2
0
2
1
-0
2
28
IO-Link Parameters
5.3
Standard Configuration Parameters
.1
Encoder
input mode
UInteger
(8)
40
0 = single-input
rotary encoder
1 = dual-input
rotary encoder
0
Configures the connected rotary
encoder
.2
Compensa-
tion
UInteger
(8)
32
0: on
1: off
0
Activates the speed compensa-
tion for all motor connections
.3
Counter
preset value
Integer
(32)
0
-2147483648
(0x80000000)
to
2147483647
(0x7FFFFFFF)
0
Preset value of the counter
Table 5.2
Index/
.sub
Parameter
Acc
ess Data Type Length
Bit
Off-
set Value Range
Def
ault Description
Event Configuration
120
(0x78)
Event Con-
fig
r/w
Record (1) 2 byte
Describes the configuration of an
event, see "Event Codes"
.1
Warning
(mr): Motor
mainte-
nance diag-
nosis
Boolean
0
0: deactivated
1: activated
0
Event code 0x8D01.
.2
Warning
(os): Motor
power fail
Boolean
1
0: deactivated
1: activated
0
Event code 0x8D50.
.3
Warning
(os): Power
output over-
load
Boolean
2
0: deactivated
1: activated
0
Event code 0x8D51.
.4
Warning
(os): I/O
port over-
load
Boolean
3
0: deactivated
1: activated
0
Event code 0x8D52.
Reserved
Boolean
4
–
15
0
0
Indication Configuration
127
(0x7F)
Indication
Control
r/w
Record (1) 1 byte
.1
Locator
Indication
Boolean
0
0: deactivated
-
normal indica-
tion
1: activated
-
location-
dependent
indication
0
.2
–
.8
Reserved
Boolean
0: deactivated
Table 5.3
Index/
.sub
Parameter
Acc
ess Data Type Length
Bit
Off-
set Value Range
Def
ault Description