background image

Relion 900

 

 

 

Power 

Effic

ient Intel-based HPC Server Designed for Next- generation D

atace

nters

 

 

 

 

T

ec

hni

c

al Guide 

Rev. 1.0

 

PENGUIN

 

COMPUTING

 

www.penguin

c

omputing.

c

om

 

| 1-888-PENGUIN (736-4846) | twitter:@PenguinHPC

 

Содержание Relion 900

Страница 1: ...Relion 900 Power E cient Intel based HPC Server Designed for Next generation Datacenters Technical Guide Rev 1 0 PENGUIN COMPUTING www penguincomputing com 1 888 PENGUIN 736 4846 twitter PenguinHPC...

Страница 2: ...R130 134 R130 234 Dual LGA2011 sockets R3 motherboard for Intel E5 2600 V3 series processors Service Guide Rev 1 0...

Страница 3: ...of this manual may be reproduced copied translated transmitted or published in any form or by any means without GIGABYTE s prior written permission Documentation Classifications Inordertoassistintheus...

Страница 4: ...NOT be covered in this generic service guide In suchcases please contact your regional offices or the responsible personnel channel to provide youwith further technical details 2 Please note WHEN ORDE...

Страница 5: ...el Memory Configuration 21 2 5 2 Installing a Memory 22 2 5 3 DIMM Population Table 22 2 6 Installing the PCI Expansion Card 23 2 7 Installing the Hard Disk Drive 24 2 8 Replacing the FAN Assemblly 25...

Страница 6: ...l 74 5 3 2 2 CPU C State Control 75 5 3 2 3 CPU T State Control 76 5 3 3 Common RefCode Configuration 77 5 3 4 QPI Configuration 78 5 3 5 Memory Configuration 80 5 3 5 1 Memory Topology 82 5 3 5 2 Mem...

Страница 7: ...RU Information 111 5 4 3 BMC network configuration 112 5 5 Security Menu 113 5 5 1 Secure Boot menu 114 5 5 1 1 Key Management 115 5 6 Boot Menu 117 5 7 Save Exit Menu 119 5 8 BIOS POST Codes 121 5 9...

Страница 8: ...stem Driver CD The box contents above are for reference only and the actual items shall depend on the product package you obtain The box contents are subject to change without notice The motherboard i...

Страница 9: ...not block or cover these openings Make sure youprovide adequate space around the system for ventilation when you set up your work area Never insertobjects of any kind into the ventilation openings To...

Страница 10: ...undesired opera tion Canadian Department of Communications Compliance Statement This digital apparatus does not exceed the Class A limits for radio noise emissions from digitalapparatus as set out in...

Страница 11: ...he waste collection centers for activation of the treatment collection recycling and disposal procedure The separate collection and recycling of your waste equipment at the time of disposal will help...

Страница 12: ...dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before...

Страница 13: ...82599ES 10GbE LAN controller with QSFP R130 234 Only 1 x Management LAN 10 100 1000Mpbs LAN port Expansion Slot R130 134 2 x PCI Express x8 slots Expansion Slot R130 234 2 x PCI Express x16 slot runn...

Страница 14: ...icated management LAN port 1 x COM port 1 x VGA port 1 x PS 2 connector Rear Panel I O R130 234 2 x USB 3 0 ports 1 x QSPF LAN port 1 x RJ 45 port 10 100 1000 Mbps dedicated management LAN port 1 x CO...

Страница 15: ...n operating Temperature 0oC to 50oC 10 80 operating Humidity at 30oC System Dimension 444Wx43 5Hx615D mm Electrical Power Supply Fixed 1U PSU 600W 100 240VAC at 80 plus gold level GIGABYTE reserves th...

Страница 16: ...15 Hardware Installation 1 3 System Block Diagram...

Страница 17: ...oth sides of the CPU and alignment keys on the CPU socket Apply an even and thin layer of thermal grease on the surface of the CPU Do not turn on the computer if the CPU cooler is not installed otherw...

Страница 18: ...is not turned on or connected to AC power Follow these instructions to remove the system cover 1 Loosen and remove the thumbscrew securing the front chassis cover 2 Press the the indentation located...

Страница 19: ...Installing the Fan Duct Follow these instructions to remove install the fan duct 1 Lift up to remove the fan duct 2 To install the fan duct align the fan duct with the guiding groove Push down the fan...

Страница 20: ...stem unit on a flat and stable surface Open the system according to the instructions WARNING Failure to properly turn off the server before you start installing components may cause serious damage Do...

Страница 21: ...nstall the heat sinks 1 Apply thermal compound evenly on the top of the CPU Remove the protective cover from the underside of the heat sink 2 Place the heat sink s on top of the CPU 3 Tighten the four...

Страница 22: ...econdary CPU Channel 3 DIMM_P0_C0 DIMM_P0_C1 For pimary CPU DIMM_P1_G0 DIMM_P1_G1 For secondary CPU Channel 4 DIMM_P0_D0 DIMM_P0_D1 For pimary CPU DIMM_P1_H0 DIMM_P1_H1 For secondary CPU Read the foll...

Страница 23: ...d Follow these instructions to install the Memory 1 Insert the DIMM memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DI...

Страница 24: ...equipment The PCI riser assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to PCI Expansion card 1 Lift t...

Страница 25: ...inserted incorrectly Make sure that the HDD is connected to the HDD connector on the backplane Follow these instructions to install the Hard disk drive 1 Press the release button 2 Pull the locking le...

Страница 26: ...Installation 2 8 Replacing the FAN Assemblly Follow these instructions to replace the fan assembly 1 Lift up the fan assembly from the chassis 2 Reverse the previous step to install the replacement f...

Страница 27: ...power supply 1 Disconnect the three power cables 2 Remove the four screws securing on the power supply 3 Lift the power supply out of the chassis in the direction of the arrow 4 Insert the replacemen...

Страница 28: ...ance 3 1 Front View No Decription 1 HDD bays 2 Front USB 3 0 ports 3 Front Panel LEDs and buttons 4 ID button and LED 5 Power button and LED Please Go to Chapter 3 3 Front Panel LED and Buttons for de...

Страница 29: ...100 1000 Server management LAN port 8 USB 3 0 ports 9 ID switch button 10 Low profile riser card bay No Decription 1 Power supply module cord socket 2 USB 3 0 ports 3 PS 2 Keyboard and Mouse connector...

Страница 30: ...System fan failure Power supply voltage issue System temperature voltage issue Blink N A Non critical condition may indicates the following Redundant power module failure Temperature and voltage issue...

Страница 31: ...N A No data transmission or receiving is occurring 5 NMI button Press the button server generates a NMI to the processor if the multiple bit ECC errors occur which effectively halt the server 6 Reset...

Страница 32: ...eiving is occurring 2 Port 1 Link Activity LED 1000 10G LAN Port Green On Link between system and network or no access Blink Data transmission or receiving is occurring Off No data transmission or rec...

Страница 33: ...32 3 5 Hard Disk Drive LEDs No Description Multi Color LEDs LED Active Green LED Active Amber 1 HDD Access Blink Off HDD Locate On Off HDD Failure Off On HDD connected and rebuilding data Blink Blink...

Страница 34: ...4 5 2 1 1 1 1 5 3 6 6 3 6 6 6 3 7 No Suggest Cable No Suggest Cable 1 System main power cable 2 Front panel USB 3 0 cable 3 SATA SAS HDD cable 4 Front switch cable Front LED cable 5 HDD back plane bo...

Страница 35: ...ents 4 1 MD60 SC1 MD60 SC2 Motherboard Components 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 21 22 23 24 25 26 19 20 29 30 27 28 36 35 37 33 34 31 32 40 41 42 43 44 45 47 49 50 51 56 57 58 59 60 61...

Страница 36: ...ary CPU 19 DIMM_P1_E0 Channel 1 slot 0 for secondary CPU 20 DIMM_P1_E1 Channel 1 slot 1 for secondary CPU 21 DIMM_P1_F0 Channel 2 slot 0 for secondary CPU 22 DIMM_P1_F1 Channel 2 slot 1 for secondary...

Страница 37: ...x8 slot 56 CASE_OPEN Case open intrusion alert header 57 ME_UPDATE ME update jumper 58 BIOS_PWD Clearing Supervisor Password jumper 59 BIOS_RCVR BIOS recovery jumper 60 ME_RCVR ME recovery jumper 61 S...

Страница 38: ...DOM5 SATA 5 DOM Jumper Pin No Definition 1 P5V 2 SATA5 Pin7 3 GND 3 CLR_CMOS Clearing CMOS Jumper 1 2 Close Normal operation Default setting 2 3 Close Clear CMOS data 4 5 6 7 8 9 1 2 3 CAUTION If a SA...

Страница 39: ...assword 6 BIOS_RCVR BIOS Recovery Jumper 1 2 Close Normal operation Default setting 2 3 Close BIOS recovery mode 7 ME_RCVR ME Recovery Jumper 1 2 Close Normal operation Default setting 2 3 Close ME re...

Страница 40: ...connector 10 11 FAN11 System fan connector 11 12 FAN12 System fan connector 12 13 J4 Define HDD Type jumper 1 2 Close SAS 2 3 Close SATA 14 J3 SATA LSI SCU Switch jumper Please refer to the following...

Страница 41: ...Hardware Installation 40 J2 J3 LSI SCU 2 3 Close 2 3 Close SATA 2 3 Close 1 2 Close 4 3 1 Back Plane BoadJ2 J3 Jumper Setting...

Страница 42: ...caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results...

Страница 43: ...ed setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you...

Страница 44: ...displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen H...

Страница 45: ...rsion Display BMC firmware version information SDR Version Display the SDR version information FRU Version Display the FRU version information Processor Information CPU Brand String Max CPU Speed CPU...

Страница 46: ...1 LAN2 LAN3 LAN4 MAC Address 3 4 for R130 234 Only Display LAN1 LAN2 LAN LAN4 MAC address information System Date Set the date following the weekday month day year format System Time Set the system ti...

Страница 47: ...Setup 46 5 2 Advanced Menu The Advanced menu display submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu sc...

Страница 48: ...47 BIOS Setup 5 2 1 Serial Port Console Redirection...

Страница 49: ...BIOS Setup 48...

Страница 50: ...Space Parity bit is always 0 Mark and Space Parity do not allow for error detection Options available None Even Odd Mark Space Default setting is None Stop Bits Stop bits indicate the end of a serial...

Страница 51: ...SCO ESCN VT400 Default setting is VT100 Redirection After BIOS POST Note This option allows user to enable console redirection after O S has loaded Options available Always Enable Boot Loader Default...

Страница 52: ...LAN devices and initialize device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Devices Common Settings PCI Latency Timer Value to be programmed into PCI Latency Tim...

Страница 53: ...em has SR IOV capable PCIe Devices this option enables or disables Single Root IO Virtualization Support Options available Enabled Disabled Default setting is Disabled PCI Express Settings Press Enter...

Страница 54: ...ble Enabled Disabled Default setting is Enabled Maximum Playload Set maximum playload for PCI Express Device or allow system BIOS to select the value Options available Auto 128 Bytes 256 Bytes 512 Byt...

Страница 55: ...n Link Status register Press keys to increase or decrease the desired values Value rang is from 10 to 10000 us Unpopulated Links When this item is set to Disable Link the system will operate power sav...

Страница 56: ...ure Options available Enabled DIsabled Default setting is Enabled Ipv6 PXE Support Note Enable Disable Ipv6 PXE feature Options available Enabled DIsabled Default setting is Enabled PXE boot wait time...

Страница 57: ...Do not allow disabling GA20 this option is useful when any RT code is executed above 1MB Options available Upon Request Always Default setting is Upon Request Option ROM Messages Option ROM Messages...

Страница 58: ...cution UEFI and Legacy Storage OpROM Options available Do not launch UEFI Legacy Default setting is Legacy Video Controls the execution UEFI and Legacy Video OpROM Options available Do not launch UEFI...

Страница 59: ...up 58 5 2 5 Post Report Configuration Post Report Configuration Error Message Report Post Error Message Enable Disable Info Error Message support Options available Enabled Disabled Default setting is...

Страница 60: ...ed Computing Configuration Security Device Support Select Enabled to activate TPM support feature Options available Enabled Disabled Default setting is Disabled Current Status Information Display curr...

Страница 61: ...tion Options available Enabled Disabled Default setting is Disabled USB Mass Storage Driver Support Note Enable Disable USB Mass Storage Driver Support Options available Enabled Disabled Default setti...

Страница 62: ...r On The default setting depends on the BMC setting Deep Sleep EuP Enable Disable Deep Sleep mode Options available Enabled Disabled Default setting is Disabled Fan Curve Mode Configure ystem fan curv...

Страница 63: ...BIOS Setup 62 5 9 SIO Configuration...

Страница 64: ...63 BIOS Setup...

Страница 65: ...ial Port 1 Configuration Use This Device When enabled allows you to configure the serial port 1 settings When set to Disabled displays no configuration for the serial port Options available Enabled Di...

Страница 66: ...O 2F8h IRQ 3 DMA IO 3F8h IRQ 3 4 5 7 9 10 11 12 DMA IO 2F8h IRQ 3 4 5 7 9 10 11 12 DMA IO 3E8h IRQ 3 4 5 7 9 10 11 12 DMA IO 2E8h IRQ 3 4 5 7 9 10 11 12 DMA Default setting is Use Automatic Settings P...

Страница 67: ...nfiguration iSCSI Initiator Name Add an Attempts Press Enter for configuration of advanced items Delete Attempts Press Enter for configuration of advanced items Change Attempt Order Press Enter for co...

Страница 68: ...enu Intel RC Setup menu displays submenu options for configuring the function of North Bridge and South Bridge Select a submenu item then press Enter to access the related submenu screen RC Revision D...

Страница 69: ...BIOS Setup 68 5 3 1 Processor Configuration...

Страница 70: ...ble Disable Intel Trusted Execution Technology support function Options available Enabled Disabled Default setting is Disabled VMX Vanderpool Technology Enable Disable Vanderpool Technology This will...

Страница 71: ...Options available Disabled 8 16 24 32 40 48 56 64 72 80 88 96 104 112 Default setting is 32 X2APIC Options available Enabled Disabled Default setting is Disabled AES NI Enable Disable AES NI Intel Adv...

Страница 72: ...71 BIOS Setup 5 3 1 1 Pre Socket Configuration...

Страница 73: ...ocket 0 1 Configuration Press Enter for configuration of advanced items Cores Enabled for CPU socket 0 1 Number of Cores to enable 0 means all cores 14 Cores is available Press the numeric keys to adj...

Страница 74: ...le Energy Efficient Custom Default setting is Energy Efficient Config TDP Options available Enabled Disabled Default setting is Disabled CPU P State Control Press Enter for configuration of advanced i...

Страница 75: ...Disabled Default setting is Enabled P state coordination In HW_ALL mode the processor hardware is responsible for coordinating the P state among logical processors dependencies The OS is responsible...

Страница 76: ...C6 non Retention state CPU C3 C6 Report Allows you to determine whether to let the CPU enter C3 C6 mode in system halt state When enabled the CPU core frequency and voltage will be reduced during sys...

Страница 77: ...BIOS Setup 76 5 3 2 3 CPU T State Control ACPI T States Enable Disable CPU throttling by OS Thorttling reduces power comsumption Options available Enabled Disabled Default setting is Enabled...

Страница 78: ...mmon RefCode Configuration Common RefCode Configuration Isoc Mode Options available Auto Enabled Disabled Default setting is Auto Numa Non Uniform Memory Access Options available Enabled Disabled Defa...

Страница 79: ...BIOS Setup 78 5 3 4 QPI Configuration...

Страница 80: ...for configuration of advanced items QPI Status Press Enter to view QPI status Link Speed Mode Options available Slow Fast Default setting is Fast Link Frequency Select Options available 6 4GB s 8 0GB...

Страница 81: ...uency Options available Auto 1333 1400 1600 1800 1867 2000 2133 Default setting is Auto ECC Support Options available Auto Disabled Enabled Default setting is Auto Rank Margin Tool Options available A...

Страница 82: ...81 BIOS Setup Memory Map Press Enter for configuration of advanced items Memory RAS Configuration Press Enter for configuration of advanced items...

Страница 83: ...BIOS Setup 82 5 3 5 1 Memory Topology...

Страница 84: ...hrottling Mode Configure Thermal Throttling Mode Select OLTT or CLTT mode Options available Disabled CLTT Mode Default setting is CLTT Mode MEMHOT Throttling Mode Options available Disabled Output onl...

Страница 85: ...al memory below 4GB Options available Disabled Enabled Default setting is Disabled Channel Interleaving Options available Auto 1 way Interleave 2 way Interleave 3 way Interleave 4 way Interleave Defau...

Страница 86: ...enabled Sparing will be selected Options available Disable Mirror Lockstep Mode Default setting is Disabled Lockstep x4 DIMMs Options available Auto Disabled Enabled Default setting is Auto Memory Ran...

Страница 87: ...res Set this option to allow DFX Lock Bits to remain clear Options available Enabled Disabled Default setting is Disabled IOAT Configuration Press Enter for configuration of advanced items Intel VT fo...

Страница 88: ...le IOAT Control to enable disable IOAT Intel I O Acceleration Technology device Options available Enabled Disabled Default setting is Disabled No Snoop Enable Disable PCI Express Device No Snoop optio...

Страница 89: ...O VT d Enable Disable Intel VT for Directed I O VT d support function Options available Enabled Disabled Default setting is Enabled Interrupt Remapping Enable Disable interrupt remapping support funct...

Страница 90: ...vices Press Enter for configuration of advanced items PCH sSATA Configuration Press Enter for configuration of advanced items PCH SATA Configuration Press Enter for configuration of advanced items USB...

Страница 91: ...BIOS Setup 90 5 3 7 1 PCH Devices PCH CRID Enable Disable Intel Compatible Revision ID Options available Enabled Disabled Default setting is Disabled...

Страница 92: ...91 BIOS Setup 5 3 7 2 PCH sSATA Configuration...

Страница 93: ...RAID setup utility at boot time ACHI Mode When set to AHCI the SATA controller enables its AHCI functionality Then the RAID function is disabled and cannot be access the RAID setup utility at boot ti...

Страница 94: ...vailable Enabled Disabled Default setting is Enabled Hot Plug for Port 0 1 2 3 Note Enable Disable HDD Hot Plug function Options available Enabled Disabled Default setting is Disabled Configured as eS...

Страница 95: ...p 94 5 3 7 2 1 SATA Mode Options SATA LED locate When this option is enabled LED SGPIO hardware is attached Options available Enabled Disabled Default setting is Enabled When SATA Type is set to IDE A...

Страница 96: ...ns available Enabled Disabled Default setting is Enabled RAID Option ROM UI banner Options available Enabled Disabled Default setting is Enabled IRRT Only on ESATA Options available Enabled Disabled D...

Страница 97: ...BIOS Setup 96 5 3 7 3 PCH SATA Configuration...

Страница 98: ...lity at boot time ACHI Mode When set to AHCI the SATA controller enables its AHCI functionality Then the RAID function is disabled and cannot be access the RAID setup utility at boot time Options avai...

Страница 99: ...etect HDD type Port 0 1 2 3 4 5 Enable Disable Port 0 1 2 3 device Options available Enabled Disabled Default setting is Enabled Hot Plug for Port 0 1 2 3 4 5 Note Enable Disable HDD Hot Plug function...

Страница 100: ...Setup 5 3 7 3 1 SATA Mode Options SATA LED locate When this option is enabled LED SGPIO hardware is attached Options available Enabled Disabled Default setting is Enabled When SATA Type is set to IDE...

Страница 101: ...ecovery Technology support function Options available Enabled Disabled Default setting is Enabled RAID Option ROM UI banner Options available Enabled Disabled Default setting is Enabled Smart Response...

Страница 102: ...ition work on USB host conteoller and root ports for faster enumeration Options available Enabled Disabled Default setting is Disabled xHCI Mode Enable Disable xHCI USB 3 0 support function Options av...

Страница 103: ...BIOS Setup 102 5 3 8 Miscellaneous Configuration Miscellaneous Configuration Active Video Select active Video type Options available Onboard Device Offboard Device Default setting is Offboard Device...

Страница 104: ...are Version Display Recovery Firmware Version information ME Firmware Features Display ME Firmware features information ME Firmware Status 1 2 Display ME Firmware status information Current State for...

Страница 105: ...etting is Enabled S W Error Injection Support Enable Disable software injection error logging function Options available Enabled Disabled Default setting is Disabled Whea Settings Press Enter for conf...

Страница 106: ...105 BIOS Setup 5 3 10 1 Whea Setting WHEA Support Windows Hardware Error Architecture Enable Disable WHEA Support Options available Enabled Disabled Default setting is Enabled...

Страница 107: ...rror Enabling Memory Error Enabling Un Correctable Errors disable Memory Options available Enabled Disabled Default setting is Disabled Memory corrected Errors enabling Options available Enabled Disab...

