background image

ICA-A*-I/U-IO

IO-Link analog converter

Manual

Содержание 70128166

Страница 1: ...ICA A I U IO IO Link analog converter Manual ...

Страница 2: ...rsion as well as the supplementary clause Expanded reservation of proprietorship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs com North American Headquarters Pepperl Fuchs Inc 1600 Enterprise Parkway Twinsburg Ohio 44087 USA Phone 1 330 425 3555 E mail sales us pepperl fuchs com Asia Headquarters Pepperl Fuchs Pte Ltd P F Bu...

Страница 3: ...t Description 7 2 1 Intended Use 7 2 2 Versions 7 2 3 Dimensions 7 2 4 LED Indicators 8 2 4 1 LED 1 8 2 4 2 LED 2 9 2 5 Interfaces and Connections 10 2 6 Accessories 12 3 Installation 13 3 1 Preparing for Mounting 13 3 2 Mounting 13 3 3 Connection 14 4 Operation 15 4 1 IO Link Parameters 15 5 Maintenance 16 5 1 Servicing 16 6 Glossary and List of Abbreviations 17 ...

Страница 4: ...e EU type examination certificate EU declaration of conformity Attestation of conformity Certificates Control drawings Instruction manual Other documents 1 2 Target Group Personnel Responsibility for planning assembly commissioning operation maintenance and dismount ing lies with the plant operator Only appropriately trained and qualified personnel may carry out mounting installation com missionin...

Страница 5: ...ed in descending order as fol lows Informative Symbols Action This symbol indicates a paragraph with instructions You are prompted to perform an action or a sequence of actions Danger This symbol indicates an imminent danger Non observance will result in personal injury or death Warning This symbol indicates a possible fault or danger Non observance may cause personal injury or serious property da...

Страница 6: ...ng points Discharge volt free measuring devices for a short time Ground the measuring devices If you are modifying electrostatic sensitive devices use a grounded soldering iron Operation Maintenance Use the device only within the specified ambient and operating conditions Observe laws standards and directives applicable to the intended use and the operating loca tion Do not use the device outdoors...

Страница 7: ...ation 2 2 Versions The manual applies to the following variants Analog input I U to IO Link converter IO Link to analog output converter I U 2 3 Dimensions Figure 2 1 Caution Device interference is possible in mixed and residential areas This installation may cause radio interference in mixed and residential areas Observe the applicable standards for the mixed or residential area Take appropriate ...

Страница 8: ...simultaneously the color of LED 1 may appear orange Status Description Green Device is on status OK Green flashing 1 Hz Device supply low voltage UB 18 V Green flashing 2 Hz Device supply critical UB 12 V Green asymmetrical flashing 4 Hz 1 Hz Device supply overvoltage UB 30 V Green off No voltage supply to device Table 2 1 Note If multiple diagnostics occur at the same time the LED status is prior...

Страница 9: ... Status Description Red flashing 1 Hz Voltage specification outside the nominal output range out side the parameterizable range Red flashing 2 Hz Sensor supply overcurrent Red asymmetrical flashing 4 Hz 1 Hz Channel error Uout Usetpoint channel error Uout Usetpoint Red off OK Table 2 4 Status Description Red flashing 1 Hz Current specification outside the nominal output range out side the paramete...

Страница 10: ...r Plug type assignment IO Link M12 4 pin plug A coded 1 24 V L 2 n c 3 GND L 4 C Q Analog input M12 4 pin socket A coded 1 24 V L 2 AI 3 GND L 4 n c Table 2 7 Connection for Connector Plug type assignment IO Link M12 4 pin plug A coded 1 24 V L 2 n c 3 GND L 4 C Q Analog output M12 4 pin socket A coded 1 24 V L 2 n c 3 GND L 4 AO Table 2 8 Sensors with current output 0 4 mA 20 mA 1 24 V L 2 AI cur...

Страница 11: ...g outputs Actuators with analog input can be used depending on the adapter type Figure 2 5 ICA AO I U IO V1 Sensors with voltage output 10 0 V 10 V 1 24 V L 2 AI voltage 3 GND L 4 n c Actuators with current input 0 4 mA 20 mA 1 24 V L 2 n c 3 GND L 4 AO current 1 2 4 3 U 1 2 4 3 ...

Страница 12: ...ators with voltage input 10 0 V 10 V 1 24 V L 2 n c 3 GND L 4 AO voltage Sensors with current output 0 4 mA 20 mA 1 24 V L 2 n c 3 GND L 4 C Q 1 2 4 3 1 2 4 3 IO Link Masterport IO Link Slaveport Model code Description MHY T SPLITTER HOLDER Modular universal holder for M12 T splitter cordsets and M12 Y splitter cordsets Model code Description MH V1 SCREWDRIVER Torque screwdriver 0 6 Nm MH V1 BIT M...

Страница 13: ...g Mount the device in such a way that the LED displays of the device are visible during operation 3 2 Mounting Figure 3 1 Use an M5 screwdriver torque 2 5 Nm Danger Death or serious injury due to electric shock High electrical voltage in the machine plant When working on the device observe the five safety rules of electrical engineering Only connect supplies that provide protection against electri...

Страница 14: ...n cause property damage Use fastening screws that are appropriate for the type of mounting surface 1 IO Link Connection 2 Name plate replaceable 3 LED 1 Device status diagnostics 4 LED 2 IO Link status 5 Analog input output 3 4 1 2 5 Caution Risk of injury due to high temperatures High temperatures above 70 C can cause minor injuries and damage cables Wear thermally appropriate protective gloves U...

Страница 15: ...A A I U IO Operation 2021 11 15 4 Operation 4 1 IO Link Parameters Note All details of the IO Link parameters can be found in the IO device description for the device on our website www pepperl fuchs com ...

Страница 16: ...O Maintenance 5 Maintenance 5 1 Servicing The device bus nodes and modules are maintenance free No inspection and maintenance intervals are required for ongoing operation Replace defective bus nodes and or defective modules ...

Страница 17: ...etic compatibility EN European standard ESD Electrostatic discharge FE Functional earth IO Link Standardized communication system for connecting intelligent sensors and actuators to an automation system IP67 6 Dust proof protection against access with a wire 7 Protection against temporary immersion ISDU IO Link Indexed Service Data Unit LED Light emitting diode MTTFd Mean time to dangerous failure...

Страница 18: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications Printed in Germany DOCT 6995B ...

Отзывы: