ROUND METAL CEILING LOUDSPEAKER
Installation instructions
RCS6/FTS
Penton UK Ltd, Unit 2, Teville Industrials, Dominion Way, Worthing, West Sussex BN14 8NW
Tel: 01903 215315 Fax: 01903 215415 E-Mail: [email protected] Web: www.penton.org
“A”
“B”
1. Loosen wingnut “A”
(you will NOT have to remove the
wing nut completely)
2. If the wingnut is on e.g. your left,
slide the whole plate to the left.
3. This will disengage the retaining clip “B”
4. Lift the plate slightly @ “B” and slide
the plate right until clear of the dome.
Slide Plate
Slide Plate out
5. Wire plate
6. Re-fit plate to dome and
tighten wingnut
8. Once dome has been inserted pull
the slider knob down until it clamps to
the ceiling. Tighten the retaining knobs
to secure the dome.
9. Fitting the speaker
Compress “V” spring and fit into
the retaining ear within the dome.
Connect leads to the speaker
transformer.
10. Fit second “V” clip into second
retaining ear and gently push the
speaker up into the dome (do not
push the central perforated grille area)
the speaker will self locate into the dome.
“C”
Slide
100V COM
6W
3W
1.5W
0.75W
0.25W
Circuit Diagram
Hole cutout
RCS6FTS 200mm
Fitting the dome into a ceiling
7. Loosen the retaining knob for slider “C”
Push sliders to the top of the dome and
insert dome into pre-cut hole.
X
O O
Issue 2 May 2007