Страница 108: ...ing is Enabled Fatal Error Enable Options available Enabled Disabled Default setting is Enabled Enable SERR propagation When this item is set to enabled PCI bus system error SERR is generated and is r...

Страница 109: ...n Default setting is Do Nothing Please note that this item is configurable when FRB 2 Timer is set to Enabled OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disa...

Страница 110: ...OS Setup System Event Log Press Enter for configuration of advanced items View FRU Information Press Enter to view the advanced items BMC network configuration Press Enter for configuration of advance...

Страница 111: ...options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase...

Страница 112: ...BIOS Setup 5 4 2 View FRU Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable R130 134 R13...

Страница 113: ...ing option willnot modify any BMC network parameters during BIOS phase Options available Unspecified Static DynamicBmcDhcp Default setting is Unspecified Static Station IP Address Display IP Address i...

Страница 114: ...disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Administrator Password Press Enter to configure...

Страница 115: ...running during the booting process to be pre signed with valid digital certificates This way the system knows all the files being loaded before Windows 8 loads and gets to the login screen have not be...

Страница 116: ...to install all factory default keys Save All Secure Boot Variables Press Enter to save all Secure Boot Variables Platform Key PK Display the status of Platform Key Delete the PK Press Enter to delete...

Страница 117: ...nter to delete the db from your system Set new DB Press Enter to configure a new db Append aVar to DB Press Enter to load additional db from a storage devices Forbidden Signature Database DBX Display...

Страница 118: ...e waiting Press the numberic keys to input the desired value Bootup NumLock State Enable or Disable Bootup NumLock function Options available On Off Default setting is On Quiet Boot Enables or disable...

Страница 119: ...BIOS Setup 118 Network Device BBS Priorities Press Enter to configure the boot priority Hard Drive BBS Priorities Press Enter to configure the boot priority...

Страница 120: ...s available Yes No Save Options Save Changes Saves changes made in the BIOS setup Options available Yes No Discard Changes Discards changes made and close the BIOS setup Options available Yes No Resto...

Страница 121: ...BIOS Setup 120 Boot Override Press Enter to configure the device as the boot up drive UEFI Built in in EFI Shell Press Enter on this item to Launch EFI Shell from filesystem device...

Страница 122: ...30 PEI_MEMORY_INSTALLED 0x31 PEI_CPU_INIT 0x32 PEI_CPU_CACHE_INIT 0x33 PEI_CPU_BSP_SELECT 0x34 PEI_CPU_AP_INIT 0x35 PEI_CPU_SMM_INIT 0x36 PEI_MEM_NB_INIT 0x37 reserved for NB 0x38 0x3A PEI_MEM_SB_INIT...

Страница 123: ...VERS 0x91 DXE_PCI_BUS_BEGIN 0x92 DXE_PCI_BUS_HPC_INIT 0x93 DXE_PCI_BUS_ENUM 0x94 DXE_PCI_BUS_REQUEST_RESOURCES 0x95 DXE_PCI_BUS_ASSIGN_RESOURCES 0x96 DXE_CON_OUT_CONNECT 0x97 DXE_CON_IN_CONNECT 0x98 D...

Страница 124: ...0x50 PEI_MEMORY_INVALID_SPEED 0x50 PEI_MEMORY_SPD_FAIL 0x51 PEI_MEMORY_INVALID_SIZE 0x52 PEI_MEMORY_MISMATCH 0x52 PEI_MEMORY_NOT_DETECTED 0x53 PEI_MEMORY_NONE_USEFUL 0x53 PEI_MEMORY_ERROR 0x54 PEI_MEM...

Страница 125: ...STATUS_CODE DXE_CPU_ERROR 0xD0 DXE_NB_ERROR 0xD1 DXE_SB_ERROR 0xD2 DXE_ARCH_PROTOCOL_NOT_AVAILABLE 0xD3 DXE_PCI_BUS_OUT_OF_RESOURCES 0xD4 DXE_LEGACY_OPROM_NO_SPACE 0xD5 DXE_NO_CON_OUT 0xD6 DXE_NO_CON_...

Страница 126: ...Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Con...

Страница 127: ...can be used to restore the BIOS to a working state To restore your BIOS please follow the instructions listed below Recovery Instruction 1 Change xxx ROM to amiboot rom 2 Copy amiboot rom and AFUDOS...

Отзывы: