Pelsis CURTIS DYNA-FOG HURRICANE ES HESEU Скачать руководство пользователя страница 1

230V electrostatic fogger

USER MANUAL

Содержание CURTIS DYNA-FOG HURRICANE ES HESEU

Страница 1: ...230V electrostatic fogger USER MANUAL ...

Страница 2: ...e product THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE EXCLUDED AND CURTIS DYNA FOG SHALL HAVE NO LIABILITY FOR ANY CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES EVEN IF CURTIS DYNA FOG WAS APPRISED OF THE POSSIBILITY THEREOF In no event shall CURTIS DYNA FOG s liability hereunder exceed the amount of the purchase price paid for the product Any warranty claim must...

Страница 3: ... FIRE EXPLOSION OR ELECTRICAL SHOCK HAZARD MODEL HESUK 10001 SERIAL UNITED STATES PATENT 4 177 949 CANADIAN PATENT 1 101 381 230V 50Hz 4 15A POWER 930W DISCONNECT THE POWER SUPPLY BEFORE SERVICING Pelsis Ltd HG5 8PJ UK Pelsis Belgium NV Bornem 2880 WARNING Read and understand operator s manual and all other safety instructions before using this equipment WARNING Always have the machine serviced by...

Страница 4: ...e of this appliance This appliance is designed to operate from three wire power systems where one of the wires is a safety ground Use a GFCI Ground Fault Circuit Interrupter power outlet whenever possible Do not disconnect the safety ground or use extension leads or cheater plugs to connect this machine to a two wire system This machine must be used with a 3 prong grounded extension lead plugged i...

Страница 5: ...t unplug machine with wet hands Replace damaged or worn electric lead immediately Turn the flow valve CLOCKWISE to the OFF position after each fogging application while the motor is still operating to allow clearing of the lines Always comply with any requirements for protective clothing goggles facial masks or respiratory equipment required by the formulation label Ensure that formulation is appl...

Страница 6: ...output and particle size are dependent upon the viscosity of the liquid being dispensed See table 2 for particle size vs valve setting flow rate Hurricane ES HESUK Hurricane ES HESEU Motorized Blower High efficiency Motor Blower Brush Life Approximately 1000 hours Electrostatic Power Supply 230V Current Draw 230V 3 40 A 50Hz Nozzle Type Professional grade electrostatic 3 nozzle air assist vortical...

Страница 7: ...it clockwise There are three flow indicator marks on the side of the tank that designate position 1 position 2 and position 3 All flow rate information is based on using water with a temperature of 21 C Increasing the viscosity will decrease flow rate and can increase droplet size Refer to the table below for approximate flow rates and droplet sizes at the various valve settings Droplet sizes are ...

Страница 8: ...ver smaller size droplets in the 10 20 micron range can be effective when targeting microorganisms suspended in the air Formulation Tube Metering Valve Approximate flow rates for the valve position settings are as follows Position Flow rate Droplet Size Microns 1 60 ml min 10 20 2 90 ml min 20 30 3 120ml min 30 50 Flow rates shown are approximate and will vary depending on liquid viscosity and tem...

Страница 9: ...the electrical lead for evidence of damage and replace any damaged lead immediately 3 Clean the Air Intake Filter after every application If the filter gets saturated wet and dripping while the machine is working stop the machine and clean the filter 7 0 Noise Level The Hurricane ES noise levels do not require hearing protection however we would still recommend it especially when using it for prol...

Страница 10: ......

Отзывы: