 second.
If the parameterization code is invalid, LED2 lights up red for 1 second.
Exiting Parameterization Mode
Now hold the
"STORE"
code in front of the read head's camera system to save the configura-
tion.
When the
"STORE"
memory code is detected, the LED2 lights up green for 1 second. The
parameterization is stored in the non-volatile memory of the read head and parameterization
mode is terminated. Parameterization of the read head is now complete. If the memory code is
not detected, LED2 lights up red for 1 second.
Note
Parameterization mode can be activated in the first five minutes after voltage connection. A
time lock disables the read head once this time has elapsed. If parameterization is required at a
later time, switch off the supply voltage to the read head and switch it back on again.
Parameterization mode can now be activated within the first five minutes. The time lock
remains inactive during the parameterization process.
Note
The second parameterization code "USER" can be activated within the first
two minutes
after the first parameterization code "ACTIVATE" has been
detected.