Pentair INTELLIpH Скачать руководство пользователя страница 1

INTELLIPH

®

 ACID DISPENSER Installation and User’s Guide

INTELLIPH

®

 ACID DISPENSER Installation and User’s Guide 

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

INSTALLATION  

AND  

USER’S GUIDE

INTELLIpH

® 

ACID DISPENSER SYSTEM  

 

Содержание INTELLIpH

Страница 1: ...TELLIPH ACID DISPENSER Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE INTELLIpH ACID DISPENSER SYSTE...

Страница 2: ...d Acid Manually 3 Dispense Amount 4 Superchlor Mode 5 Set Cell Output 5 Cell Status 5 History Data 5 Troubleshooting 6 How to refill the IntellipH canister 6 IntellipH Installation 7 Setting up the sy...

Страница 3: ...quipment IMPORTANT WARNINGS AND SAFETY INSTRUCTIONS Be sure that the pool or spa meets the requirements of the current National Electrical Code N E C Article 680 22 and all local codes and ordinances...

Страница 4: ...should be thoroughly cleaned before re use EYE CONTACT Flush eyes immediately with water for at least 20 minutes Seek immediate medical attention PERSONAL PROTECTION VENTILATION Use container outside...

Страница 5: ...the IntellipH controller control panel display will show a 60 minute countdown timer When the timer equals zero the pump on the canister is activated and acid is pumped into the pool s main waterline...

Страница 6: ...ntroller is powered off Less More buttons Scroll through the main menu items and adjust or change settings Use these buttons after pressing the Menu button to scroll through the main menu items Enter...

Страница 7: ...ller Dispense Amount 0 100 IntelliChlor SCG cell model Menu Button Press the MENU button to display the system choices Use the MORE or LESS button to scroll through each choice Press the ENTER button...

Страница 8: ...e this percentage or press the LESS button to lower this percentage Press the MENU key to exit this mode The new settings will be saved in memory If the water pH is low press the LESS button to decrea...

Страница 9: ...SCG In Superchlor mode the pool filter pump is not controlled by the IntellipH Controller Set Cell Output This setting controls IntelliChlor SCG sanitizer output and has a range of 0 100 The default f...

Страница 10: ...as not ready Intellichlor salinity lights scrolling indicating cell is on status check Cell communication link is down Cold Water is 52 F 12 2 C or below Check and confirm enough water flow through In...

Страница 11: ...ay will be blank which indicates no chlorine is being produced The IntellipH dispenser will display SYSTEM OFF WILL NOT DISPENSE No acid will be dispensed during this time If the automation panel is i...

Страница 12: ...to the bottom of the IntellipH Controller 4 Plug the IntellipH Controller cord into the IntelliChlor SCG Power Center IntelliTouch or EasyTouch Control System load center where the IntelliChlor SCG ce...

Страница 13: ...drill through the pipe 3 Clean all burrs from inside and outside of the hole If necessary use fine sandpaper to remove the burrs Install the Saddle Clamp 1 Thread the injector fitting into the top of...

Страница 14: ...f cracked P N 522386 8 Ensure rollers spin freely 9 Note if the rollers are seized or visibly worn replace roller assembly 10 Re install roller assembly Figure 1 Figure 2 Pull lock lever tab from left...

Страница 15: ...ing cover with track and slide over tube to seat the cover in place See Figure 5 3 To lock cover in place push lock lever down on the cover while turning the vertical tab180 from right to left See Fig...

Страница 16: ...tubing is cut square and the ends are clean Do not overtighten the nuts and ensure that the pump head tube is not twisted 5 Cut enough tubing to connect the Outlet of the pump to the Injection Check...

Страница 17: ...ng through the supply injector fitting cap Connect tubing onto the acid injection fitting and tighten cap securely before turning the pump on Tube Inlet nut Do not overtighten Tube Outlet nut Do not o...

Страница 18: ...ls 20 ft 522446 1 4 Black Tubing for Chemical Injection with Labels 100 ft 1 522386 Repair Kit for Tank Mounted Pump 2 522480 Pump Tubes for Tank Mounted Pump 2 pack 3 522895 Injection Kit Includes In...

Страница 19: ...INTELLIPH ACID DISPENSER Installation and User s Guide 14 3 6 4 5 1 2 3 7 8 10 9 1 2 IntellipH Controller and Chemical Canister Replacement Parts...

Страница 20: ...n the United States and or other countries Unless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the...

Отзывы: