Pentair TAURUS VS Скачать руководство пользователя страница 1

AQUATIC ECO-SYSTEMS

 

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

TAURUS™ VS

VARIABLE SPEED PUMP

 

INSTALLATION AND

USER’S GUIDE

Содержание TAURUS VS

Страница 1: ...AQUATIC ECO SYSTEMS IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS TAURUS VS VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE ...

Страница 2: ...rol with External Control Inputs Connecting to External Controls Using the Supplied Low Voltage Signal for Digital Control Using an External Low Voltage Signal for Digital Control External Control Only Mode Operating the Pump Setting the Clock Using the Default Schedule Custom Schedules Speed Priorities Non External Control Operating the Pump While Running Quick Clean Priming Quick Clean Keypad Lo...

Страница 3: ...tion when installing and programming to limit pumps performance potential with old or questionable equipment Code requirements for the electrical connection differ from country to country state to state as well as local municipalities Install equipment in accordance with the current National Electrical Code and all applicable local codes and ordinances Before servicing the pump switch OFF power to...

Страница 4: ...ged from the valve and a steady stream of water appears Observe filter pressure gauge and be sure it is not higher than the pre service condition General Installation Information All work must be performed by a qualified service professional and must conform to all national state and local codes Install to provide drainage of compartment for electrical components These instructions contain informa...

Страница 5: ...consumption Reservoir size the presence of additional equipment use of sanitation chemicals and local environmental factors will impact optimal programming necessary to maximize energy conservation The integrated electronics interface controls the speed settings as well as the run durations The pump can operate at speeds ranging between 300 and 3450 RPM and will operate within the voltage range of...

Страница 6: ...minated the pump is unable to run from any type of input 4 Display Mode LED Indicators An illuminated LED indicates the information being displayed on the screen at any specific point A flashing LED indicates that the parameter is currently being edited 5 Display Button Used to toggle between the different available display modes This button is also used to set the 24 hour clock and screen resolut...

Страница 7: ... reduce friction loss and improve efficiency use short direct suction and return piping 2 Install a minimum of 5 feet 1 52 meters from the perimeterofthebodyofwater Canadianinstallations require a minimum of 9 8 feet 3 meters from the inside wall of the body of water 3 Install the pump a minimum of 3 feet 9 meters from the heater outlet 4 Donotinstallthepumpmorethan10feet 3 1meters above the water...

Страница 8: ...eallelectricalbreakersandswitchesareturned off before wiring motor Always wait five 5 minutes after disconnecting the power from the pump before opening or servicing the drive 2 Choose a wire size for the pump in accordance with thecurrentNationalElectricalCodeandallapplicable local codes and ordinances When in doubt use a heavier gauge larger diameter wire Be sure the wiring voltage is within the...

Страница 9: ... 5V signal supplied by the drive the speeds should be wired as shown in Figure 4 When there is a low voltage signal present on the Speed Digital Input line the pump will run the speed that is programmed for the speed that is being triggered The 5V signal supplied via the red wire is the suggested input for the Speed Digital Inputs See Figure 4 Note Any relay can be associated to any Digital Input ...

Страница 10: ...Control Only Mode External Control Only mode will only allow the pump to run from external controls inputs When this mode is active the programmed pump schedule is deactivated and user speed requests from the keypad will not be accepted If the pump is stopped a user can still program the speeds for all four Speed buttons 9 00Pm Figure 6 Activating External Control Only EXTERNAL LOW VOLTAGE SUPPLY ...

Страница 11: ...ime is reset the clock will stop blinking Note When power is returned to the pump after a prolonged outage 24 hours the clock will automatically set itself to the Speed 1 start time blink and advance The pump will also run the associated schedule from that start time Using the Default Schedule The default schedule is designed to provide enough daily turnover to service a typical body of water See ...

Страница 12: ...s and minutes Note The duration parameter is adjusted in 15 minute increments 8 Pressing the 1 button will continue to cycle through these parameters but the changes are immediately saved as they are adjusted 9 Press the 2 button The LED above SPEED 2 will begin to flash and the corresponding parameter LED will flash while editing 10 Use the and arrows to adjust the speed in RPM for SPEED 2 11 Pre...

Страница 13: ...ed within 10 seconds When Quick Clean is running and you wish to stop the Quick Clean prior to the duration being completed press and hold the Quick Clean button for 3 seconds and the pump will return to the appropriate point in the programmed schedule Speed Priorities Non External Control For schedule duration settings SPEEDs are prioritized in numerical order SPEED 1 SPEED 2 SPEED 3 SPEED 1 is t...

