![Pepperl+Fuchs ICE1 G60L-C1-V1D Series Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/pepperl-fuchs/ice1-g60l-c1-v1d-series/ice1-g60l-c1-v1d-series_manual_1527934046.webp)
2
0
1
9
-1
0
46
ICE1-*-G60L-V1D, ICE1-*-G60L-C1-V1D
Commissioning for PROFINET
6
Commissioning for PROFINET
6.1
Preparation
The configuration and commissioning process for the modules described over the following
pages was performed using TIA Portal V14 project planning software from SIEMENS. When
using a control system from a different control system provider, please refer to the correspond-
ing documentation.
GSDML File
To configure the modules in the control system, you need a GSD file in XML format. You can
download this file from our website, https://www.pepperl-fuchs.com.
The file for the PROFINET modules is named GSDML-V2.3*-Fuchs-ICE1-yyyym-
mdd.xml. In this case,
yyyymmdd
is the issue date of the file.
Integrate the GSDML file into the TIA Portal using the GSD manager via the main menu
"Options > Manage general station description files (GSD).
”
The modules with a PROFINET
interface are subsequently available in the hardware catalog.
Figure 6.1
MAC IDs
The modules have three MAC IDs assigned when they are delivered. These are unique and
cannot be changed by the user.
SNMP
The modules support the SNMP Ethernet network protocol (Simple Network Management Pro-
tocol). The information from the network management system is displayed in accordance with
MIB-II (Management Information Base), which is defined in RFC 1213.
6.2
Configuration
The configuration and commissioning process for the modules described over the following
pages was performed using TIA Portal V14 project planning software from SIEMENS. When
using a control system from a different control system provider, please refer to the correspond-
ing documentation.
The configuration is based on the example of an ICE1-16DIO-G60L-V1D module. For other
module versions, configuration is carried out with a few minor changes.
Integration of the PROFINET-IO Module into TIA
As an example, the following is an explanation of how to configure an Ethernet IO module as a
Profinet type in the TIA portal, based on the ICE1-16DIO-G60L-C1-V1D module.
Note
To configure a module in the control system, you need a GSDML file
Содержание ICE1 G60L-C1-V1D Series
Страница 1: ...R ICE1 G60L V1D ICE1 G60L C1 V1D Fieldbus Modules with Multiprotocol Technology Manual...
Страница 56: ...2019 10 56 ICE1 G60L V1D ICE1 G60L C1 V1D Commissioning for PROFINET Figure 6 15 1 2 3...
Страница 139: ...ICE1 G60L V1D ICE1 G60L C1 V1D Firmware Update 2019 10 139 Figure 10 4...