RF-8000E Operations Manual
Chapter 2. Installation Instructions — 39
Installation Equipment
See
the following table
for a list of required installation equipment. Additional equipment may be
needed, depending on specific installation site requirements and optional accessories ordered.
Table 10, Recommended Installation Equipment
Equipment or Item
Function
Site Plan and Path Calculation documentation
To correctly configure the repeater to operate in the
microwave network.
1/8-inch small flat blade screwdriver
Used for wiring DC input power terminal blocks.
3/8-inch or ½-inch Ratchet
To drive sockets
7/16-inch socket or wrench
For repeater door clamp bolts.
Digital Voltmeter, 0 ~ 200 V
To test power connections and analog test points.
Clamp-On Current Meter or Probe, 0 ~ 100 ADC
To test power systems and loads.
Spectrum Analyzer, 10 GHz
†
For signal identification and alignment
Power Meter, Agilent (HP) 435B with 8481A Sensor*
To test RF power output.
Sweep test equipment, Anritsu SiteMaster™ S820D
To test feedlines and antennas.
Antenna-Path Alignment Test Set, Pendulum
Instruments, XL Microwave Path Align-R™ 2241
To align the antennas on path per hop.
Coax Adapters, SMA M-F RT Angle, SMA(m) to N(f)
For power measurements at SMA ports.
RF Test Jumper Cables, SMA(m), 2 ea.
For test equipment, length depends on application.
Mounting Hardware
To mount repeater and antennas.
Electrical Wiring Equipment (as needed)
To connect external systems to inputs and outputs.
Wrist Grounding Strap
To protect against static discharge.
*Equivalent substitutes may be used.
†
If necessary.
Note that the site plan and network engineering documentation is used during installation to refer to
the intended parameters of the project including gain settings, and antenna location. If necessary,
consult a network administrator for more information.
Accessory Kits
Table 11, Accessory Kit, Microwave RF Repeater
Part Number
Description
Quantity
175-0028-01
Fuse, Blade Type, 3-Ampere, DC
2
550-0158-01 Repeater
Operations
and Maintenance Manual, CD-ROM
1
090-0168-04
Amplifier, Higher Power Level 2
Per Order
Table 12, Accessory Kit, Typical Alarm Equipment
Part Number
Description
Quantity
Standard = -01, UHF = -81
091-0782-01
091-0782-81
137-0782-04
Cable Clamp Kit
2
1
137-0782-05
Connector, D-Sub 37 Pin
2
1
087-0444-01
Transducer Assy (Battery Temperature Sensor)
1
1
034-0004-01
Pressure Switch Assy (Feedline Pressure Sensor)
Per Order
Per Order
125-0001-11
Screw, PHP 12-24 x .750, S/S (Rack mounting)
4
4