background image

  

www.pentairaqua.com

AUTOTROL 

460i AND 460TC CONTROL SYSTEM

INSTALLATION AND OPERATION INSTRUCTIONS

Содержание AUTOTROL 460i

Страница 1: ... www pentairaqua com AUTOTROL 460i AND 460TC CONTROL SYSTEM INSTALLATION AND OPERATION INSTRUCTIONS ...

Страница 2: ...e by the length of the power outage Most power outages are less than one minute in duration Therefore it may be months or years before the time display would require resetting If an outage of one or more hours occurs the time of day should be reset No other reprogramming is necessary Self Adjusting Reserve Reserve refers to the amount of soft water that may be needed for the next 24 hours The micr...

Страница 3: ...er million grains per gallon 17 1 Figure 2 Figure 3 Figure 4 Capacity Setting Move the upper jumper to the set of pins next to the word CAPACITY Figure 4 Press the black TIME SET Button until the correct capacity value is displayed The capacity range is 1 to 99 kilograins Refer to the salt setting chart Table 1 Return the jumper to the top set of pins next to the word TIME and replace the access d...

Страница 4: ...k TIME SET button PM hours are indicated by a light next to the letters PM on the display window NOTE The use of a small needle nose pliers will aid in moving the jumper NOTE The unit is factory set to regenerate at 2 00 a m If you prefer to have the unit regenerate at an earlier or later time simply set the current time of day accordingly e g to have the unit regenerate at 4 00 a m two hours late...

Страница 5: ...ever let the amount of salt in the brine tank be less than the amount required for the next regeneration Refer to the salt setting table Table 1 for proper salt settings To set the salt dial insert a screwdriver into the pointer knob Figure 9 and move the pointer to the proper setting NOTE To convert the salt settings from English to Metric divide by 2 2 Example 12 pound 5 5 kg of salt 2 2 Pointer...

Страница 6: ...r and reset time of day display Defective circuit board Replace timer No water flow display when water is flowing Bypass valve in bypass Shift bypass valve to not in bypass position Meter probe disconnected or not fully connected to meter housing Fully insert probe into meter housing Restricted meter turbine rotation due to foreign matter in meter Remove meter housing free up turbine and flush wit...

Страница 7: ...aking certain that correct salt dosage is used Fouled softener resin Use resin cleaner The use of resin cleaners in an unvented enclosure is not recommended Incorrect salt setting Set salt control to proper level See Salt Setting chart Incorrect hardness or capacity settings Set to correct values See Programming section Water hardness has increased Set hardness to new value See Programming section...

Страница 8: ...ks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer 1017948 REV G JL17 2017 Pentair Residential Filtration LLC All Rights Reserved For Autotrol Product Warranties visit Autotrol para las garantías de los productos vis...

Отзывы: