5. INSTALLATION
5.1 Mounting Cleanload Nexus
Cleanload Nexus must be mounted securely onto a stable base.
It should not move when the Operating Handle is turned.
Securely fit the Mounting Point (Ref. 1) to the sprayer, bench, wall
or a stand.
In all cases, ensure that the mounting point is secure and will
withstand a load of 28 kg. Slide the Mounting fitting (Ref. 3) of the
Cleanload Nexus over the Mounting Point (Ref. 1) and secure with
the Bolt (Ref. 2).
!
WARNING
When installing Cleanload Nexus, ensure that all
parts are properly connected.
The sprayer Suction Hose must not be closed off or obstructed.
Prior to installation it is recommended that the sprayer suction is
checked using a suitable vacuum gauge.
If in doubt, always consult your sprayer dealer or service agent for
advice.
Recommendations:
∙
The Cleanload Nexus Operating Handle must not be mounted
more than 130 cm above the ground or an operating platform.
∙
Cleanload Nexus should be mounted slightly above the point
that the Suction Hose enters the sprayer inductor (venturi) to
reduce filling time and improve cleaning. Avoid low points in
the Suction hose where residue could collect.
∙
Install Cleanload Nexus close to the inductor (venturi) on the
sprayer. Ensure that the Suction Hose will be long enough to
be raised where it is being used for measuring as shown in sec-
tion 5.2.
∙
!
CAUTION
If mounting Cleanload Nexus permanently on
the sprayer, ensure that it is protected against mud, dust and
impact from branches, machinery etc.
CLEANLOAD NEXUS
PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
7