Pepperl+Fuchs ENI58PL-R Series Скачать руководство пользователя страница 1

ENI58PL-S***, ENI58PL-R***

Programming via IO-Link

FACTORY AUTOMATION

MANUAL

Содержание ENI58PL-R Series

Страница 1: ...ENI58PL S ENI58PL R Programming via IO Link FACTORY AUTOMATION MANUAL ...

Страница 2: ...ms of Delivery for Products and Services of the Electrical Indus try published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its most recent version as well as the supplementary clause Expanded reservation of proprietorship ENI58PL S ENI58PL R ...

Страница 3: ...Bridge 8 2 2 3 Connection Cable for Programming 9 2 2 4 Connection Cable for Normal Operation 9 3 Installation 10 3 1 Instructions for Mechanical and Electrical Installation 10 3 2 Connection for IO Link Programming 12 3 3 Connection for Normal Operation 14 4 Commissioning 15 4 1 Commissioning with IO Link in an FDT Environment 15 4 2 Commissioning using IO Link and the SmartBridge 17 5 IO Link Pr...

Страница 4: ...icable EU type examination certificate EU declaration of conformity Attestation of conformity Certificates Control drawings Instruction manual Other documents 1 2 Target Group Personnel Responsibility for planning assembly commissioning operation maintenance and dismounting lies with the plant operator Only appropriately trained and qualified personnel may carry out mounting installation commissio...

Страница 5: ... the angle of rotation or the direction of rotation by evaluating the impulse The rotary encoders from the ENI58PL product family allow the pulse count the direction of rotation and the output type to be programmed via the standardized IO Link interface The programming is carried out by integrating the device specific IODD IO Device Description into an FDT frame program or by using the Pepperl Fuc...

Страница 6: ...device against inadvertent operation In the event of repairs return the device to your local Pepperl Fuchs representative or sales office 1 6 Declaration of Conformity This product was developed and manufactured under observance of the applicable European standards and guidelines The product manufacturer Pepperl Fuchs GmbH D 68307 Mannheim has a certified quality assurance system that conforms to ...

Страница 7: ...ble potential for savings This variety of interfaces often results from having analog sensor inputs and the complex installation associated with them With the rotary encoders from the ENI58PL product family the IO Link interface is only used for programming The rotary encoders are not intended for IO Link operation Device description file IODD The device parameters are different for each device A ...

Страница 8: ... g PACTware IO Link Master02 USB USB to IO Link adapter box for controlling an IO Link sensor directly via a PC IO Link Master02 USB DTM Device type manager software for operating the IO Link Master02 USB via FDT PACTware IO Link Connection Wizard Add in for PACTware that enables automatic detection of the connected IO Link master USB and IO Link sensor also offering automatic setup of PACTware pr...

Страница 9: ...le cordset 8 pin IO Link master side M12 plug 5 pin M23 12 pin right rotating V15S G 0 5M CGR AA Rotary encoder side M23 single ended female cordset 12 pin right rotating IO Link master side M12 plug 5 pin M23 12 pin left rotating V15S G 0 5M CGR AB Rotary encoder side M23 single ended female cordset 12 pin left rotating IO Link master side M12 plug 5 pin Cable V15S G 0 6M CGR TC Rotary encoder si...

Страница 10: ...ed statuses This presents a significant risk of personal injury and property damage Warning Check electrical connections before switching on the system Check all electrical connections before switching on the system Incorrect connections present a significant risk of personal injury and property damage Incorrect connections can lead to malfunctions Caution Do not remove the rotary encoder housing ...

Страница 11: ... must not be installed in a location where they could be misused as a handle or climbing aid Do not make any alterations to the drive shaft or the housing of the rotary encoder Note For rotary encoders with solid shaft the shaft must be connected to the drive shaft on the part to be measured via a suitable coupling The coupling is required to protect the drive shaft on the rotary encoder against e...

Страница 12: ...ccording to the following table Connection for IO Link programming via IO Link master USB Signal Cable M23 connector plug 12 pin right rotating M23 connector plug 12 pin left rotating M12 x 1 connector plug 8 pin M12 x 1 connector plug 5 pin L White 10 10 1 3 L Brown 12 12 2 1 NC Green 5 5 3 2 NC Gray 8 8 5 4 NC Yellow 6 6 4 NC Pink 1 1 6 IO Link Blue 3 3 7 5 NC Red 4 4 8 NC 2 2 NC 7 7 NC 11 11 Ta...

Страница 13: ...nnect the SmartBridge to the rotary encoder using a suitable connection cable depending on the connection type of the rotary encoder 2 Connect the SmartBridge to a 24 VDC voltage source ENI58PL 24 V DC Power Supply 1 3 4 5 2 1 5 3 2 4 M12x1 M12x1 L L Q3 Q2 Q1 1 3 5 2 4 24VDC L L C Q C Q Bluetooth 1A ...

Страница 14: ...of the rotary encoder according to the following table Signal Cable M23 connector plug 12 pin right rotating M23 connector plug 12 pin left rotating M12 x 1 connector plug 8 pin M12 x 1 connector plug 5 pin GND White 10 10 1 3 Ub Brown 12 12 2 1 A Green 5 5 3 2 B Gray 8 8 5 4 A Yellow 6 6 4 B Pink 1 1 6 Z Blue 3 3 7 5 Z Red 4 4 8 NC 2 2 NC 7 7 NC 11 11 Shield Housing Housing Housing Housing Housin...

Страница 15: ...such as the IO Link master and the rotary encoder the IODD and the connection setup step by step Prerequisites for Commissioning To activate the rotary encoder via IO Link in an FDT environment proceed as follows 1 Download the necessary software components such as the IODD Interpreter DTM PACT ware IO Link Master02 USB DTM and the associated IODD for the rotary encoder from the relevant product p...

Страница 16: ...k IO Link USB master in the window and click OK to confirm The IO Link USB master is installed in the project as a device 5 Under Project click IO Link USB master 4 then click the right mouse button and select Add device from the menu that opens Figure 4 2 The window for selecting devices is displayed again with all available DTMs and IODDs 6 Select the required DTM and use OK to confirm The DTM i...

Страница 17: ...ODD file IO Link Device Description is available to download from the www pepperl fuchs com website on the product page for the relevant sensor The download is a zip file containing both the IODD and GDD files Installing and configuring the SmartBridge app and the IODD GDD 1 Open the relevant app store on your mobile device and make sure that Bluetooth is enabled 2 Search for the SmartBridge Peppe...

Страница 18: ...ssioning Figure 4 4 5 Open the SmartBridge app and select the App Settings menu 1 using the corresponding menu option Figure 4 5 6 Select Load custom IODD GDD 2 to load first the IODD and then the GDD into the app in 2 separate steps 1 2 ...

Страница 19: ...select Add GDD 5 If the files were implemented successfully they will be displayed in the menu under Local IODD and Local GDD 8 Close and reopen the SmartBridge app 3 4 5 Note To carry out the subsequent steps the SmartBridge must be supplied with power and the rotary encoder must be connected to the SmartBridge via a cordset ...

Страница 20: ... Key After the initial connection the SmartBridge app remembers the device key The user does not need to enter it again but must simply confirm it to establish the connection 1 From the menu select the SmartBridge interface you would like to use and follow any further instructions On delivery the interface name is SB_PF The user can change this To do so at a later point go to SmartBridge Settings ...

Страница 21: ... 3 Select SPECIALIST as the user role to be able to use the entire range of programming features If the authentication was successful and the rotary encoder has been detected the app will switch to Graphical View and display the various programming options ...

Страница 22: ...rom 1 to 16384 Output configuration as a TTL or HTL signal level Note The buttons under individual menu items in PACTware can be used to read write data from the rotary encoder or to enable a cyclic update of dynamic variables These features allow corresponding values to be read from the rotary encoder cyclically and written to the rotary encoder in the event of parameter changes These buttons are...

Страница 23: ...ation 2 Save the settings to the rotary encoder by clicking on Store to device 1 The data is saved to the rotary encoder As confirmation you can read out the stored data from the rotary encoder by clicking on Read from device 2 Note When the programming has been completed you can disconnect the rotary encoder from the IO Link master To use the rotary encoder in normal operation with a higher level...

Страница 24: ...aphical View in the SmartBridge app Figure 5 3 The menu can be used to program the rotary encoder for your application The following parameters are adjustable Resolution as a pulse count from 1 to 16384 Clockwise counterclockwise direction of rotation Output configuration as a TTL or HTL signal level ...

Страница 25: ...evant parameters As your settings are transferred directly to the device during live operation you do not need to save your programming separately Note When the programming has been completed you can disconnect the rotary encoder from the SmartBridge To use the rotary encoder in normal operation with a higher level control panel you must use a suitable connection cable see chapter 3 3 for the conn...

Страница 26: ...ve details of the model number and firmware version of the sensor ready if possible Checklist Fault Cause Remedy No IO Link connection to rotary encoder The C Q communication port on the sensor is not connected to the IO Link master The data connection between the PC PACTware IO Link master and the rotary encoder is not working Make sure the C Q communication port is connected to the IO Link maste...

Страница 27: ...chs GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pacific Headquarters Pepperl Fuchs Pte Ltd Company Registration No 199003130E Singapore 139942 Tel 65 67799091 E mail sales sg pepperl fuchs com DOCT 6268A 04 2019 ...