Installer Manual Fleck 5812 - XTR - Generalities

Ref. MKT-IM-019 / E - 14.10.2019

7 / 132

1.

Generalities

1.1. 

Scope of the documentation

The documentation provides the necessary information for appropriate use of the product. It informs

 

the user to ensure efficient execution of the installation, operation or maintenance procedures.
The content of this document is based on the information available at the time of publication. The

 

original version of the document was written in English.
For safety and environmental protection reasons, the safety instructions given in this documentation

 

must be strictly followed.
This manual is a reference and will not include every system installation situation. The person

 

installing this equipment should have:

training in the Fleck series, XTR controllers and water softener installation;

knowledge of water conditioning and how to determine proper controller settings;

basic plumbing skills.

This document is available in other languages on www.pentairaquaeurope.com/product-finder/
product-type/control-valves.

1.2. Release 

management

1.3. Manufacturer 

identifier, 

product

Manufacturer:

Pentair International LLC
Avenue de Sevelin 18
1004 Lausanne
Switzerland

Product:

Fleck 5812 - XTR

1.4. Intended 

use

The device is intended to be used for residential, commercial and light industrial applications only and

 

it is purpose-built for water treatment.

Revision

Date

Authors

Description

A

10.11.2017

BRY/ARE

First edition.

B

09.01.2018

BRY/FLA

Corrections on chlorine generation.

C

23.02.2018

BRY/ARE

Part numbers actualisation.

D

13.07.2018

BRY/FIM

Address change, Bleam information and valve on 

tank assembly.

E

14.10.2019

BRY

Maintenance plan.

Содержание FLECK 5812 XTR

Страница 1: ...INSTALLER MANUAL WATER PURIFICATION FLECK 5812 XTR...

Страница 2: ...Personnel 12 2 3 2 Material 12 2 4 Hygiene and sanitization 12 2 4 1 Sanitary issues 12 2 4 2 Hygiene measures 13 3 Description 14 3 1 Technical specifications 14 3 1 1 Performance flow rate character...

Страница 3: ...2 4 Valve configuration 36 4 2 5 Cycle time calculation 37 4 3 Salt amount definition 39 4 4 1650 Injector flow rates 40 5 Installation 43 5 1 Warnings 43 5 2 Safety notices for installation 43 5 3 In...

Страница 4: ...3 2 Master setting reference chart 67 6 3 3 Format screen 71 6 3 4 USB connection for field programming 72 6 3 5 Valve screen 73 6 3 6 Regeneration screen 79 6 3 7 Relay output screen 84 6 3 8 Meter s...

Страница 5: ...Valve used for softening 102 9 2 2 Valve used for filtering 104 9 3 Recommendations 105 9 3 1 Use original spare parts 105 9 3 2 Use original approved lubricants 105 9 3 3 Maintenance instructions 105...

Страница 6: ...10 2019 11 Spare parts 122 11 1 Valves list 122 11 2 Power head parts list 123 11 3 Valve parts list 124 11 4 Safety brine valve 2310 127 11 5 Drain line flow controls list 128 11 6 Bypass valve assem...

Страница 7: ...uld have training in the Fleck series XTR controllers and water softener installation knowledge of water conditioning and how to determine proper controller settings basic plumbing skills This documen...

Страница 8: ...irective 2014 35 UE Low Voltage Directive 2014 30 UE Electromagnetic compatibility 2011 65 CE Restriction of use of certain hazardous substances in electrical and electronic equipment RoHS UNIEN ISO90...

Страница 9: ...installation improper programming improper use improper operation and or maintenance leading to any kind of product damages improper or unauthorized intervention on the controller or components incorr...

Страница 10: ...aneously access to all updated information related to the product such as valve s and tanks detailed configuration manuals spare parts lists troubleshooting recommendations multi lingual videos detail...

Страница 11: ...ary replace them with new tags and put them in the same places Caution Warns of a risk of minor injury or major material damage to the device or environment Warning Warns against serious personal inju...

Страница 12: ...Caution Only qualified and professional personnel based on their training experience and instruction as well as their knowledge of the regulations the safety rules and operations performed are author...

Страница 13: ...aintenance It should also be repeated whenever the system remains idle for a significant time 2 4 2 Hygiene measures Disinfection The materials used for the construction of our products meet the stand...

Страница 14: ...flow Filter Continuous p 1 03 bar 9 8 m3 h 8 9 m3 h 8 4 m3 h Peak p 1 72 bar 12 7 m3 h 11 6 m3 h 10 7 m3 h Cv 11 2 gpm 10 1 gpm 9 4 gpm Kv 9 7 m3 h 8 7 m3 h 8 1 m3 h Maximum backwash p 1 72 bar 7 5 m3...

Страница 15: ...be limited in duration and in frequency Environmental conditions Indoor use only temperature from 0 C to 52 C maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relativ...

Страница 16: ...leck 5812 XTR Description 16 132 Ref MKT IM 019 E 14 10 2019 BASE 2 5 Filter Upflow Flow rate m 3 h Pressure drop bar BASE 4 Flow rate m 3 h Pressure drop bar FLOW RATE VS PRESSURE DROP Downflow Filte...

Страница 17: ...Installer Manual Fleck 5812 XTR Description Ref MKT IM 019 E 14 10 2019 17 132 3 2 Outline drawing 3 2 1 Base 2 5...

Страница 18: ...Installer Manual Fleck 5812 XTR Description 18 132 Ref MKT IM 019 E 14 10 2019 3 2 2 Base 4...

Страница 19: ...T IM 019 E 14 10 2019 19 132 3 3 Description and components location LCD screen Brine line Injector block Drain line Piston Outlet Mixing device Inlet Meter Brine valve Controller Not included in case...

Страница 20: ...drain while the media bed is remixed Brine draw slow rinse cycle C2 The controller directs water through the brine injector and brine is drawn from the brine tank The brine is then directed down throu...

Страница 21: ...om brine tank C2 BRINE DRAW SLOW RINSE C1 BACKWASH SERVICE NORMAL USE C4 BRINE REFILL Valve SERVICE NORMAL USE C3 RAPID RINSE Outlet Drain Inlet Valve Outlet Inlet Valve Outlet Inlet Valve Outlet Inle...

Страница 22: ...d by sodium ions and are sent to the drain The resin is regenerated during the brine cycle Then the slow rinse phase starts Backwash cycle C2 The flow of water is reversed by the valve and directed do...

Страница 23: ...om brine tank C2 BACKWASH C1 BRINE DRAW SLOW RINSE SERVICE NORMAL USE C4 BRINE REFILL Valve SERVICE NORMAL USE C3 RAPID RINSE Outlet Drain Inlet Valve Outlet Inlet Valve Outlet Inlet Valve Outlet Inle...

Страница 24: ...the valve comes back in to service position and stays as long as needed for brine saturation Brine draw slow rinse cycle C3 The valve directs water through the brine injector and brine is drawn from t...

Страница 25: ...2 To brine tank C2 SERVICE C1 BRINE REFIL SERVICE NORMAL USE C4 BACKWASH Valve C5 RAPID RINSE C3 BRINE DRAW SLOW RINSE Outlet Drain Inlet Valve Outlet Inlet Valve Outlet Inlet Valve Outlet Inlet Valve...

Страница 26: ...tube The water is filtered as it passes through the media Backwash cycle C1 The flow of water is reversed by the valve and directed down through the riser tube and up through the media During the bac...

Страница 27: ...2019 27 132 Note For illustration purpose only Always verify inlet and outlet marking on the valve C2 RAPID RINSE C1 BACKWASH SERVICE NORMAL USE Valve SERVICE NORMAL USE Outlet Inlet Valve Outlet Inle...

Страница 28: ...er hole DF and the plug in the upper hole UF 3 5 2 Upflow softener The valve is mounted with the upflow piston kit part number 61960 02 The injector is installed in the upper hole UF and the plug in t...

Страница 29: ...evice The valve can be equipped with a mixing device 1 whose function is to regulate the hardness of the water at the outlet The mixing can be set from 0 to 50 of hard water i e 0 turn 0 of hard water...

