Is
s
u
e
d
a
te
:
7
.6
.2
0
1
3
160
AS-i 3.0 Command Interface
Command Interface Examples
Example above:16-bit module at address 4
⇒
Set bit 4/byte 0:
No result because toggle bit = 0.
Setting the toggle bit:
The new list of protected slaves (LPS) is written.
request: SET_LPS
byte 1
29
hex
(SET_LPS)
byte 2
00
hex
(T = 0, master 1, single master)
byte 3
00
hex
byte 4
10
hex
(LDS byte 0)
byte 5
00
hex
(LDS byte 1)
…
…
byte 11
00
hex
(LDS byte 7)
byte 12
00
hex
Tab. 5-319.
response
byte 1
00
hex
(or old values)
byte 2
00
hex
(or old values)
…
…
byte 12
00
hex
(or old values)
Tab. 5-320.
request: SET_LPS
byte 1
29
hex
byte 2
80
hex
(T = 1, master 1, single master)
byte 3
00
hex
byte 4
10
hex
(LDS byte 0)
byte 5
00
hex
(LDS byte 1)
…
…
byte 11
00
hex
(LDS byte 7)
byte 12
00
hex
Tab. 5-321.
response
byte 1
29
hex
byte 2
80
hex
(T = 1, result = 0)
byte 3
00
hex
(or old values)
…
…
byte 12
00
hex
(or old values)
Tab. 5-322.