Страница 14: ...Priming Speed PrI Remaining Time Once priming has begun the speed can be adjusted between 3450 and 1700 RPM using the and arrows If it is adjusted below 1700 RPM Priming mode will be disabled and the pump will immediately begin to run the scheduled speed When priming is disabled and the pump is started from a stopped state the screen will display PrI OFF for 10 seconds while running the scheduled ...

Страница 15: ...Clean key for more than three 3 seconds will cancel Quick Clean mode Note During the Quick Clean mode the pump will not start with the priming sequence Note It is recommended that you do not set the Quick Clean duration to 0 HRS Setting the Quick Clean duration to 0 HRS will not allow you to change the duration setting while the motor is running The motor will have to be stopped in order to change...

Страница 16: ...ressing the 1 2 3 and Quick Clean buttons and cycling through all the screens Also write down the Priming Speed 3 Press and hold the 1 2 3 and Quick Clean buttons for 3 seconds 4 The screen will display FACt rSt if factory reset is successful See Figure 13 5 Be sure to reprogram the schedule and priming speed after the factory reset The pump must be turned back on with the Start Stop button before...

Страница 17: ...e the clamp and lid 4 Remove debris and rinse out the basket Replace the basket if it is cracked 5 Put the basket back into the housing Be sure to align the notch in the bottom of the basket with the rib in the bottom of the volute 6 Fill the pump pot and volute up to the inlet port with water 7 Clean the cover O ring and sealing surface of the pump pot Note It is important to keep the lid O ring ...

Страница 18: ...ture is cool to touch then open with extreme caution Be sure not to scratch or mar the polished shaft seal faces seal will leak if faces are damaged The polished and lapped faces of the seal could be damaged if not handled with care Pump Disassembly All moving parts are located in the rear sub assembly of this pump Tools required 1 4 inch socket or open end wrench 3 8 inch socket or open end wrenc...

Страница 19: ...e seal plate to the motor 3 Before installing the rotating portion of the seal on the motor shaft wet the motor shaft with soapy water and slide the seal onto the motor shaft Ensure that the carbon face contacts the ceramic face of the stationary seat Press the seal into the seal plate with your thumbs and wipe off the ceramic with a clean cloth 4 Screw impeller onto the motor shaft clockwise to t...

Страница 20: ...ee page 14 Pump Disassembly Clean debris from impeller If debris cannot be removed complete the following steps 1 Remove left hand thread anti spin bolt and o ring 2 Remove clean and reinstall impeller Reassemble see page 15 Pump Reassembly Clean suction trap Pump fails to start Mains voltage is not present Pump shaft is locked Pump shaft is damaged 1 Replace fuse reset breaker GFCI 2 Tighten main...

Страница 21: ...hen there may be a problem with the pump s rotating assembly Please disassemble the pump and investigate to see if there is a problem with the impeller or mechanical seal See page 14 Pump Disassembly for instructions for disassembling the pump 0F Absolute AC Under Voltage Detected This indicates that the supply voltage has dropped below the operating range of 99v This could be caused by normal vol...

Страница 22: ...51094 BASE 23 9 357161 DRAIN PLUG 24 10 192115 O RING DRAIN PLUG 25 11 351089 VOLUTE 26 12 357255 O RING LID 2 357 13 355667 BASKET Part No Descrip on 350091 LID SEE THROUGH 351090 CLAMP CAM AND RAMP 353110 VOLUTE ASSEMBLY INCLUDES ITEMS 9 15 072184 WASHER 3 8 IN SS 8 REQ 355621 SCREW 3 8 16 X 2 1 4 HEX HEAD 4 REQ 355334 SCREW 8 32 HEX WASHER HEAD 3 REQ 355389 SCREW IMPELLER LOCKING 354545S SEAL S...

Страница 23: ... 40ºF to 185 Operating 0ºC to 50ºC 32 F to 122 F Humidity Relative 0 to 95 non condensing 10 62 269 7 12 52 318 9 33 237 7 74 196 6 6 32 160 5 9 00 228 7 14 26 362 3 10 07 255 7 8 73 221 7 7 71 195 9 Pump Specifications 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 Total Dynamic Head in Ft of Water Volumetric Flow Rate in Gallons Per Minute Taurus VS Performance Curves ...

Страница 24: ...and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Aquatic Eco Systems Those names and brands may be the trademarks or registered trademarks of those third parties Because we are continuously improving our products and services Pentair reserves the right to change specificatio...