4.  After  chamber  is  drained,

remove  hold-down  bolts  on
motor housing and lift off. Use
care in lifting as the seal failure
connecting  wire  must  be 
disconnected before hous ing is
completely  re moved.  See 
sectional drawing.

5.  The  stator  is  held  in  the 

housing  with  a  bolted-in 
retaining  ring  and  pre vent ed
from rotating by a square key.

6.  Remove the retaining ring and

socket head cap screw.

7.  After  ring  is  removed,  turn 

hous ing  upright  and  bump  on
hard wood  block.  This  should
jar the stator loose and allow it
to drop out.

8.  Thoroughly  clean  housing

before  replacing  new  stator.
Replace  sta tor  and  make  all
wire con nec tions to con nec tion
box  before  re plac ing  housing
on  pump.  See  motor  lead 
connection  drawing.  This  is
important  as  leads  must  be
tucked  behind  the  windings 
by  using  hands  up  through
rotor core.

iMPOrTANT:  Use  only  butt 
con nec tions on the wires. 
Do  not  tape  leads  as  oil  will 
de te ri o rate  the  tape  and  cause 
dam age to stator and bearings.

9.  Check  top  bearing.  If  the 

bearing  is  clean  and  does 
not  turn  rough,  bearings  can 
be  reused.  If  bear ings  are 
damaged  with  dirt  or  heat, 
they  must  be  replaced.  See 
ad di tion al  instructions  on 
re plac ing seals and bearings.

10.Replace  stator  housing  onto

seal  chamber  and  bolt  in 
place.  Be  sure  seal  failure
wires  are  con nect ed  before
housing is as sem bled.

    Be  sure  O-ring  seal  has  been 

re placed. If O-ring is nicked or
cut,  replace  with  new  ring.
This ap plies to all O-rings used
in as sem bly.

11.After all leads are reconnected

in the con nec tion box, make a
high  voltage  ground  test  on
each  wire.  The  only  wire  that
should  show  ground  is  the
green  power  lead  and  the
ground  head  in  the  aux il ia ry
control cable.

12.For  safety,  complete  pump

should  be  air  checked  under
water for leaks.

    Install  air  valve  in  plug 

opening of motor housing and
charge  housing  with  about 
10 psi of air. Be sure air is dry.
Do not use air line where water
may  be  trapped  in  the  line.
Submerge com plete unit un der
water and check for leaks.

    If  seals  were  okay,  refill  seal

cham ber  with  oil.  Lay  pump
on side for this oil filling with
oil  fill  hole  upright.  Do  not
completely fill; leave oil about
1"  below  plug  hole.  Use  only
Hydromatic  sub mers ible oil or
high  grade  trans form er  oil  in
this  chamber.  Re place  plug;
use Permatex on threads. 

13.Refill  motor  chamber  with  oil

through 

con nec tion 

box

opening. Use high grade, non-
syn thet ic  trans form er  oil  or
Hydromatic spe cial submersible
oil. Fill hous ing until oil covers
top  of  wind ings. Leave  air
space in top for expansion.

NOTE:  Oil  must  cover  top 
of stator.

replacing Seals and Bearings:

1.  Drain all oil from motor chamber

and seal chamber as described.

2.  Remove  motor  housing  as 

de scribed in re plac ing stator.

3.  Remove bolts that hold bearing

housing to volute. Lift bearing
housing  and  rotating  unit  off
and  set  assembly  on  its  side.
Remove socket head screw and
washer  at  the  impeller  end  of
the  shaft.  Hold ing  the  shaft 
stationary, re move the impeller
from  the  shaft  by  tap ping  the
end of the impeller blades.

4.  To  remove  seal  plate  take  out

sock et  head  screws  and  using
screws  in  back-off  holes,  pry
plate loose. This will also force
seal off if not already removed.

5.  Remove  snap  ring.  Pull  seal 

if  it  is  free.  If  not  free,  it 
can  be  forced  off  when  shaft 
is re moved. The labyrinth ring
must also be removed. 

6.  Set  seal  housing  in  upright 

po si tion and bump end of shaft
on  hard wood  block.  This  will
push  the  bearing  from  the
hous ing  and  will  force  upper
seal from shaft.

7.  Use  bearing  puller  to  remove 

bear ings.  Replace  with  new 
bear ings.  Press  only  on 
inner  face  of  bearing  when 
replacing.  Pressing  on  outer
face  can  damage  the  bear  ing.
Bearings  are  stan dard  size 
that  can  be  obtained  from 
any  bearing  sup ply  house 
or  can  be  obtained  from
Hydromatic  factory.

8.  

iMPOrTANT: 

Do  not  use

any  of  the  old  seal  parts.
Replace with all new seals

.

NOTE:  Any  time  seal  is 
disturbed, replace seal.

9.  Thoroughly  clean  all  castings 

be fore  re plac ing  seals.  One
grain  of  dirt  between  the  seal
faces can cause failure.

NOTE: The labyrinth ring must
be  installed  with  the  groove
facing OPE. 

Содержание HYDROMATIC H4QX

Страница 1: ...oups C D FM 02 11 Item E 03 505 Part 5625 505 1 2011 Pentair Pump Group Inc NOTE To the installer Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system Installation and Service Manual For use with product built with USEM motor Hazardous Location Motor End ...

Страница 2: ...ailure Probes All our hazardous location submersible pumps have two factory installed moisture detectors seal failure probes They are in a normally open series circuit in the seal chamber Under normal operating conditions the circuit remains open If the lower seal leaks and moisture enters this chamber the moisture would settle to the bottom of the chamber and will complete the circuit between the...

Страница 3: ... line to prevent freezing This can be done only with short discharge lines otherwise water will return to the sump and cause short cycling of the pump Making Electrical Connections All electrical wiring must be in accordance with local code and only qualified electricians should make the installations Complete wiring diagrams are included for use in making the installation All wires should be chec...

Страница 4: ...SEAL PROBES 300 VAC 20 MA POWER CORD CONTROL CORD SEE TYPICAL CONTROL CIRCUITRY BELOW M RUN LIGHT SEAL FAILURE INDICATOR D C TO SEAL PROBES IN PUMP MOTOR SEAL FAILURE RELAY LEVEL CONTROL CIRCUITRY H O A H A R OVERLOADS CAPACITORS AND OR CONTROLS SHOULD BE LOCATED OUTSIDE HAZARDOUS AREA AND ENCLOSED IN AN APPROPRIATE ENCLOSURE NOTE TYPICAL CONTROL CIRCUITRY Typical FM Only Schematics ...

Страница 5: ...Wiring Diagrams PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY 5 ...

Страница 6: ... pump cords from the rest of the system Pump cords may be disconnected at control panel on sump mounted control panels and cord assembly taken with pump CAUTiON if cord openings from sump to control panel are open gases from sump could enter panel and an explosive condition could exist Pump cords may be disconnected at pump by removing the cord and cap assembly unplugging sensor wires and removing...

Страница 7: ...complete unit under water and check for leaks If seals were okay refill seal chamber with oil Lay pump on side for this oil filling with oil fill hole upright Do not completely fill leave oil about 1 below plug hole Use only Hydromatic submersible oil or high grade transformer oil in this chamber Replace plug use Permatex on threads 13 Refill motor chamber with oil through connection box opening U...

Страница 8: ...____________________________________________ ______________________________________________ ______________________________________________ 8 10 Examine all O rings for nicks before reusing 11 Use Locktite red on socket head locking screw in end of shaft 12 Before refilling chamber with oil air test as described in replacing stator 13 Refill both chambers with oil as described in replacing stator 1...

Страница 9: ...Motor End Parts 9 ...

Страница 10: ... B7 Insulator Split Bolt B8 Oil 24709110000 24709110000 24709110000 24709110000 24709110000 24709110000 B11 Cord Cap 35 11400 083 5 11400 083 5 11400 083 5 11400 083 5 11400 084 5 11400 084 5 Connector stator to conn box B4 7 5 10 HP 7 5 10 HP 15 HP 15 HP 15 HP 15 HP 6 Pole 1150 RPM 460 3 1150 575 3 1150 200 3 1150 230 3 1150 460 3 1150 575 3 1150 Item Description B1 Connection Box 11408 001 5 114...

Страница 11: ...rd Cap 35 11400 083 5 11400 087 5 11400 087 5 11400 087 5 11400 083 5 11400 087 5 11400 087 5 B4 Connector stator to conn box B5 Connector box to cord cap B7 Insulator Split Bolt 25 HP 25 HP 30 HP 30 HP 30 HP 30 HP 40 HP 4 Pole 1750 RPM 460 3 1750 575 3 1750 200 3 1750 230 3 1750 460 3 1750 575 3 1750 200 3 1750 Item Description B1 Connection Box 11408 001 5 11408 000 5 11408 004 5 11408 005 5 114...

Страница 12: ...12 D7 1 D1 D2 D5 D3 D4 D4 D3 D5 D2 1 D7 D1 D4 D5 D2 1 D7 D1 1 D7 D1 D4 D5 D2 S6AX S4KX S6LX S4LX Wet End Parts ...

Страница 13: ...13 D2 D5 1 D7 D1 D1 D7 1 D2 D5 D4 D4 D2 D5 D3 1 D7 D1 D4 D5 D2 1 D1 D7 H4QX S4LVX S8FX S4BX Wet End Parts ...

Страница 14: ... 2594 021 2 2594 021 2 10 25 2594 007 2 10 31 11043 011 2 10 38 2594 016 2 2594 016 2 2594 016 2 10 5 2594 008 2 13694 007 2 2594 008 2 2594 008 2 13720 007 2 15151 003 2 10 85 2594 009 2 11 13692 005 2 2594 010 2 13694 005 2 2594 010 2 13720 005 2 11 25 11043 008 2 2594 011 2 11 38 2594 020 2 2594 020 2 2594 020 2 11 5 11043 001 2 2594 012 2 2594 012 2 15151 001 2 11 63 2594 018 2 11 88 2594 000 ...

Страница 15: ...__________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ _____________...

Страница 16: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 17: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 18: ...rdance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from its original installation location f if unit is used for purposes other tha...

Страница 19: ......

Страница 20: ...g Line Voltage _________________________________Actual ___________________________________ Voltage to Pumps _____________________________________Actual ___________________________________ Type of Junction Box __________________________________Manufacturer of Junction Box ______________ Are Floats Installed in Wet Well Yes No Are Floats Set to Engineer s Specs Yes No Are Floats Wired for Proper Seq...

Отзывы: