![Pepperl+Fuchs IC-KP-B17-AIDA1 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/pepperl-fuchs/ic-kp-b17-aida1/ic-kp-b17-aida1_manual_1527930043.webp)
Commands
2014-
02
43
* access to mixed mode instance for input/output command object
The following comparison shows the relationship between input and output instances: Input
instance = output in 50d.
A combination of the "heartbeat" and the ident status forms the output instance 112 and input
instance 162. Refer to appendix B for a more detailed view of the object model.
7.4.9
Access administration
The assembly object is a collection of attributes from classes 64h and 65h (input and output).
Both implicit and explicit access to these objects is possible (via the assembly object).
Simultaneous access is regulated as follows to prevent the attributes from overwriting one
another.
Sepa-
rated
mode
104d
154d
8
8
8
8
32 / 32
105d
155d
12
12
12
12
48 / 48
106d
156d
32
32
32
32
128 / 128
107d
157d
60
60
60
60
240 / 240
108d
158d
8
8
8
8
8
40 / 40
109d
159d
12
12
12
12
8
56 / 56
110d
160d
32
32
32
32
8
136 / 136
111d
161d
60
60
60
60
8
248 / 248
112d
162d
0 / 10
0 / 10
Output
instance
Input
instance
Channel size
Required/
Generated size
Output/Input
byte
1
2
3
4
5
(conf.)
Implicit data exchange
Explicit access
Instances from input/output commands
Output
instance
Input
instance
1
2
3
4
5
(conf.)
6
Mixed
mode
100d
150d
x
x
x
x
x
x
101d
151d
x
x
x
x
x
x
102d
152d
x
x
x
x
x
x
103d
153d
x
x
x
x
x
x
Sepa-
rated
mode
104d
154d
x
x
x
x
x
105d
155d
x
x
x
x
x
106d
156d
x
x
x
x
x
107d
157d
x
x
x
x
x
108d
158d
x
x
x
x
x
x
109d
159d
x
x
x
x
x
x
110d
160d
x
x
x
x
x
x
111d
161d
x
x
x
x
x
x
112d
162d
x
Table 7.18
Access management for simultaneous access