Installation shall conform to CAN/CSA B365 Installation Code for Solid-Fuel-Burning Appliances and Equipment in Canada 

and NFPA 211 Chimney, Fireplaces, Vents and Solid Fuel Burning Appliances in the USA. 

 

Contact local building or fire officials to obtain a permit and information on any installation  

requirements and installation inspection requirements in your area. 

 

To obtain a French translation of this manual, please visit www.pelprostoves.com 

Pour obtenir une traduction française de ce manuel, s'il vous plaît visitez www.pelprostoves.com 

 

7081-146E 

READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR HEATER, FAILURE TO FOLLOW 

INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH 

Owner’s Manual 

SAVE THESE INSTRUCTIONS 

Freestanding   

 

     HHPP2  

 

             PP300   

 

Multi-Fuel Step Top 

Содержание Freestanding

Страница 1: ...A Contact local building or fire officials to obtain a permit and information on any installation requirements and installation inspection requirements in your area To obtain a French translation of this manual please visit www pelprostoves com Pour obtenir une traduction française de ce manuel s il vous plaît visitez www pelprostoves com 7081 146E READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND US...

Страница 2: ...d characteristics of the fuel you burn Corn or Wood Pellets can vary greatly from company to company from load to load and occasionally from bag to bag Be extra diligent in your cleaning program Remember that a very high percentage of operational dilemmas with a pellet stove are usually traced back to improper installation poor quality fuel and or lack of timely cleaning With just a minimum of dai...

Страница 3: ...XHAUST SYSTEMS SERVICE PARTS ACCESSORIES 38 TYPE 10 LIMITED WARRANTY 39 SAFETY PRECAUTIONS DETERMING SIZE DISTANCE 11 TERMINATION 12 PLANNING OUTSIDE AIR 13 APPLIANCE PLACEMENT 14 FLOOR PROTECTION CLEARANCES TO COMBUSTIBLES INSTALLATION TOOLS OF THE TRADE 16 STEP BY STEP DIRECT VENT INSTALLATION 17 MOBIILE HOME 18 INSTALLATIONS OPTIONS 19 OPERATION BEFORE LIGHTING YOUR FIRST FIRE 21 USING THE ACUT...

Страница 4: ...dard 115 V 60 Hz 3 prong grounded electrical outlet in accordance with local building codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 A grounded surge protection unit is recommended Do not use an adapter plug or sever the grounding prong on the electrical plug Do not route the electrical cord underneath in front of or over the heater Do not unplug the stove if...

Страница 5: ...ming any maintenance Pushing OFF Touch Pad does not disconnect all power to the heater The exhaust system should be checked twice a year minimum for any build up of soot or creosote Do not touch the hot surfaces of the heater CAUTION Odors and vapors released during initial operation Curing of high temperature paint Open windows for air circulation Odors may be irritating to sensitive individuals ...

Страница 6: ...s out the exhaust of your stove along with gases into the atmosphere Your stove s heat output can be adjusted from setting 1 4 through the FEED RATE touch pad to vary your heat output from Low to High The room air fan can be manually adjusted through the FAN SPEED to run faster or slower to corre spond to the amount of heat being produced The room air fan is also on a limit switch controlled to ru...

Страница 7: ...igh temperature limit switch installed If the temperature at the back of the firebox reaches approximately 250 F the switch will shut off the electricity going to the Vacuum Switch and to the Auger Motor The auger will automatically stop and the appliance will shut down when the exhaust temperature cools 120 F If this happens call your dealer or Hearth Home Technologies Customer Service 1 877 427 ...

Страница 8: ... you may wish to purchase a gas powered generator solar or battery back up system Ensure that it is a Positive sign wave and a minimum 1000 watts continual as well as surge protection EPA COMPLIANCE This heater is exempt from EPA Phase II requirements but has been tested for emissions using EPA test methods by Warnock Hersey US Pellet appliances that are designed with the combustion air supply ex ...

Страница 9: ...oof of purchase to this manual and keep on hand for warranty COMPLETE THIS CHECK LIST WHILE INSTALLING YOUR MULT FUEL APPLIANCE _____ Carefully read the ENTIRE installation section first Twice is better _____ Read the Installing Freestanding Insert or Built In sections _____ Determine the location and measurement needed your chosen location _____ Be sure to pre fit all items before you install fas...

