background image

Page 1

 

 

VENTILATION FAN 

MODEL  ZQ165

TM

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone 

number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being 

switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as 

a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, includ-

ing fire-rated construction codes and standards.

4.  Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent 

backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire 

Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the 

local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6.  Ducted fans must always be vented to the outdoors.
7.  Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling 

installation only).

8.  This unit must be grounded.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2.  This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS 

PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4.  Please read specification label on product for further information and requirements.

READ AND SAVE 

THESE INSTRUCTIONS

Installer: Leave this manual with 

the homeowner.

OPERATION

CLEANING & MAINTENANCE

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting 

brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the 

blower assembly (includes motor and impeller).

Use an on/off switch or speed control to operate this ventilator. See “Connect Wiring” for details. Use of speed controls other than PennBarry 
supplied models may cause a motor humming noise.

Содержание ZQ165

Страница 1: ...ling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit ceiling installation only 8 This unit must be grounded CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explo...

Страница 2: ...OOKING AREA ROOF CAP with built in damper WALL CAP with built in damper 6 IN ROUND ELBOWS 6 IN ROUND DUCT FAN HOUSING Seal gaps around housing Seal duct joints with tape Keep duct runs short INSULATION Place around and over fan housing POWER CABLE Purchase separately OR The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use ...

Страница 3: ...ing will be flush with finished surface of ceiling For 1 2 thick ceiling material position bottom of each mounting flange flush with the bottom of joist The housing mounts with four 4 screws or nails Screw or nail housing to joist through low est holes in each mounting flange then through highest holes NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole of each...

Страница 4: ...ng INSTALL MASK FINISH CEILING 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL approved connector to secure house wiring to wiring plate Connect wires as shown in wiring diagrams CONNECT WIRING SCREW WIRNG PLATE SCREW FROM PARTS BAG INSTALL GRILLE 6 Attach grille to housing Squeeze grille springs and insert them into tabs on each side of housing 7 Push g...

Отзывы: