Carefully read and follow all safety instructions
in this manual or on pump.

This is the safety-alert.

When you see this

symbol on your pump or in this manual,

look for one of the following signal words and
be alert to the potential for personal injury.

warns about hazards that 

will

cause serious personal injury, death or major
property damage if ignored.

warns about hazards that 

can

cause serious personal injury, death or major
property damage if ignored.

warns about hazards that 

will

or

can

cause minor personal injury or property

damage if ignored.
The word 

NOTICE

indicates special instructions

which are important but not related to hazards.

To avoid serious or fatal personal injury and
possible property damage, carefully read and
follow the safety instructions.

1. 

Hazardous pressure. Under

certain conditions, submersible pumps can
develop extremely high pressure. Install a
pressure relief valve capable of passing entire
pump flow at 75 PSI (517 kPa) when using an
air over water pressure tank. Install a pressure
relief valve capable of passing entire pump
flow at 100 PSI (690 kPa) when using a pre-
charged pressure tank.

Do not allow pump, pressure tank, piping,

or any other system component containing
water to freeze. Freezing may damage system,
leading to injury or flooding. Allowing pump or
system components to freeze will void warranty.

2. 

Hazardous voltage. Can shock,

burn or cause death. To avoid dangerous or
fatal electric shock hazard, use pump only in
a water well.

Risk of dangerous or fatal elec-

trical shock. 

Do not install this pump in any

pond, river, or other open body of water that
could be used for swimming or recreation.
Do not swim, wade or play in a body of
water in which a submersible pump has
been installed.

Install, ground and wire pump according 

to local code and National Electrical Code
requirements.

Disconnect electrical power supply before
installing or servicing pump.

Make sure line voltage and frequency of

power supply match motor nameplate voltage
and frequency.
3. Install pump according to all plumbing, pump

and well code requirements.

4. Test well water for purity before using well.

Call your local health department for testing
procedure.

5. During installation, keep well covered as

much as possible to prevent leaves and foreign
matter from falling into well. Foreign objects
in well can contaminate the water and cause
serious mechanical damage to the pump.

6. Pipe joint compound can cause cracking in

plastics. Use only teflon tape when sealing
joints in plastic pipe or connecting pipe to
thermoplastic pumps.

TABLE OF CONTENTS 

Safety Instructions  . . . . . . . . . . . . . . . . . . . . . .2
Pre-Installation  . . . . . . . . . . . . . . . . . . . . . . . .2
Electrical   . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6
Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Initial Startup  . . . . . . . . . . . . . . . . . . . . . . . .6-7
Connecting to Tank/Water System . . . . . . . . . .7
Troubleshooting Guide . . . . . . . . . . . . . . .10-11
Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

PRE-INSTALLATION

Inspect pump and motor for delivery damage.
Report any damage immediately to the shipping
carrier or to your dealer.
The well driller should thoroughly develop the
well (that is, pump out all fine sand and foreign
matter) before pump is installed. See Initial 
Start-Up, Page 6.
Pump performance is based on pumping clear,
cold, liquid water with no entrained air.
Warranty is void in the following conditions:
• If pump has pumped excessive sand – exces-

sive sand can cause premature wear to pump.

• If water is corrosive.
• If entrained gas or air are present in the water

being pumped – these can reduce flow and
cause cavitation which can damage pump.

• If pump has been operated with discharge

valve closed – severe internal damage will
result.

Install pump at least 15 to 20' (4.5 to 6M) below
the lowest water level reached with pump run-
ning (lowest draw-down water level), and at
least 5' (1.5M) above the bottom of the well.

GROUNDING:

Hazardous voltage. Can shock,

burn, or cause death. Permanently ground
pump, motor and control box before connect-
ing power supply to motor.

Ground pump and motor in accordance with the
local codes and ordinances. Use a copper
ground wire at least as large as wires carrying
current to motor.
Motor is supplied with a copper ground wire. 

2

Содержание PRO-SOURCE

Страница 1: ...ran ais Pages 13 23 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 262 728 9181 Espa ol Paginas 24 36 2006 PENTAIR WATER...

Страница 2: ...mp Make sure line voltage and frequency of power supply match motor nameplate voltage and frequency 3 Install pump according to all plumbing pump and well code requirements 4 Test well water for purit...

Страница 3: ...mersible Pump Motors INSTALLATION WIRING DIAGRAMS SINGLE PHASE 3 WIRE For motors of 11 2 HP and above use magnetic starter to avoid damage to pressure switch Consult factory for wiring information See...

Страница 4: ...ortant for control box selection TABLE IV Control Box Selection 4 HP Voltage Motor No Control Box No 1 2 115 214504 28010449 1 2 230 214305 28010549 214505 3 4 230 214307 28010749 214507 1 230 214308...

Страница 5: ...the tightly wound tape is the only means of keeping water out of the splice the efficiency of the splice will depend on the care used in wrap ping the tape NOTICE For wire sizes larger than 8 7mm2 use...

Страница 6: ...otch 33 electrical tape DO NOT damage pump wires NOTICE To avoid dropping the pump down the well or damaging cable or cable splices NEVER allow pump cable to support weight of pump PUMP INSTALLATION 1...

Страница 7: ...mp and entire piping system including pressure tank from freezing Pre charged Pressure Tank Hookup See Figure 12 Page 8 for piping connections to pre charged pressure tank NOTICE Check air pre charge...

Страница 8: ...NNECT PRE CHARGED TANK PRESSURE SWITCH PRESSURE GAUGE TO HOUSE SERVICE RELIEF VALVE UNION GATE VALVE FIGURE 12 Typical Submersible Installation with Pre charged Tank Installation Cut In PSI Cut Off PS...

Страница 9: ...L DISCONNECT PRESSURE GAUGE AIR VOLUME CONTROL PRESSURE SWITCH TO HOUSE SERVICE GATE VALVE RELIEF VALVE 2 ft 6m SEE TABLE FIGURE 13 Standard Pressure Tank Installation CHECK VALVE DISTANCE TO TOP BLEE...

Страница 10: ...ore reinstalling pump Fuses blow or overload protector trips when motor is running Low or high voltage Check that line voltage is within 10 of If voltage variation is more than 10 call rated nameplate...

Страница 11: ...wire size and Install larger wire from control box to pump power supply wire size against Table III If necessary have power company raise supply Page 4 voltage Plugged intake screen Pull pump and che...

Страница 12: ...leg ambient compensated extra quick trip overload relays of recommended size are not used our warranty is void Buyer s only remedy and PENTAIR s only duty is to repair or replace defective products a...

Страница 13: ...courant d alimentation correspondent la fr quence et la tension indiqu es sur la plaque sig nal tique du moteur 3 Installer la pompe conform ment tous les codes relatifs la plomberie aux puits et aux...

Страница 14: ...les 3 fils fonctionnant sur le courant monophas de 60 Hz TABLEAU II Fusibles recommand s Moteur des pompes submersibles 2 fils fonctionnant sur le courant monophas de 60 Hz SCH MAS DE BRANCHEMENT DU C...

Страница 15: ...suppl mentaires ne sont pas importants dans le choix de la bo te de commande TABLEAU IV Choix des bo tes de commande N de N de bo tes ch Tension moteur de commande 1 2 115 214504 28010449 1 2 230 2143...

Страница 16: ...es fils NOTA Dans le cas de fils de calibre n 8 7 mm2 ou plus gros les souder plut t que d u tiliser du mastic isolant lectrique Scotchfil se reporter la Figure 4 2 pissure prot g e par un tube thermo...

Страница 17: ...ne tombe pas dans le puits et pour ne pas endommager le c ble ou les pissures du c ble NE JAMAIS laisser le c ble de la pompe supporter tout le poids de la pompe INSTALLATION DE LA POMPE 1 Si un r ser...

Страница 18: ...e r servoir sous pression contre le gel Branchement sur un r servoir sous pres sion pr charg Se reporter la Figure 12 de la page 13 pour le branchement des tuyaux sur un r servoir sous pression pr cha...

Страница 19: ...servoir pr charg D marrage en lb po 2 Arr t en lb po 2 Pression de pr charge 20 138 kPa 40 276 kPa 18 lb po 2 124 kPa 30 207 kPa 50 345 kPa 28 lb po 2 193 kPa 40 276 kPa 60 414 kPa 38 lb po 2 262 kPa...

Страница 20: ...RGE SUP RIEUR CONTENANCE DES R SERVOIRS DISTANCE 42 gallons 159 L 2 pi 0 6 m 82 gallons 310 L 3 pi 0 9 m 120 gallons 454 L 5 pi 1 4 m 220 gallons 833 L 5 pi 1 4 m 315 gallons 1 192 L 10 pi 3 0 m 525 g...

Страница 21: ...er la pompe Les fusibles fondent ou le dispositif de protection contre les surcharges se d clenche lorsque le moteur fonctionne Haute ou basse tension S assurer que la tension du courant Si la fluctua...

Страница 22: ...le calibre des fils d arriv e et le calibre du grand diam tre entre la bo te de commande et la pompe c ble descendant dans le puits en se Au besoin demander la compagnie d lectricit d aug reportant au...

Страница 23: ...thermiques d clenchement extra rapide trois pieds et temp rature ambiante compens e de la dimension recommand e ne sont pas utilis s notre garantie sera annul e Le seul recours de l acheteur et la se...

Страница 24: ...24...

Страница 25: ...la tensi n y la frecuencia que aparecen en la placa de f brica del motor 3 Instale la bomba conforme a todos los requisitos de fontaner a y de los c digos para bombas y pozos 4 Haga una prueba con el...

Страница 26: ...t n dar de 60 Hz monof sicos y trifilares y motores de bombas sumergibles de marcha por compen sador trifilares TABLA II Informaci n sobre fusibles recomen dados motores de bombas sumergibles de 60 Hz...

Страница 27: ...trol TABLA V Selecci n de la caja de control hp Voltaje Motor No Caja de control No 1 2 115 214504 28010449 1 2 230 214305 28010549 214505 3 4 230 214307 28010749 214507 1 230 214308 28010849 214508 1...

Страница 28: ...l empalme depender del cuidado que se tenga cuando se envuelva la cinta AVISO Para hilos de tama o m s grande que 8 7 mm2 use uniones soldadas en lugar de masilla Scotchfil ver Figura 4 2 Empalme term...

Страница 29: ...otch 33 NO da e los hilos de la bomba AVISO Para evitar dejar caer la bomba en el pozo o da ar el cable o los empalmes del cable NUNCA deje que el cable de la bomba soporte el peso de la bomba INSTALA...

Страница 30: ...la garant a Proteja la bomba y todo el sistema de tuber as incluyendo el tanque de presi n para que no se congelen Conexi n del tanque de presi n precargado Ver la Figura 12 p gina 31 para las conexi...

Страница 31: ...que precargado PSI de activaci n PSI de desactivaci n Presi n de precarga 20 138 kPa 40 276 kPa 18 PSI 124 kPa 30 207 kPa 50 345 kPa 28 PSI 193 kPa 40 276 kPa 60 414 kPa 38 PSI 262 kPa CASQUETE VENTIL...

Страница 32: ...IFICIO SUPERIOR DE PURGA TAMA O DEL TANQUE DISTANCIA 42 gal n 159 L 2 0 6 m 82 gal n 310 L 3 0 9 m 120 gal n 454 L 5 1 4 m 220 gal n 833 L 5 1 4 m 315 gal n 1 192 L 10 3 0 m 525 gal n 1 987 L 15 4 6 m...

Страница 33: ...cal antes de volver a instalar la bomba Los fusibles est n quemados o el protector contra sobrecarga se dispara cuando el motor est en marcha Tensi n baja o alta Verifique que la tensi n de l nea se...

Страница 34: ...o m s grande de la caja de control a hilo de entrada y el tama o del hilo de la bomba Si es necesario haga que la empresa de energ a suministro de corriente contra la Tabla III eleve la tensi n de sum...

Страница 35: ...mpensaci n ambiental y disparo extra r pido del tama o recomendado nuestra garant a quedar anulada El nico recurso del comprador y la nica obligaci n de PENTAIR ser n el de reparar o reem plazar los p...