Страница 10: ...a vent VENT SAFETY PRECAUTIONS A Clean Out Tee 4 must be installed at the bottom of all vertical runs These Tee s are to assist in periodically cleaning the vent Single or Double clean out tees may be used The exhaust system must be installed so the entire system can be cleaned without disassembly Termination must exhaust above the fresh air inlet elevation and parallel or above the exhaust output...

Страница 11: ... Altitude above sea level NOTE In some cases it may be necessary to contact Hearth Home Technologies Customer Service personal to determine acceptable venting configurations and altitude adjustments 1 877 427 3316 The diagram to the right will help to give you a visual reference 0 1 2 3 4 5 6 7 8 9 10 10 20 30 Altitude in Thousands of Feet Equiva lent Pipe Length in Fe et 3 or 4 Inch Diameter Pipe...

Страница 12: ...1 clearance above any door or window that opens C Minimum 3 clearance from any adjacent building D Minimum 7 clearance above any grade when adjacent to public walkways E Minimum 2 clearance above any grass plants or other combustible material Minimum 1 clearance above grade F Minimum 3 clearance above any forced air intake of any other appliance within 6 G Minimum 2 clearance below eves or overhan...

Страница 13: ... foot away from the exhaust system termination When outside air is taken from an existing chimney the exhaust system must not terminate in the same chimney The outside air pipe on your stove is 2 OD The outside air connecting pipe must be at least 2 ID The outside air connecting pipe must be as short and free of elbows as possible and must fit over A not inside the outside air pipe on your stove F...

Страница 14: ...e section Alcove Installation 2 From Back Of Stove to Combustibles 3 From PL Vent to Combustibles 10 From Front Side of Stove to Combustibles 2 From Back Corner of Stove to Combustibles 6 Non Combustible Surface In Front Of Heater 16 From Top Of Stove to Combustibles 36 to drapes doors anything that can swing 6 1 10 6 2 10 12 THROUGH THE WALL 6 3 10 INTERIOR VERTICAL 6 6 6 6 10 Stove and floor pro...

Страница 15: ...ng on the brand of PL vent used Before placing the stove connect the Tee and measure off the 3 clearance ALCOVE INSTALLATION Minimum clearances to combustibles Figure 14 15 2 inch from back of appliance 10 inches from the sides 16 inches from the top 30 inches deep Figure 14 Figure 15 2 12 6 THROUGH THE WALL 45 CORNER 3 6 10 INTERIOR VERTICAL 45 CORNER 10 1 0 6 6 6 6 6 1 10 6 2 12 ALCOVE THROUGH T...

Страница 16: ...t and wood drill bits Flashlight Wire stripper and wire cutter Hammer Bubble Level Utility knife Adjustable pliers 6 to 8 inches Small hand broom and dustpan Furniture and Floor Protection Supplies Caulking tube of RTV Hi Heat Silicone Caulking tube of Clear Silicone Hi Heat Aluminum Foil Tape 2 long Wood screws 10 Assortment of sheet and wood screws Stove Bright Hi Heat Stove Paint Before startin...

Страница 17: ...he 4 x 7 16 nuts supplied and secure tightly 6 Place a bead of RTV silicone around the end collar of the Quick Connect of your stove s exhaust C Firmly push the PL vent pipe adaptor J into the bead of RTV silicone Note If 4 PL vent is required use an 3 to 4 Pipe Adaptor Increaser J on the stove exhaust pipe 7 Connect the length of PL vent E that is in the thimble F onto the pipe adaptor D Fasten t...

Страница 18: ...ge copper wire B figure 25 or equivalent The stove must have a permanent outside air source with a inch screen over the inlet Figure 26 B C D For transportation all chimney vent above the mobile home must be removed Chimney PL Vent must be 3 or 4 PL Vent and must extend a minimum or 36 above the roofline of the mobile home and must be installed using a UL ULC listed ceiling fire stop J figure 26 a...

