SHURFLO

®

 

4008 RV REVOLUTION™ By-pass pUmp

INSTALLATION & OperATION MANuAL

INSTALLATION PREPARATION

The goal of installation is to provide a 
quiet, easy-to-maintain installation with 
good flow and low backpressure. This 
can be accomplished with the following 
guidelines:

   Mount on a solid surface in an 

accessible location for strainer cleaning 
and pump maintenance.

   Use flexible high-pressure hose 

on the pump inlet and outlet [such 
as SHURFLO Kit 94-591-01]. The 
pumps ports and strainer should 

not be connected to plastic or rigid 
pipe, or the pump's normal motion 
will transmit through rigid plumbing 
causing noise, and possibly loosening 
or cracking components.

   Pump must use an adequate 50-mesh 

strainer [such as SHURFLO 255 series 
strainers].

   Use a minimum of 1/2" [13mm] 

Inner Diameter plumbing. Smaller ID 
plumbing will cause cavitation, high 
back pressure, low flow and noise. 

MOUNTING

  Mount the pump within 6 feet of the 

tank for best performance and pump 
life. The pump will pull farther, but the 
farther it pulls the more work it does, 
increasing vibration and noise, and 
reducing the output and pump life.

  Mount pump in a space of at least 1 

cubic foot for adequate ventilation to 
prevent overheating. 

   Pump may be mounted in any position.

  Mount pump for easy access for 

cleaning strainer, maintenance and 
service.

   Mount pump on a solid surface to 

prevent vibration and noise. 

INSTALLATION GUIDELINES

  Solid Surface within 6' of tank.

  Minimize flow restrictions in the 

system.

  No Accumulator needed.

  Flexible hose on inlet and outlet.

  Minimize plumbing elbows and valves.

 

  Accessible location.

  Strainer on pump inlet.

  Properly Sized wiring.

  Properly electrical protection.

  Properly sized plumbing.

  No need for an accumulator with by-

pass pumps.

  Pump is designed for intermittent 

duty only: Do not use these pumps 
for running a Reverse-Osmosis [RO] 
Filtration System. High pressure-
continuous duty usage will shorten 
the life of the pump and is not covered 
under warranty.

   Wire Size is 16 GA MINIMUM, 12GA 

is recommended —See Wire Chart in 
Electrical Section for minimum sizing.

  Minimum power requirement is a 10 

Amp circuit.

  Reduce restrictions on inlet and 

outlet. This includes small inner 
diameter shut-off valves, winterizing 
valves and elbows.

   If the RV has an Intellitec Pump 

Controller, it must be rated at 10 or 15 
amps; If the controller is rated at 7.5 
Amps, a new controller or a high-amp 
relay must be used.

Typical Pump Installation

Содержание SHURFLO 4008 RV REVOLUTION

Страница 1: ...es increasing vibration and noise and reducing the output and pump life Mount pump in a space of at least 1 cubic foot for adequate ventilation to prevent overheating Pump may be mounted in any position Mount pump for easy access for cleaning strainer maintenance and service Mount pump on a solid surface to prevent vibration and noise INSTALLATION GUIDELINES Solid Surface within 6 of tank Minimize...

Страница 2: ...the bleach solution into the tank and fill the tank with potable water Rock the RV back and forth to coat top and sides of potable water tank 4 Open all faucets Hot Cold al lowing the water to run until the odor of chlorine is detected Allow four 4 hours of contact time to disinfect com pletely Doubling the solution concentra tion allows for a contact time of one 1 hour 5 Drain the tank Refill the...

Страница 3: ...For seized or locked diaphragm as sembly water frozen WILL NOT PRIME SPUTTERS No discharge Motor runs Is the strainer clogged with debris Is there water in the tank or has air collected in the hot water heater Is the inlet tubing plumbing suck ing in air at plumbing connections vacuum leak Is inlet outlet plumbing severely restricted or kinked Restrictive valves Proper voltage with the pump oper a...

Страница 4: ...4 ...

Страница 5: ... pour assurer une ventilation adéquate et éviter une surchauffe La pompe peut être montée dans n importe quelle position Montez la pompe de façon à faciliter l accès pour le nettoyage du filtre la maintenance et les réparations Instructions d installation Surface solide à 2 m 6 ft du réservoir Minimiser les restrictions de débit dans le circuit Pas d accumulateur nécessaire Tuyau flexible sur l ad...

Страница 6: ...ouez le véhicule d avant en ar rière afin de recouvrir le haut et les côtés du réservoir d eau potable 4 Ouvrez tous les robinets d eau chaude et d eau froide et laisser l eau couler jusqu à ce qu une odeur de chlore se fasse sentir At tendez quatre 4 heures de durée de contact pour une désinfection complète Si la concen tration de la solution est doublée attendez une durée de contact d une 1 heur...

Страница 7: ...is Y a t il de l eau dans le réservoir ou est ce que de l air s est accumulé dans le chauffe eau Est ce que la tubulure plomberie d admission aspire de l air au raccord prise d air Est ce que la plomberie d admission de sortie est sévèrement restreinte ou coudée Vannes de restriction Tension correcte avec la pompe fonction nant 10 Pour des débris dans les vannes d admission de sortie de la pompe o...

Страница 8: ...wned by Pentair Inc All other brand or product names are trademarks or registered marks of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer 911 1008 Rev H 12 12 Pentair Inc All Rights Reserved ...

Отзывы: