MAINTENANCE INSTRUCTIONS
67
6.5 Draining the central heating system
If the need arises to drain the system, this can be done
as follows:
Switch the system to “HEAT” mode and ignite the
boiler.
Switch off the power supply to the boiler.
Wait for the appliance to cool down.
Connect a hose to the system drain point
R
and
locate the other end of the hose in a suitable
drainage system.
Open the system drain valve (fig. 1).
Open the air vents on the radiators, starting with the
highest and moving down the system to the lowest.
When the system has been drained, close the
radiator air vents and the drain valve.
Draining the domestic hot water system
If there is a danger of freezing, the domestic hot water system should be drained. This can be done as follows:
Close the main water supply valve.
Open all the hot and cold water taps.
Drain the water from the system. Used compressed air to evacuate the pipes of any remaining water.
Use non-toxic antifreeze to protect the DHW system.
On completion, close all the previously opened taps.
Freeze Protection
Glycol must not be used in Domestic Hot Water applications.
System winterization (non-operative system)
Because it may be impossible to completely drain the boilers heating circuit, D.H.W circuit and distribution system.
Pensotti recommends the introduction of the proper type antifreeze to protect these systems from freezing damage.
System winterization (operating system)
Pensotti boilers are certified for indoor use ONLY. Proper precautions for freeze protection are
recommended for boilers and associated piping in areas where the danger of freezing exists. Do not use
automotive antifreeze. Pensotti recommends the use of inhibited glycol concentrations between 20-35%
glycol. Glycol products must be maintained properly so they do not become inactive or corrosive, consult
glycol specifications for more information.
Fig. 1
Содержание PNCC-32N
Страница 8: ...GENERAL INFORMATION 5 ...
Страница 9: ...GENERAL INFORMATION 6 ...
Страница 10: ...GENERAL INFORMATION 7 ...
Страница 11: ...GENERAL INFORMATION 8 ...
Страница 14: ...INSTALLATION INSTRUCTIONS 11 2 2 Dimensions ...
Страница 15: ...INSTALLATION INSTRUCTIONS 12 2 3 Internal parts of the boiler ...
Страница 16: ...INSTALLATION INSTRUCTIONS 13 2 5 Water circuit ...
Страница 17: ...INSTALLATION INSTRUCTIONS 14 2 5 Circulation pump head flow graph ...
Страница 35: ...INSTALLATION INSTRUCTIONS 32 ...
Страница 41: ...INSTALLATION INSTRUCTIONS 38 36 ...
Страница 43: ...INSTALLATION INSTRUCTIONS 40 ...
Страница 45: ...INSTALLATION INSTRUCTIONS 42 ...
Страница 71: ...MAINTENANCE INSTRUCTIONS 68 6 6 Wiring diagrams DIGITECH TR Printed Circuit Board MIAH403 110 V 60 hz ...
Страница 76: ...MAINTENANCE INSTRUCTIONS 73 6 10 Exploded Drawings ...
Страница 77: ...MAINTENANCE INSTRUCTIONS 74 ...
Страница 78: ...MAINTENANCE INSTRUCTIONS 75 ...
Страница 79: ...MAINTENANCE INSTRUCTIONS 76 ...
Страница 81: ...Pensotti LLC 34 Coffin Ave Brewer ME 04412 P 207 942 3636 F 207 942 3737 www pensottiboiler com ...