Installation
20
13
-0
3
17
5.4.2
R/W head
You can connect either an inductive R/W head (125 kHz or 13.56 MHz) or an
inductive R/W head with electromagnetic coupling (UHF with 868 MHz) to the
IDENTControl Compact.
Compatible R/W head see chapter 4.1.1.
Connecting the R/W head
Connect the R/W head with compatible connecting cable to the socket on the top
of the enclosure via the M12 connector.
Compatible connecting cables see chapter 4.2.1.
5.4.3
Ground connection
Connect the IDENTControl Compact unit to ground via a screw on the right under
the housing.
Connecting the IDENTControl Compact to ground
Screw the ground conductor to the housing with a crimp connector.
4
3
1
2
5
+
A
-
B
1
2
3
4
5
socket at housing
read/write head
Note!
In order to guarantee safe grounding, mount the serrated washer between the
crimp connector and the housing.
Use a ground conductor lead with a cross-section of at least 4 mm
2
.
1
Housing
2
Serrated lock washer
3
Crimp connector
4
Lock screw
1
2
4
3