Troubleshooting
2014-
02
103
10
Troubleshooting
10.1
Fault/Status messages
Error messages which triggered the identification system
Error messages sent by the bus connection
Status
Meaning
00h
The command has been executed without error.
FFh
The command is processing.
Status
Meaning
01h
The battery of the read/write tag is weak.
02h
Reserved
03h
Reserved
04h
Incorrect or incomplete command or parameter not in the valid range.
05h
No data carrier in the detection range.
06h
Hardware error, e.g. error during self-test or R/W head defect.
07h
Internal device error.
08h
Reserved
09h
The parameterized tag type is not compatible with the connected reading head.
0Ah
Several tags in the detection range (UHF).
0Bh
Reserved
0Ch
Reserved
0Dh
Reserved
0Eh
Internal buffer overflow.
0Fh
Reserved
Status
Meaning
10h
Reserved
20h
Reserved
40h
Incorrect or incomplete command or parameter not in the valid range.
TCP/IP: The specified length of the message does not match the actual length.