Страница 19: ...ide natural draft to help evacuate smoke from the appliance in case of power failure Follow the same basic steps in locating your appliance attaching the exhaust system and outside air intake to your stove as the previous examples 1 2 3 4 5 6 7 8 Main Floor Vertical 1 Pipe Adapter Clean Out Tee Cap 3 x 60 15 Pipe Length Tee Support Bracket Ceiling Support Firestop Spacer Roof Flashing Storm Collar...

Страница 20: ...apping Screws x 27 7 6 24 8 PL Clean Out Tee Cap PL Length of Pipe PL 90D Elbow PL Wall Thimble 10 11 12 1 2 3 4 5 Cleanout Door 9 10 11 Main Floor Class A Tie In 1 Pipe Adapter Clean Out Tee Cap 3 x 60 15 Pipe Length Tee Support Bracket Ceiling Support Firestop Spacer Roof Flashing Storm Collar Vertical Rain Cap 2 3 4 5 6 7 8 Tube of RTV Silicone Roll of Foil Tape 3 8 Stainless Self Tapping Screw...

Страница 21: ...in all the Way then pull outward approximately 1 2 This may not be the final setting We will cover FINE TUNNING YOUR STOVE later in this manual OPENING AND CLOSING THE MAIN DOOR Open the stove door by rotating the handle COUNTER CLOCKWISE toward the TOP of the stove until the handle is about the 3 o clock position Swing door open to the left Close the stove door by keeping the handle at the 3 o cl...

Страница 22: ...has heated to normal operating temperatures your stove will continue to run If the fire does not light and or burn properly the electricity to your stove s components will be shut off at the end of 15 minutes The FAN SPEED controls the speed of the room air fan This fan blows room air through the heat exchange tubes and back into the room When the FEED RATE is set to a higher position the FAN SPEE...

Страница 23: ... setting All 4 Lights Feed Rates 1 2 All 4 Lights All 4 Lights Feed Rates 3 4 Feed Rates 1 4 Only be concerned with the lights All others do not effect the mode selection process FEED RATE NOTE The Starting Point of the cycle depends on what mode the control was in Thermostat On Off Mode Thermostat Low High Mode Manual You are in control OPERATING IN MANUAL MODE TO START Step 1 Press the START tou...

Страница 24: ... the low heat 1 cycle When the temperature in the room drops to the level set at the thermostat the stove will again cycle to the HIGH 2 3 or 4 preselected set ting For optimum heat transfer the FAN setting should be set at LOW or MEDIUM The appliance will run the FAN at HIGH speed when needed automatically TO SHUT DOWN To turn off the appliance press the OFF touch pad TO START con t After Pushing...

Страница 25: ...position the FAN SPEED should be set higher and visa versa HI MED LOW FAN SPEED OFF FAN SPEED AUGER CYCLE FINE TUNE ADJUSTMENTS 1 4 FAN Increase Decrease Operation Instructions Understanding the Control OPERATING IN THERMOSTAT ON OFF Flashing 1 2 This also requires purchasing the optional Wall Thermostat Add on Kit This mode of operation is best suited for those Take Off The Chill nights of spring...

Страница 26: ...o solid on LOW setting The AUGER CYCLE LED will go solid for 3 sec onds indicating signal being sent to auger motor 2 Place a small amount of a solid fuel fire starter such as those made from sawdust and wax or use wood shavings in the bottom of the burn grate Add a small handful of pellets to the starter material Add a small amount of fire starter over the pellets CAUTION DO NOT USE ANY FLAMMABLE...

Страница 27: ... run on HIGH for 10 minutes before you begin to make adjustments AUGER CYCLE indicator should be lit ON for 3 seconds and OFF for 3 5 seconds Adjust the AIR INLET DAMPER This will have to be set as the factory can not send the units out with the damper pre set This is done to ac commodate a wide range of installations elevations and fuel type and quality Slide the damper closed pushed in all the w...

Страница 28: ...l heat output and visa versa Pellet feed rate at the same fuel settings may vary greatly from brand to brand and may vary somewhat from batch to batch within the same brand FINES FINES in pellets are pieces of sawdust that were not properly formed or are the results of pellets breaking down from handling transporting and or storage Fines adversely affect the operations and heat production of a pel...

Страница 29: ...g season unless properly stored If you do decide to carry it over make sure to check the corn for proper moisture content FACTORS EFFECTING FEED RATES Generally the smaller and cleaner free from fine dust and debris the corn is the faster it will feed at a given setting and visa versa The extremes in corn size moisture and quality can cause several hours difference in burning time for a hopper ful...

Страница 30: ...s well BURN POT A COLD STOVE ONLY Remove the burn grate Clean out the burn pot area of all debris CAUTION When replacing the grate make sure it fits properly in the burn pot DISPOSALE OF ASHES COLD STOVE ONLY Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground well away from all combustible m...

Страница 31: ...Inspect the main door gasket periodically The main door may be removed to have frayed broken or compacted gaskets replaced EXHAUST VENTING Soot and Fly Ash Formation and Need for Removal The by products of com bustion contain small particles of fly ash Fly ash will collect in the exhaust venting system and restrict the flow of flue gases Incomplete combustion such as during startup shutdown or inc...

Страница 32: ...lution along with a rag Oven cleaner and window cleaners will leave a film on the glass that will attract smoke and creosote like a magnet Should a build up of creosote or carbon accumulate you may wish to use 000 steel wool and water to clean glass Ceramic is very hard and will not scratch from the steel wool GLASS REPLACEMENT In the event you need replacement only Hi Temp Neo Ceram of the correc...

Страница 33: ...ill be a charge for this service PROBLEM CAUSE SOLUTION Stove Will Not Start 1 No electrical power Ensure the stove is plugged in to a 120VAC electrical outlet and a Surge Protection unit Check outlet for electrical power and proper voltage Check spade connections from the stove power cord to the main wiring harness Ensure door is closed and securely latched Ensure ash pan is tightly secured 2 Con...

Страница 34: ...pect burn grate Remove all ash and clinkers Ensure air holes are free of debris or build up 3 Igniter is not glowing Remove burn grate close door and re start the appliance If the igniter does not glow red inside the tube it is defective Remove back panel and confirm wire connections and condition of wires If igniter is defective the stove can be started manually See manual lighting instructions 4...

Страница 35: ... elements Smoke or smoke smell spillage 1 Exhaust System Hi Heat RTV silicone all joints even manufactured Ensure venting is gas tight Inspect exhaust fan and gasket area ensure a tight fit Proper maintenance and cleaning 2 Over Feeding Fuel over filling burn grate Check air inlet damper for proper setting Adjust feed rate to lower level The stove keeps going out 1 Fresh unburned fuel or powder li...

Страница 36: ...Tron enters a 5 minute Safety Delay mode F125 FAN LIMIT SWITCH Your pellet appliance has a convection fan control limit switch The room air fan s F125 temperature limit snap switch automatically sets the fan on high when your stove is producing heat fast than the fan is carrying it into the room This may occur when the heat control lever is set at 3 or 4 and the FAN SPEED is set to a very low or o...

Страница 37: ...www pelprostoves com 7081 146E 37 Trouble Shooting F125 F125 Molex 9 Pin Connector Vacuum Switch Hopper Safety Switch F125 ...

Страница 38: ...asket Combustion Fan 1 8 KS 5020 1052 Convection Fan w gasket KS 5060 1180 Gasket Convection Fan 1 8 KS 5040 1101 Control Board AcuTron 4 KS 5050 1130 Firebrick KS 5060 1160 Gasket Door 5 8 Dia X 60 long KS 5060 1150 Gasket Window Tape KS 5060 1200 Gasket Ash Pan KS 5060 1190 Gasket Exhaust KS 5070 1210 Glass Flat Stove Neo Ceramic KS 5030 1061 Igniter KS 5050 1140 1 piece Stainless Steel Brick Ho...

Страница 39: ...of the stove NEITHER THE MANUFACTURER NOR THE SUPPLIERS TO THE PURCHASER ACCEPTS RESPON SIBILITY LEGAL OR OTHERWISE FOR THE INCIDENTAL OR CONSEQUENTIAL DAMAGE TO THE PROPERTY OR PERSONS RESULTING FROM THE USE OF THIS PRODUCT ANY WARRANTY IM PLIED BY LAW INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANT ABILITY OR FITNESS SHALL BE LIMITED TO ONE 1 YEAR FROM THE DATE OF ORIGINAL PUR CHASE ...

Страница 40: ...40 7081 146E www pelprostoves com ...