background image

Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the
General Operating Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property 
damage! Retain instructions for future reference.

Refer to form L-4082 for General Operating and Safety Instructions and Applicable Warranty.

Form L-4087 (12/09)

Bronze Models GMBN2VA, GMBN2VA3, GMBN2VA33, GMBN3VA, GMBN3VA4, GMBN3VA43, GMBN4VA,

GMBN4VA5, GMBN4VA53, GMBN5VB, GMBN5VB6, GMBN5VB63, GMBN6VC, GMBN6VC7, GMBN6VC73

Cast Iron Models GMCV2VA, GMCV2VA3, GMCV2VA33, GMCV3VA, GMCV3VA4, GMCN3VA43, GMCV4VA,

GMCV4VA5, GMCV4VA53, GMCN5VB, GMCV5VB6, GMCV5VB63, GMCV6VC, GMCV6VC7, GMCV6VC73

SHURflo Operating Instructions, Performance,
Specifications and Parts Manual

SHURflo Heavy-Duty Cast Iron and Bronze
Rotary Close-Coupled External Gear Pumps 

Description

SHURflo self-priming, positive displacement, rotary external gear pumps provide a nearly pulseless flow. Standard models 
are mounted directly to NEMA frame AC Open Drip-Proof (ODP) motors using an easy-installation package, or as pump heads
only for custom installations. Standard safety pressure relief valve that is included can be ported internally or externally.
Single-phase motors are thermally overload protected; 3-phase ODP motors are not.

Uses:  Handle a wide range of industrial, marine, agricultural and commercial applications where non-abrasive and 
non-particulated fluids compatible with pump wet-end construction component materials are pumped.

• Capacities up to 24.8 GPM.

• Maximum pressure to 125 PSI and working casing pressure to 200 PSI.

• Max. RPM: 1725.

• Suction lift to 19.5 ft.

• Mechanical seals (Viton or Buna) with carbon on ceramic faces with engineered flush chamber for internal or external flush to

handle viscosities beyond 2000 SSU.

• Pumps with electric motors are configured to handle up to 500 SSU and 125 PSI at 1725 RPM or run at reduced speeds to 

handle a wide range of pump fluid viscosities and specific gravity up to 100,000 SSU. (Maximum torque loads are found 
in the performance chart.)

• Pumps can operate bi-directionally (reversible).

• Temperature ranges from -20° to 280° F.

• Standard adjustable pressure relief valves that can be internally or externally ported are standard.

BRONZE MODELS –

Excellent for water-based fluids. Ryton PPS (Polyphenylene Sulfide) spur gears provide quiet operation and

chemical compatibility. No metal-to-metal contact. Pumps also have 303 stainless steel shafts and carbon graphite bushings.
Buna-N mechanical seal with temperature range of -20° to 210° F. Wet-end parts are constructed from bronze, brass, Ryton PPS,
stainless steel (17-7, 303 and/or 18-8), vellumoid, graphite, carbon, ceramic, and Buna-N.

CAST IRON MODELS –

Specifically designed to be used with oil-based fluids, not to be used with water-based fluids. Pumps include

steel spur gears with steel shafts and cast iron shaft support. Viton mechanical seal has temperature range of 32° to 280° F. Wet-end
parts are constructed from cast iron, steel, stainless steel (17-7, 303 and/or 18-8), vellumoid, carbon, ceramic and Viton.

REPAIR SEALS AND OPTIONS –

Standard seals are Viton and Buna-N with carbon on ceramic faces. Standard seals can be locat-

ed in the repair parts list pages in this manual. When switching between Viton and Buna-N mechanical seals, be sure to order
the matching o-rings in the same material. These can be found in the repair parts list pages in this manual. 

Optional Close-Coupled Gear Speed Reducers are available that mount directly between pump and motor to reduce pump speed
for high viscosity or high specific gravity applications (See Appendix 2). 

NOTE:

This series of gear pumps is also available as pedestal models for custom installation. They are not equipped with motors.

WARNING:  Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in flammable
and/or explosive atmospheres. When pumping hazardous or dangerous materials, use only in a room or area designated for that

purpose. For your protection, always wear proper clothing, eye protection, etc. in case of any malfunction. For proper handling techniques
and cautions, contact your chemical supplier, insurance company and local agencies (fire dept., etc.). Failure to comply with this warning
could result in personal injury and/or property damage.

Содержание SHURflo GMBN2VA

Страница 1: ...range of pump fluid viscosities and specific gravity up to 100 000 SSU Maximum torque loads are found in the performance chart Pumps can operate bi directionally reversible Temperature ranges from 20...

Страница 2: ...Motor Mount C Cast Iron B Bronze N Buna N V Viton 2 1 4 3 3 8 4 1 2 5 3 4 6 1 A 56C B 143 145TC C 182 184TC V Pressure Relief Valve standard 1 1 3 2 1 2 3 3 4 4 1 5 11 2 6 2 7 3 Blank no code single p...

Страница 3: ...7 11 2 GMBN5VB GMCV5VB 3 4 160 900 6 6 10 8 1 2 10 6 3 4 10 5 3 4 10 4 1 10 0 1 9 4 11 2 GMBN5VB GMCV5VB 3 4 160 1200 9 3 14 3 1 2 14 2 3 4 14 1 1 13 9 11 2 13 5 11 2 12 9 2 GMBN5VB GMCV5VB 3 4 160 1...

Страница 4: ...una N 41 8 GMBN5VB6 2 ODP 143 145TC 115 230 21 2 10 6 1 1725 20mm Spline 7 8 Keyed CI 3 4 Bronze Ryton BR SS 303 SS CG Vellumoid Buna N 64 8 GMBN5VB63 2 ODP 143 145TC 230 460 6 0 3 0 3 1725 20mm Splin...

Страница 5: ...NPT female pipe thread in inches This dimension may vary due to motor manufacturer s specifications Length of motor from C face to back This dimension may vary due to motor manufacturer s specificatio...

Страница 6: ...identify which coupler you have 2 Apply anti seize compound to the entire length of the motor shaft and drive coupling spline teeth 3 If you have a Type B coupler install the rubber plug See Figure 4...

Страница 7: ...g to break pump to fail motor bearing failures etc all of which can result in property damage and or personal injury NOTE Should the pump need to be self draining the pump head should be mounted in th...

Страница 8: ...back to the tank or well downstream of the pump suction See Figure 7 10 Standard models are equipped with pressure relief valves and the pump can be run in reverse however the pressure relief valve wi...

Страница 9: ...nnect piping to one of three available seal flush ports on pump Step 5 Adjust needle valve to achieve desired flow to seal cavity recommend ed 1 to 3 GPH INTERNAL FLUSH Similar to above but internal s...

Страница 10: ...mbedding dirt in windings Oil and maintain as recom mended by motor manufacturer GENERAL Periodically check that electrical connec tions are tight Pump should be drained if placed in an area that is s...

Страница 11: ...Ref No 21 is placed on the idler shaft Ref No 23 over the woodruff key and secured by the two external retaining rings Ref No 22 d Slide idler gear and shaft assem bly into pump body Ref No 4 rotating...

Страница 12: ...43 GMCV4VA GMCV4VA5 GMCV4VA53 GMCN5VB GMCV5VB6 GMCV5VB63 GMCV6VC GMCV6VC7 GMCV6VC73 12 12 Figure 12 Repair Parts Illustration Please provide following information Model number Serial number if any Par...

Страница 13: ...7 22198 22198 1 30 Piston 303 SS 4 5 Kit Kit Kit Kit Kit 1 31 Spring 17 7 SS 4 5 Kit Kit Kit Kit Kit 1 32 O Ring Buna Std 4 Kit Kit Kit Kit Kit 1 Optional O Ring Viton 5 Kit Kit Kit Kit Kit 33 O Ring...

Страница 14: ...Optional 3 Kit Kit Kit Kit Kit 33 O Ring Viton Standard 2 Kit Kit Kit Kit Kit 1 O Ring Buna Optional 3 Kit Kit Kit Kit Kit 34 Retainer SS 21422 21422 21422 21435 21435 1 35 Cap 21421 21421 21421 2143...

Страница 15: ...mbly diagram below 1 Turn off power to pump turn off inlet and outlet valves and relieve pressure in lines 2 Allow pump to cool 3 Remove cover screws 1 cover 2 and gasket 3 Be sure to mark proper orie...

Страница 16: ...184TC to 184TC 3 0 ratio 7 43 2 875 583 56 AGR184TC900 Gear Reducer 184TC to 184TC 2 0 ratio 7 43 2 875 875 56 AGR184TC1200 Gear Reducer 184TC to 184TC 1 5 ratio 7 43 2 875 1167 56 L dimension in inch...