IC-KP-B6*
Communication in "IRI-B6" mode and "IVI-B6" mode
2
011-
08
5
2
Communication in "IRI-B6" mode and "IVI-B6" mode
You can replace the control interface IRI KHD2-4HB6 and IVI-KHD2 4HB6 with
the control interface IC-KP-B6-SUBD, IC-KP-B6-2V15B or IC-KP-B6-V15B.
Operate one of these control interfaces in the operation mode
IRI-B6
or
IVI-B6
.
The commands can be found on the following pages. Details on the individual
commands and the structure of the codes you find in the manuals for the control
interface units IRI KHD2-4HB6 and IVI-KHD2 4HB6.
The modes
IRI-B6
and
IVI-B6
can be selected via the multifunctional display and
push buttons on the control interface unit (see manual for the control interface
IDENTControl).
As GSD files you can use the original GSD files of the evaluating IRI KHD2-4HB6
and IVI-KHD2 4HB6.
In order to be able to read transponders of type ICC ... or read and write
transponders of type IDC ..., you need to use read / write heads of type ISH ....
The transponder of type IMC ... are not supported.
System P
You can also operate the System P (LF with 125 kHz) in the IRI / IVI mode.
Connect the corresponding read / write heads. If you connect other read / write
heads, commands are answered with an error message. The state 4 is then
inserted into the response.
If you use the System P, the only data carrier supported is the type 03
(transponder IPC03-...). Each first data word (4 bytes) is read as a fixed code.
This data word must be written onto the transponder first, using normal write
commands.
In System P (transponder type 03) you must also adjust the mode Default Read
so that the first data word is read (see "Special commands for the transponder
IPC03" in the manual of the control interface unit IC-KP-B6 *). The addresses for
the beginning and end of the reading area are based on the absolute word
address of the transponder, not on the <WordAddr>. With the setting
“
beginning
of reading area
”
= 03h and
“
end of reading area
”
= 03h the read / write head
accurately reads the first data word on the transponder.
Since the IRI / IVI-mode only defines a 28 bit long fixed code, only the 28 least
significant bits of the first data word of the System P are masked and outputted as
a fixed code. The number format is not converted. A check for invalid values will
not occur.
Note!
Note that the timing of the control interface units IC-KP-B6 * can be different
compared to the timing of the control interface units IRI-KHD2-4HB6 and IVI-
KHD2-4HB6.