Pager Setting Tab
The
Pager Setting
tab sets the RepeaterNet software, so that it sends out a page when an alarm
occurs. It also assigns a specified severity level to the alarm. Table 41 describes the Alarm Severity
settings.
RepeaterNet generates a page if the summary alarm severity is greater than or equal to the selected
Minimum Severity
setting. When RepeaterNet detects a page request, the repeater terminates any
current modem connection, and generates a page. The page format consists of the repeater number,
followed by the severity level.
For example:
123456-2
where
123456
is the repeater number, and
2
is the severity level of the alarm.
If RepeaterNet detects a change in the current alarm severity, it does the following:
•
If you set the
Minimum Severity
to
Major
, then, the RepeaterNet software generates a page
with a severity of
2
.
•
If the RepeaterNet software then detects a
Critical
alarm, it generates a new page with a
severity of
3
.
•
If you clear the
Major
alarm, but the
Critical
alarm remains, the RepeaterNet software
generates a new page with a severity of
1
, indicating that the Critical alarm remains.
•
If you then clear the
Critical
alarm, the RepeaterNet software generates a page with a
severity of
0
.
•
If the RepeaterNet software detects a
Minor
or
Event
alarm, it does not generate a page.
Table 41 Alarm Severity Code Numbers
Alarm Type
Severity Number
No Alarms
0
Critical Alarm
1
Major Alarm
2
Cr Major
3
Minor Alarm
4
Cr Minor
5
Major + Minor
6
Cr Major + Minor
7
Use the following procedure to set a pager.
1. Click on the
Pager Setting
tab of the
Modem Properties
screen.
2. Enter
the
Pager Number.
The
Pager Number
is the phone number to call. This phone number must include the
networking access number
(9), 1
, and the area code (if needed). Access the network dial
number, and wait five seconds before sending the page sequence.