IQT-18GM-R4-V1-Y911215

IQT-FP-R4-V1-Y911204

Содержание IQT-18GM-R4-V1-Y911215

Страница 1: ...FACTORY AUTOMATION MANUAL IQT 18GM R4 V1 Y911215 IQT FP R4 V1 Y911204...

Страница 2: ...eneral Terms of Delivery for Products and Services of the Electrical Industry published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e...

Страница 3: ...erter 6 Installation 7 Storage and transport 7 Unpacking 7 Device connection 7 Power supply RS 485 serial connections 7 Ground connection 8 Instructions for connecting communication interface 8 Commis...

Страница 4: ......

Страница 5: ...rl Fuchs 1 IQT 18GM R4 V1 Y911215 IQT FP R4 V1 Y911204 Declaration of conformity The IDENT Control System was developed and manufactured compliant with applicable European and North American standards...

Страница 6: ...V1 Y911215 IQT FP R4 V1 Y911204 Symbols Used This symbol warns of a danger Failure to observe this warning may result in personal injury or death or property damage or destruction This symbol warns of...

Страница 7: ...tem is not ensured if the module is not used in accordance with its intended purpose The IQT read heads may only be operated by trained professionals in accordance with these operating instructions Ge...

Страница 8: ...ck Regardless of housing style the programming steps are identical for all IQT heads IQT 18GM R4 V1 Y911215 IQT FP R4 V1 Y911204 Tags 13 56 MHz frequency range inductive Tags in this frequency range o...

Страница 9: ...dual ended cables can be used without modification for both power and communication If desired the male end can be cut off and the read head can be hard wired back in the main panel Connector cables...

Страница 10: ...onnector V1 G 12M PUR ABG V1 W Length 30 m straight socket right angled connector V1 G 30M PUR ABG V1 W Length 40 m straight socket right angled connector V1 G 40M PUR ABG V1 W Length 50 m straight so...

Страница 11: ...Unpacking Take note that the contents are not damaged In case of damage inform the post office or delivery agent and notify the supplier Check the scope of delivery against your order and the deliver...

Страница 12: ...luded with the IQT FP or directly with a metal bracket The cable should be grounded at both ends Principle of the ground connection We recommend using a conductor of at least 12 AWG in size for the gr...

Страница 13: ...85 interface is connected using a 4 pin M12 connector The shielding of the cable must be attached to the connector Pinout of the M12 connector for RS 485 Example of connection of RS 485 interface to P...

Страница 14: ...on Before commissioning verify that all connections are correct After the power supply is connected the green LED must light up Device settings Devices must be configured before connecting them to the...

Страница 15: ...her you have connected an RS 485 interface The transmission rate baud rate is selected through the software see Instructions for connecting communication interface on page 8 The following transmission...

Страница 16: ...th its name part number and a version message Example 0 C P F IDENT I CR LF IQT 18GM R4 V1 Y911215 CR LF 911215 CR LF 1830635 CR LF 05 04 07 CR Note If you receive a different response communication b...

Страница 17: ...ed the result is V 56h plus E 45h gives the sum 9Bh or v 76h plus e 65h gives the sum DBh The message with checksum is then VE 9Bh ETX or ve DBh ETX If a longer message is to be transmitted there will...

Страница 18: ...ample Setting the tag type When delivered the tag type 20 is configured This tag type is used when you want the read head to automatically determine the tag type The 64 bit code is read first and the...

Страница 19: ...0 CR Otherwise 5 CR is returned to show that writing was not possible because the tag was outside the detection range status 5 You can find an overview of all status codes on page 28 The LED on the r...

Страница 20: ...mode and Enhanced mode are differentiated Single mode Each command is executed once and an immediate response is returned To use this command the tag must stop over the read head before the command is...

Страница 21: ...R4 V1 Y911215 IQT FP R4 V1 Y911204 System commands Command description Abbreviation Page Version VE 19 Change tag CT 19 Quit QU 20 Configure interface CI 20 Configuration store CS 21 Get state GS 21 R...

Страница 22: ...ct to modifications without notice Copyright Pepperl Fuchs 18 IQT 18GM R4 V1 Y911215 IQT FP R4 V1 Y911204 Writing Data Command description Abbreviation Page Single write words SW 24 Single write words...

Страница 23: ...CHCK ETX This command is used to transmit the model number and version information of the read head change tag CT Command CT TagType CHCK ETX Response Status CHCK ETX This command is used to program t...

Страница 24: ...led configure interface CI Command CI Timeout Baud CHCK ETX Response Status CHCK ETX This command is used to set the timeout and baud rate The values are stored in non volatile memory in the control u...

Страница 25: ...ontrol After the power supply is interrupted or the read head is reset the read head will execute this command automatically Mode 1 activates the mode Mode 0 deactivates the mode By default configurat...

Страница 26: ...tly one attempt is made to read a fixed code The fixed code length is exactly 8 bytes long The characters may be unprintable and are typically only evaluated by a PC PLC program enhanced buffered read...

Страница 27: ...ting at address WordAddr e g SR000001 CHCK EXT to read 01 32 bit word at address 0000 All WordAddr and WordNum parameters are in hexadecimal To read 10 32 bit words a length of 0A must be specified en...

Страница 28: ...ess WordAddr e g SL000001ABCD CHCK ETX writes abcd to address 0 on the tag Data is written in 4 byte blocks only and the string must be exactly the correct length to be executed If the command is succ...

Страница 29: ...h write attempts All WordAddr and WordNum parameters are in hexadecimal To read 10 32 bit words a length of 0A must be specified The status 05 is returned if the tag leaves the detection range or the...

Страница 30: ...R4 V1 Y911204 Special command codes single inventory read IV Command IV CHCK ETX Response Status Data CHCK ETX Status Data CHCK ETX F000 TagsRead CHCK ETX This command acts the same as the single read...

Страница 31: ...m 000d to 255d LF 1 ASCII character 10d Line feed Mode 1 ASCII character 0 configuration store off 1 configuration store on next command is stored Model type Order code of product Part no Item number...

Страница 32: ...ce Copyright Pepperl Fuchs 28 IQT 18GM R4 V1 Y911215 IQT FP R4 V1 Y911204 Error status messages Status Meaning 0 Command executed without errors Error message sent by the ID system Status Meaning 2 Sw...

Страница 33: ...and 3 LED blinking green Command is running on read write head LED amber Command successful and tag remains in front of read head Serial data corrupt Check baud rate default is 9600 but it can be chan...

Страница 34: ...Group www pepperl fuchs com Subject to modifications without notice Copyright Pepperl Fuchs 30 IQT 18GM R4 V1 Y911215 IQT FP R4 V1 Y911204 Technical data Dimensions IQT 18GM R4 V1 Y911215 dimension d...

Страница 35: ...onal voltage Ue 20 30 V DC ripple 10 SS PELV Power consumption P0 1 2 W Supply From clean power source with 5 W slow blow fuse Interface Physical RS 485 point to point connection Protocol ASCII Transf...

Страница 36: ...V DC ripple 10 SS PELV Power consumption P0 1 3 W Supply From clean power source with 5 W slow blow fuse Interface Physical RS 485 point to point connection Protocol ASCII Transfer rate 9600 Bit s de...

Страница 37: ...ead write range in air 13 56 MHz data carrier Data carrier Reading range in mm IQT 18GM R4 V1 Y911215 IQT FP R4 V1 Y911204 IQC21 30P 0 35 0 65 IQC21 50F T10 0 69 0 126 IQC21 50P 0 55 0 100 IQC21 58 0...

Страница 38: ...7 39 47 71 G 67 103 g 08 8 BS 28 40 48 72 H 68 104 h 09 9 HT 29 41 49 73 I 69 105 i 0A 10 LF 2A 42 4A 74 J 6A 106 j 0B 11 VT 2B 43 4B 75 K 6B 107 k 0C 12 FF 2C 44 4C 76 L 6C 108 l 0D 13 CR 2D 45 4D 77...

Страница 39: ......

Страница 40: ...rters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail fa info us pepperl fuchs com Asia Pacific Headquarters Pepperl Fuchs Pte Ltd Company Registration No 199003130E Singapore 1399...