Hospital-grade
air purifier
— INSTRUCTION MANUAL
Rensair Instruction Manual UK v2.4 – 12pp A5 + 3mm bleed, CMYK
Страница 1: ...Hospital grade air purifier INSTRUCTION MANUAL Rensair Instruction Manual UK v2 4 12pp A5 3mm bleed CMYK ...
Страница 2: ...ng air quality To manually control the fan speed press the fan speed button to toggle between low medium high and auto 5 That s it Your Rensair air purifier is now purifying the air How to turn your Rensair air purifier off Press the power button to turn the unit off Alternatively you can use the timer function to determine when the Rensair air purifier will automatically switch off Press the time...
Страница 3: ...CONTROL PANEL AIR INLET PERFORATIONS AIR OUTLET PERFORATIONS WHEELS FOR PORTABILITY 3 ...
Страница 4: ...pre filters Pre filters should be checked for dust or dirt on a weekly basis and cleaned when necessary Remove all four filters by pressing the small clip button at the top and lifting them up If possible shake dust off outdoors Use a vacuum cleaner or dry cloth to remove finer dust If needed use mild soap and water to wash them Make sure the filters are completely dry before re inserting them 4 ...
Страница 5: ...ou need to replace the HEPA 13 filter and UVC lamp Your Rensair air purifier will automatically alert you when the parts need to be replaced via the service indicator on the display panel see page 9 Changing the HEPA 13 filter and UVC lamp is easy and can be done in five minutes Instructions on how to change the filter and lamp will be included in the box when you order your replacement parts Alte...
Страница 6: ...rticle counter automatically adjusts the airflow settings based on surrounding air quality When the air quality is good the unit will automatically switch to standby mode If the surrounding air particles increase the Rensair air purifier will automatically turn on again REMOTE CONTROL The Rensair air purifier can also be controlled by the included remote control The buttons on the remote control c...
Страница 7: ...once this time has elapsed FILTER LIFE RESET Note This function should only be used after the HEPA 13 filter and UVC lamp have been changed See cleaning and maintenance on page 4 and 5 FAN SPEED To manually control the fan speed press the fan speed button to toggle between low medium high and auto RENSAIR AIRFLOW VOLUME CUBIC METERS M HOUR NOISE LEVEL POWER USAGE Low setting 300 45dBA 160W Medium ...
Страница 8: ...ously in auto mode if the air quality is deemed unsatisfactory Fan speed indicator 1 low 2 medium 3 high UVC lamp on off indicator When Timer mode is in use the display panel will indicate the remaining run time Otherwise the panel will display the room temperature The temperature indicator displays the room temperature 8 ...
Страница 9: ...tration on the right it is time to service the unit Please visit Rensair com to order a new HEPA 13 filter and UVC lamp For instructions on how to change the HEPA 13 filter and UVC lamp go to rensair com maintenance The air indicator shows the quality of the air based on the number of particles entering the unit The fewer the bars the better 9 ...
Страница 10: ...tor to allow for different power plugs CE UKCA marked Dimensions H 77cm Ø37cm Box Dimensions H 84cm x W 43cm x D 43cm Net weight 18kg Gross Weight including box 21kg Colour White HEPA filter EU13 EN 1822 class H13 UVC lamp 18W 254nm light Length of power cord 3m 10 ...
Страница 11: ...PRE FILTER FAN UVC LAMP HEPA 13 FILTER 11 ...
Страница 12: ...rensair com Need another language Scan the QR code or visit rensair com Instructionmanual to view the instruction manual in other languages VERSION 2 4 ...