F99 Fusion Inertial Measurement Unit IMU360D-F99-B20
J1939 Interface Description
201
8-0
5
21
5.5
Parameter Mode
The parameter mode uses the "Proprietary A" PGN 0x00EFnn for a peer-to-peer
communication. Therefore the PGN includes the sensor node address in the last byte.
To read and write the parameters the eight data bytes have to contain the following commands.
The written parameter values are saved permanently when the parameter mode is left. Then
the sensor starts with a complete reset and the new parameter set.
5.6
Starting Parameter Mode
To send parameters to the device and to read out the actual parameters start the parameter
Mode by using the following sequence.
*: placeholder, necessary
nn: destination address -> sensor node address
rr: source address
xx: unused, bytes optional
5.7
Reading Parameters
To read out the actual parameters use the following message.
*: placeholder, necessary
pp: the index of the parameter (see chapter "Parameter Table")
nn: destination address -> sensor node address
rr: source address
xx: unused, bytes optional
Identifier
Data Bytes
Priority PGN
Source
address
1
CMD
2
Password
3
4
5
6
7
8
*
0x00EFnn
rr
0xEB
0x55
xx xx
xx
xx
xx
xx
Table 5.5
Note!
Please note that during the device is in the parameter mode no PDOs are sent. The answer
message should be D0 (see also chapter "J1939 Interface Description", section "Answer
message").
Identifier
Data Bytes
Priority PGN
Source
address
1
CMD
2
Index
3
4
5
6
7
8
*
0x00EFnn
rr
0xE0
pp
xx xx
xx
xx
xx
xx
Table 5.6