— Chapter 9. Configuring the Repeater
PES1900NR Operations Manual
158
UPS Status
The
UPS Status
(Uninterruptible Power Supply status) screen monitors the optional, external Back-
Up Power Supply (BUPS).
The
Alarms
tab in this
screen (see Figure 150)
displays the alarm status of
the following alarms:
AC Fail Alarm
Input power to the BUPS
failed. The BUPS provides
40 or 80 amp-hours of
backup power (depending on
the installed BUPS type) at
the repeater site, before
shutdown. The AC source
powers the charger.
Low Battery Alarm
BUPS battery voltage is
below operating tolerances,
and cannot power any
repeater functions.
High Battery Alarm
BUPS battery voltage is above operating tolerances, and cannot power any repeater functions.
Charger Fail Alarm
The internal charger for the BUPS has failed. The BUPS cannot recharge its batteries.
UPS Summary Alarm
One or more of the BUPS alarms has triggered.
UPS Tamper Alarm
The door of the BUPS is open.
RepeaterNet Menu Commands
This section describes commands that you can run from the
menu bar, in the Repeater Main Control screen.
File Menu – RepeaterNet Craft
From the Main Control screen, open the File menu. Figure 151
shows the RepeaterNet commands in this menu.
•
Download Properties
: Configuration File -> Repeater
•
Upload Properties
: Repeater’s configuration -> Configuration File
Figure 150 UPS Status Screen,
Alarms Tab
Figure 151 RepeaterNet
Craft, File Menu