Pentair AQ Series Скачать руководство пользователя страница 1

Instruction  Manual

Electronic Control  Pump

ISO 9001 Certified

AQ Series

Содержание AQ Series

Страница 1: ...Instruction Manual Electronic Control Pump ISO 9001 Certified AQ Series ...

Страница 2: ...Series Conform to the following directive 2006 42 EC Machinery directive 2006 95 EC Low voltage directive 2004 108 EC EMC Electromagnetic compatibility directive Refer to the following standards EN ISO 12100 1 2003 EN ISO 12100 2 2003 ISO14121 1 2007 EN60335 1 2001 EN 809 1998 EN60335 2 41 2001 EN61000 6 2 EN61000 6 3 ...

Страница 3: ...n protection automatic reset function 1 3 Controller instruction When the pump starts to deliver water the pressure switch will sense system pressure and compare it with the preset pressure It will automatically start the pump if system pressure is lower than the preset pressure 1 4 Operation Conditions 1 Ambient temperature Max 40 C 2 Liquid temperature 4 C 40 C 3 System Pressure Max 8 5 kg cm 4 ...

Страница 4: ... mains voltage is the same as the value shown on the motor plate and that the pump is safely connected to ground earth 2 The single phase models are supplied with plug and lead and can be connected directly to the mains supply 5 Wiring diagram WARNING Risk of Electric Shock This pump is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock be c...

Страница 5: ...p to continually start and stop cycling as this will reduce the motor life 3 Cycling can occur on pressure units where there is a leak in the discharge plumbing Fig 6 Fig 7 8 Pressure switch Adjust the pressure switch setting as shown in Fig 7 Make sure the system is primed The pump is supplied with a preset pressure in the pressure switch For most applications it will be required This can be achi...

Страница 6: ...ded The pump will run for 8 seconds and stop for about 3 seconds When the cycling mode repeat for 15 times consecutively the pump will be rest for 1 hour Then it will start over the protection mode until the problem is corrected Note Above unusual pump shutdown Press Reset button to reset the pump or users may remove power plug for more than 6 seconds and reconnect again to restart if it is necess...

Страница 7: ...stem and LED FAILURE is illuminated a Leakage in the system a Poor water supply Remedy Check the system the tap etc and 1 Press it for several times 2 Consult your dealer if the problem persists Replace it Check the water supply and restart the pump by pressing the reset switch RESET Consult your dealer seconds and turn it on again If the pump doesn t start immediately it needs to replace the circ...

Страница 8: ...Phone 131 PUMP Web www southerncross pentair com A division of Pentair Flow Control Pacific Pty Ltd A B N 83 000 922 690 ...