Unpacking

Place carton in an upright position and

remove staples or use a sharp (knife

edge) tool to CAREFULLY cut or scribe

the sealing tape on both sides at the top

of the carton. Open carton flaps. Remove

any cardboard and wooden filler pieces,

as well as loose components or acces-

sories shipped with the unit.

Carefully remove the unit from the carton.

Inspect the unit for any damage that may

have occurred during transit and check

for loose, missing or damaged parts.

Installation

WARNING

To reduce the risk of fire, electrical 

shock, or injury to persons, observe 

the following:

1.  Use this unit only in the matter

intended by the manufacturer. If you

have questions, contact the manu-

facturer at the address or telephone

number listed in the warranty.

2. Before servicing or cleaning 

unit, switch power off at service

panel and lock service panel 

to prevent power from being 

switched on accidentally.

3. Installation work and electrical 

wiring must be done by a qualified

person(s) in accordance with all

applicable codes and standards,

including fire-rated construction

codes and standards.

4. Sufficient air is needed for proper

combustion and exhausting of gases

through the flue (chimney) of fuel

burning equipment to prevent back-

drafting. Follow the heating equip-

ment manufacturer’s guideline and

safety standards such as those pub-

lished by the National Fire

Protection Association (NFPA), and

the American Society for Heating,

Refrigeration and Air Conditioning

Engineers (ASHRAE), and the local

code authorities.

5. When cutting or drilling into wall 

or ceiling, do not damage electrical

wiring and other hidden utilities.

6. Ducted fans must always be 

vented to the outdoors.

7. Acceptable for use over a bathtub 

or shower when installed in a GFCI

protected branch circuit.

8. Install fan at least five feet 

(1.52m) above floor.

9. Never place a switch where it can

be reached from a tub or shower.

10. This unit must be grounded.

Operation & Maintenance Manual

Zephyr Ceiling/Wall Ventilating Fans Model Z1

Printed in the USA Jan 2005

PART #99042570

Receiving and Handling 

PennBarry fans are carefully inspected before leaving the factory. When the unit is

received, inspect the carton for any signs of tampering. Inspect the unit for any dam-

age that may have occurred during transit and check for loose, missing or damaged

parts. Mishandled units can void the warranty provisions. PennBarry is not responsible

for damages incurred during shipment.

Avoid severe jarring and/or dropping. Handle units with care to prevent damage to com-

ponents or special finishes. 

Storage

Long-term storage requires special attention. Units should be stored on a level, 

solid surface, preferably indoors. If outside storage is necessary, protect the 

units against moisture and dirt by encasing the cartons in plastic or some similar 

weatherproof material.

Figure 3: Wiring Diagram

Figure 1

Figure 2

Black

Black

120 VAC Line In

Switch or Timer

Switch Box

Receptacle

Black to

Black

Ground

White to

White

White to

White

Green to

Green or

Bare Wire

Housing

Flap

Wiring

Cover

Screwdriver

Slot

Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by
observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain
instructions for future reference.

PLEASE READ AND SAVE THESE INSTRUCTIONS.