— Chapter 1. Overview
PES1900Gi NR Operations Manual
6
Table 6 RepeaterNet Alarm, Monitoring, and Control
Access Options
Graphical User Interface
Functions
•
RS-232 (direct)
•
POTS (dial-up)
•
Wireless Modem
•
Windows 98 (Craft)
•
Windows NT (Master)
•
32-bit
•
Point and click
•
Pull-down menus
•
Summary Alarm
•
Interrupt Reporting
•
Definable Threshold
•
Remote Control: Gain, PA On/Off
Table 7 Repeater Supervision
SUPERVISION
ITEM
OUTPUT
ITEM
OUTPUT
ITEM
OUTPUT
Critical Alarm
Form C Relay
Remote Control
Relays (2)
Form C Relay
External Battery
Monitor
Analog DC Volts
Major Alarm
Form C Relay
Digital Outputs (2)
Opto-Isolated TTL
BUPS Monitor
6 Alarms
Minor Alarm
Form C Relay
Digital Inputs (2)
Opto-Isolated TTL
Visual Indicators
System Ready, Power
LED, Green
Major Alarm
LED, Red
Critical Alarm
LED, Red
Minor Alarm
LED, Red
Table 8 Alternate Power Supply Options
Type
Description
BUPS
6 – 14 hours of backup power without AC mains supply
Solar Electric Battery
PV (Photovoltaic) with controlled charging of station battery
Hybrid Solar and TEG
PV with Thermal Electric Generator powered from propane fuel
Hybrid Solar and MG
PV with Motor Generator powered from propane or diesel fuel
Table 9 Modem Options
Modem Options
•
Internal wireless modem
•
Internal 14400 bps modem card with an RJ-11 jack for a land-line connection through a Cellular Handset
NOTE: The repeater can also be ordered without a modem.
GSM Channel Assignments
In the following tables, lookup the range of GSM channels to be repeated, then find the
corresponding CDMA channel for the passband center. Assign that CDMA channel number to the
repeater using RepeaterNet Craft. CDMA channels can be set in 1-channel; 50 kHz increments.