Страница 30: ...DF UF and filter pistons A time based signal see 6 3 7 Relay output screen page 84 can be programmed to give a dry contact signal used to close a shut off electro valve on the outlet during regenerati...

Страница 31: ...t water refill To set the valve to hard water refill follow the instructions below Tip Reverse above procedure steps to set the valve back to soft water refill No Operation A Using a flat screwdriver...

Страница 32: ...ons are driven under certain conditions To allow these reactions to take place make sure that the velocity is convenient during the different phases for proper ion exchange This velocity is given in t...

Страница 33: ...smaller tank size and resin volume and may lead in severe hardness leakage during the service cycle when the peak flow is reached The maximum softened water flow rate that a softener can produce is gi...

Страница 34: ...um amount of water that can be treated between two regenerations This last capacity takes into account the hardness of the water to be treated and is expressed in m3 or litres the combined capacity wh...

Страница 35: ...sin x Cresin ex with Mcapacity system mass capacity g as CaCO3 Vresin volume of resin L Cresin ex resin exchange capacity g Lresin as CaCO3 Ccapacity Vresin x Ccor resin ex with Ccapacity system combi...

Страница 36: ...n the valve has to limit the backwash flow rate to the above calculated flow rate To determine the injector size The velocities to be respected for brine draw and slow rinse are given on the resin man...

Страница 37: ...tion must be known which depends on the tank size the resin specifications for the velocity for backwashing the resin bed the velocity of water for brine draw slow rinse and fast rinse Further informa...

Страница 38: ...nse duration To calculate fast rinse duration The fast rinse is aimed at eliminating an excess of salt in the resin bed and also recompacting the resin in the tank Depending on the valve type the fast...

Страница 39: ...e time required to draw the brine take into account that the volume of brine Vbrine will be 1 125 bigger than the volume of water refilled 4 3 Salt amount definition The salt settings is done through...

Страница 40: ...0 Injector flow rates The following tables and graphics represent the injectors flow rate as a function of the inlet pressure for the different injector sizes Inlet pressure bar Flow rate l min INJECT...

Страница 41: ...tem sizing Ref MKT IM 019 E 14 10 2019 41 132 Inlet pressure bar Flow rate l min INJECTOR 0 INJECTOR 1 Inlet pressure bar Flow rate l min INJECTOR 2 Inlet pressure bar Flow rate l min Total Rinse Draw...

Страница 42: ...tem sizing 42 132 Ref MKT IM 019 E 14 10 2019 Inlet pressure bar Flow rate l min INJECTOR 3 INJECTOR 4 Inlet pressure bar Flow rate l min INJECTOR 5 Inlet pressure bar Flow rate l min Total Rinse Draw...

Страница 43: ...orming any kind of action on the device please ensure to have disconnected the transformer from the power source to shut off inlet water supply to the valve and to drain water pressure opening a tap d...

Страница 44: ...on injector of water pressure is required for the regeneration valve to operate effectively Mandatory Do not exceed a maximum of 8 6 bar inlet pressure Should this happen or be subject to happen it i...

Страница 45: ...flow rate is greater than 26 5 lpm 7 gpm or the pipe length is greater than 6 m 19 ft 8 in do not support the weight of the system on the valve fittings plumbing or the bypass it is not recommended to...

Страница 46: ...site tank will expand both vertically and circumferential In order to compensate the vertical expansion the piping connections to the valve must be flexible enough to avoid overstress on the valve and...

Страница 47: ...flexible piping failure to provide enough vertical compensation may lead to different kinds of damage either on the valve thread which connects to the tank or on the female thread connection of the t...

Страница 48: ...example Configuration example Block diagram 60067 03 26773 5812 XTR 18404 Main inlet By pass User s line Valve Meter Resin tank Check valve to prevent water harm Pressure gauge Can be integrated in t...

Страница 49: ...egeneration time after the calculated system capacity is depleted The control calculates the system capacity by dividing the unit capacity by the feed water hardness and subtracting the reserve The re...

Страница 50: ...er Manual Fleck 5812 XTR Installation 50 132 Ref MKT IM 019 E 14 10 2019 5 8 Electrical connections 12 VDC Remote lock and start Meter 12 VDC Relay auxiliary 1 Relay auxiliary 2 USB Motor and optical...

Страница 51: ...e procedures may also require that the system is bypassed Caution Do not solder pipes with lead based solder Caution Do not use tools to tighten plastic fittings Over time stress may break the connect...

Страница 52: ...or if the unit is located 6 1 12 2 m from the drain use 31 75 mm 1 tubing Use appropriate fittings to connect the 31 75 mm 1 tubing to the 25 4 mm 1 NPT drain connection on the valve The drain line ma...

Страница 53: ...malfunction power failure etc the brine tank overflow fitting will direct overflow to the drain instead of spilling on the floor This fitting should be on the side of the cabinet or brine tank Most t...

Страница 54: ...ects to the valve Make the connections and hand tighten Be sure that the brine line is secure and free from air leaks Even a small leak may cause the brine line to drain out and the softener will not...

Страница 55: ...ows you to start a regeneration and manually cycle through the regeneration steps 2 Settings Displays the settings screen which allows you to adjust commonly used settings Pressing this button while i...

Страница 56: ...with water 9 Treatment The unit is treating water 10 Day and time Displays the currently programmed day of the week and time This button will flash at the start up and if the supercapacitor is dischar...

Страница 57: ...ayed when an error has occurred accompanied with an audible alarm Press to silence the audible alarm 20 Error Displayed when an error has occurred Press to display the error screen for more detailed e...

Страница 58: ...aster settings if any button is not pressed for five minutes 26 Accept Press to save or accept changes in controller configuration 27 Cancel Press to cancel configuration and exit to previous screen w...

Страница 59: ...Date and time Time AM PM HR Day Month Year Set time and date of the controller Settings Day override Time driven OFF 1 99 days 4 8 12 16 and 20 hours Mandatory for timeclock systems Available to be pr...

Страница 60: ...n is displayed Note Happens until Assistance Name is set Press the language button and use the arrows to adjust the system s displayed language English French German Italian Spanish Dutch or Portugues...

Страница 61: ...y that the homeowner may call for system service optional To enter a letter using the keypad quickly press the keypad button the number of times that correspond with the position of the correct letter...

Страница 62: ...ll need to call for service Press to validate the selection and move to the home screen 6 2 6 Day and time screen On the home screen the flashing Day and Time button indicates that the day of the week...

Страница 63: ...yed Note The Assistance screen is also displayed automatically when the system reaches the programmed assistance interval 6 2 8 Settings screen The settings screen allows you to change basic controlle...

Страница 64: ...n has been set regeneration time will have no influence on it and regeneration will start as soon as capacity end Note Changing the hardness setting recalculates treatment volume and regeneration inte...

Страница 65: ...s please contact your professional water dealer The following is a detailed overview of settings available in Master Settings Please see 6 3 2 Master setting reference chart page 67 for the complete s...

Страница 66: ...rval See 6 2 Touchscreen controller quick start page 58 for more information about these settings Note Differently from what happens if the menu is acceded from the quick start when acceded from maste...

Страница 67: ...tion Note The controller will discard any changes and exit master settings if any button is not pressed for five minutes Screen name Parameters Values Notes Format Format Language English French Germa...

Страница 68: ...n detail on page 67 Additional Valve screen parameters are dependent upon selected regeneration type Not all parameters will be displayed Softener delayed regeneration type has four reserve options fi...

Страница 69: ...ed on average day of week s water usage Variable reserve is calculated based on previous day s water usage Volume override 1 to 999 999 999 gallons liters Only displayed when regeneration type is filt...

Страница 70: ...dle 1 25 Turbine 1 50 Paddle 1 50 Turbine 2 00 Paddle 3 00 Paddle Generic Only available when meter regeneration type is selected Select the type of meter installed with the system A generic option is...

Страница 71: ...l generation low salt must be set OFF because the chlorine cell kit managed by the XTR is not available for those valves If set ON chlorine generation together with low salt detection will be performe...

Страница 72: ...6 3 4 USB connection for field programming The XTR features a USB port that allows you to connect a PC to the controller for field programming and diagnostic parameter download Note Field programmer...

Страница 73: ...he regeneration type time clock softener metered immediate softener metered delayed filter metered immediate filter metered delayed tank sensors Note Depending of the regeneration type selected follow...

Страница 74: ...0 2019 6 3 5 1 Time clock day override time driven Adjust the number of days between regenerations regen time Adjust the regeneration time Press to save or press to return to the master settings scree...

Страница 75: ...pass to the next screen or press to return to the master settings screen without saving capacity Adjust the system capacity hardness Adjust the inlet water hardness sensor sensitivity Option not avai...

Страница 76: ...press to return to the master settings screen without saving 6 3 5 3 Softener metered delayed media volume Adjust the volume of resin salt dosage Adjust the salt dosage blfc size Adjust the BLFC size...

Страница 77: ...aster settings screen without saving day override time driven Adjust the day override regen time Adjust the regeneration time reserve Contains settings for the type of reserves fixed fixed volume week...

Страница 78: ...been selected fixed Adjust the reserve Press to save and return to the master settings screen or press to return to the master settings screen without saving If fixed volume reserve has been selected...

Страница 79: ...ster settings screen or press to return to the master settings screen without saving 6 3 6 Regeneration screen From the master settings screen press the regen button to display the regeneration screen...

Страница 80: ...e as follows backwash rapid rinse Note This option appears only if regeneration type is set to time clock or filter metered delayed or immediate custom upflow downflow filter Allows for up to 20 progr...

Страница 81: ...14 10 2019 81 132 When changing the regeneration flow warning messages may appear depending of the change done Regeneration regen flow direction changed verify that the valve has the correct piston Re...

Страница 82: ...ep type pause backwash draw rapid rinse tank refill time n Adjust the step timing Press to save and pass to the next step or press to return to the regeneration screen without saving 6 3 6 2 Custom do...

Страница 83: ...steps will be pause rapid rinse and backwash time n Adjust the step timing Press to save and pass to the next step or press to valid the last step and return to the master settings screen Pressing mo...

Страница 84: ...off when the alarm is cleared cycle based The relay will turn on when the valve moves to the specified regeneration cycle steps To program select each cycle step button for which the relay should turn...

Страница 85: ...service mainten req d Turns the relay ON when the interval between services is reached Press to save and to pass to the second relay settings screen if present or press to return to the master settin...

Страница 86: ...refill Turns the relay ON when the valve is on tank refill cycle pause Can be set with customs and variable refill brining regeneration flows Turns the relay ON when the valve is on pause Press to sa...

Страница 87: ...ngs screen Press to return to the master settings screen without saving Set the second times and press to save and to pass to the second relay settings screen if present or press to return to the mast...

Страница 88: ...ter settings screen without saving 6 3 8 Meter screen From the master settings screen press the meter button to display the meter screen Note Not available with the timeclock regeneration type meter t...

Страница 89: ...ding screen where each parameter was set Press to return to master settings 6 3 10 Water Saver Regen screen From the secondary master settings screen press the water saver regen button to display the...

Страница 90: ...ns closed for the number of seconds specified in the remote regeneration screen a regeneration will be triggered regardless of volume capacity or time remaining until the next scheduled regeneration P...

Страница 91: ...nce Press to save and to return to the master settings screen or press to return to the master settings screen without saving 6 3 13 Non factory setting After all parameters in master setting have bee...

Страница 92: ...e diagnostics button to access the diagnostics screen Press the screen navigation arrows at the upper right and left of the screen to view each diagnostic parameter Press the home button to return to...

Страница 93: ...splays the software version installed on the controller No of Regens Displays how many manually and system initiated regenerations the system has gone through since last reset Regen Interval Displays...

Страница 94: ...sword prompt screen and press to validate 6 5 Resetting the controller From the master settings screen press to display the reset screen Press the factory button to reset all controller parameters to...

Страница 95: ...til fully open position E Once the drain runs clear and the inlet manual valve fully open plug in again the XTR controller to the power source F Push on the regen button once to move the valve piston...

Страница 96: ...7 2 Sanitization 7 2 1 Disinfection of water softeners The materials of construction of the modern water softener will not support bacterial growth nor will these materials contaminate a water supply...

Страница 97: ...le chlorine is available in several forms including tablets and granules These solid materials may be used directly without dissolving before use Do not let the disinfectant stand for more than 3 hour...

Страница 98: ...uring a regeneration cycle immediately advances the valve to the next cycle step position and resumes normal step timing The button is only available when the valve is in position and the motor has st...

Страница 99: ...stem configuration settings are stored in a non volatile memory and are stored indefinitely with or without power After power outage longer than 8 hours the time of day button may flash indicating it...

Страница 100: ...wer interruptions are expected the system should be set up with a sufficient reserve capacity to compensate for regeneration delays 8 6 Remote lockout If a remote switch is connected to the remote loc...

Страница 101: ...al condition of softener filter and associated ancillaries and check for any leaks ensure valve connection to piping is made with adequate flexibility as per manufacturer instruction B Inspection of e...

Страница 102: ...k for media loss at the drain during backwash D Check to see if water runs clear at the end of the backwash cycle E Observe flow fast rinse cycle and measure pressure drop thought the filter system Pr...

Страница 103: ...r watertightness clean or replace in case of leakage Check for watertightness clean or replace in case of leakage Check for watertightness clean or replace in case of leakage Check for watertightness...

Страница 104: ...regular maintenance but only to replace it at least every 3 years Items 1 year 2 year 3 year 4 year 5 year Bypass if present contains Orings Clean Clean Clean Clean Clean replace if necessary Piston...

Страница 105: ...riginal approved lubricants P80 Emulsion lubricant water base lubricant 9 3 3 Maintenance instructions Disinfect and clean the system at least once a year or if the treated water has an off taste or a...

Страница 106: ...roller replacement No Operation A Press the cover clips 2 on each side and open the cover 1 B Press the board clips 3 and release the controller 4 C Disconnect the old controller D Connect the new con...

Страница 107: ...alve body 6 F Put the piston 8 in the higher position possible G Push forward the top plate 5 H Fix the new gearing system 4 on the top plate 5 starting form the brine valve side Note If needed push t...

Страница 108: ...Installer Manual Fleck 5812 XTR Maintenance 108 132 Ref MKT IM 019 E 14 10 2019...

Страница 109: ...e the brine valve 5 E Change the piston 3 and the seals spacers cartridge 4 Mandatory Pentair recommend always to change piston and seals spacers simultaneously Caution The larger spacer 4 is the lowe...

Страница 110: ...Installer Manual Fleck 5812 XTR Maintenance 110 132 Ref MKT IM 019 E 14 10 2019...

Страница 111: ...11 132 9 4 5 Controller motor replacement No Operation A Remove the controller see 9 4 2 Controller replacement page 106 B Disconnect the optical sensor 3 C Open the motor clips 1 and pull out the old...

Страница 112: ...rewdriver on the dedicated slot 8 C Using the injector block clip 1 remove the injector 4 Caution To avoid any damage on the injector use only the clip to remove it D Remove the screen 5 using pliers...

Страница 113: ...e controller see 9 4 2 Controller replacement page 106 B Release the optical sensor support 1 by pushing it back and up as shown C Release the optical sensor 3 from its support 1 by pressing the clips...

Страница 114: ...o Operation A Remove the BLFC clip 6 B Remove the BLFC holder 1 C Using pliers remove the grid 4 from BLFC holder 1 D Remove the BLFC 5 from the grid 4 E Clean or change the BLFC 5 and the seals 2 3 F...

Страница 115: ...132 9 4 9 Meter replacement No Operation A Remove the meter clip 1 using a flat screwdriver on the dedicated slot 2 B Remove the meter 3 using pliers C Change the meter 3 D Lubricate all seals with a...

Страница 116: ...nce 116 132 Ref MKT IM 019 E 14 10 2019 9 4 10 Encoding wheel cleaning No Operation A Remove the controller see 9 4 2 Controller replacement page 106 B With a small brush clean the encoding wheel 1 C...

Страница 117: ...2 ensuring the threads are not cross threaded C Rotate the valve 1 clockwise and freely without using force until it comes to a stop Note This stop position is considered point zero D Rotate the valv...

Страница 118: ...w hardness Brine concentration and or quantity Keep brine tank full of salt at all times Clean it yearly Salt may be bridged If using a salt grid plate ensure refill water is over it Resin fouling Cal...

Страница 119: ...rease pressure to allow injector to perform properly 1 4 bar minimum Controller not cycling Replace controller Softener fails to use salt Plugged restricted drain line Clean drain line and or flow con...

Страница 120: ...will switch to power saving mode and display the error alert button as a screen saver 10 2 Error alerts Note An error alert appears on the home screen if an error condition is detected Press the erro...

Страница 121: ...page 118 Service Interval Service Interval controller has expired From within Master Settings navigate to the Assistance Mainten Interval screen and set a new Service Interval time Memory Corruption E...

Страница 122: ...inj 1 no DLFC BLFC 0 5 gpm 2 5 adapter base 1 V5812XR 001 5812 1650 XTR DF with turbine inj 1 no DLFC BLFC 0 5 gpm 2 5 adapter base 1 V5812XR 002 5812 1650 XTR DF with turbine inj 5 no DLFC BLFC 1 gpm...

Страница 123: ...scription Packaging quantity 1 BR61957 Panel gear assembly downflow upflow 1 2 61931 03 Controller XTR assembly with logo 1 3 BR61832 00 Cover assy 5800 5810 5812 black blue 1 BR61832 01 Cover assy 58...

Страница 124: ...Installer Manual Fleck 5812 XTR Spare parts 124 132 Ref MKT IM 019 E 14 10 2019 11 3 Valve parts list...

Страница 125: ...6 40947 01 Brine valve plug 1 7 13302 01SP O ring 10 8 61959 Injector plug with o ring 2 9 28387 0 12 BLFC assembly 3 8 0 125 gpm 1 28387 0 25 BLFC assembly 3 8 0 25 gpm 1 28387 0 50 BLFC assembly 3...

Страница 126: ...5 grey 1 16 43719 Screen injector 5810 5812 1 17 40946SP Clip brine retaining 10 18 19054SP O ring 10 19 40538SP Retainer tank seal 10 20 13577 01SP O ring 560 CD distributor tube 10 21 41747 Retaine...

Страница 127: ...valve 2310 Item Part number Description Packaging quantity 1 60067 03 Safety brine valve float assembly 2310 24 2 60014SP Safety brine assembly 2310 24 3 10150SP Grommet pass rod 2300 2310 2350 50 4...

Страница 128: ...10 to 25 gpm 5812 1 61980 30to45 DLFC kit 1 1 4 BSP straight 30 to 45 gpm 5812 1 2 12085SP Flow washer 1 2 gpm 10 12086SP Flow washer 1 5 gpm 10 12087SP Flow washer 2 gpm 10 12088SP Flow washer 2 4 gp...

Страница 129: ...washer 45 gpm 1 3 61974 1 5to7 DLFC kit 1 BSP elbow 1 5 to 7 gpm 5812 1 61974 10to25 DLFC kit 1 BSP elbow 10 to 25 gpm 5812 1 61974 30 35 DLFC kit 1 BSP elbow 30 35 gpm 5812 1 Item Part number Descri...

Страница 130: ...taller Manual Fleck 5812 XTR Spare parts 130 132 Ref MKT IM 019 E 14 10 2019 11 7 CE compliance part list Item Part number Description Packaging quantity 1 18280SP Collector top 1 x 0 011 grey bayonet...

Страница 131: ...country of installation The components included in the system must be separated and recycled in a waste recycling center that conforms with the legislation in force in the country of installation This...

Страница 132: ...www pentairaquaeurope com...

Отзывы: