AS-i 3.0 Command Interface
Commands of the Command Interface
4.3.3.10
Command 9: „Diagnosing the Safe Link “
The SaW monitors with Safe Link create a histogram of the estimated telegram
run times for each communication partner. The run times are divided into incre-
ments of 5ms between 20 and 200ms, so that the histogram consists of 36
counters.
The monitors also run counters for Safe Link telegrams presumed to have been
lost.
You can use Command 9 to read out these values and at the same time restart
the measurement.
4.3.3.11
Commands 10 and 12:
read "Current safety monitor diagnostic"
Send buffer
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
Sub-command 26
16
2
80
16
+ node address
Tab. 4-50.
Reply buffer
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
Sub-command 26
16
2
Histogram value < 25 ms (low byte)
3
Histogram value < 25 ms (high byte)
4
Histogram value < 30 ms (low byte)
5
Histogram value < 35 ms (high byte)
…
…
72
Histogram value
≥
200 ms (low byte)
73
Histogram value
≥
200 ms (high byte)
74
Single error
75
Double error
76
Triple error
Tab. 4-51.
Information
This command is only available with safety monitors, version GII "ext. mode" (in stain-
less steel housing).
See <table 4-33> for an overview of the acyclic transfer commands and the supported
monitor types.