Pellas X CAN I/O MC-1 Скачать руководство пользователя страница 1

EXPANSION MODULE

CAN I/O MC-1

Содержание CAN I/O MC-1

Страница 1: ...EXPANSION MODULE CAN I O MC 1...

Страница 2: ...page 2 PL20110609...

Страница 3: ...tput power 12V 11 2 5 Modules addressing 11 3 Circuits diagrams 13 3 1 System 1 13 3 2 System 2 15 3 3 System 3 17 3 4 System 4 19 3 5 System 5 21 4 Description of input and output modules 23 4 1 Modu...

Страница 4: ...odules communicate with the main controller using well known for reliability widely used in automotive CAN bus Modular design allows for adjustment automatics to the heating system requirements By usi...

Страница 5: ...wed by a child Do not make any mechanical or electrical changes to the unit Such changes may cause the unit to malfunction and fail to meet the relevant standards leading to an adverse impact on the p...

Страница 6: ...to the unit Do not clean the casing of the unit with petrol solvents or any other chemicals that may damage the casing of the unit Using a soft cloth is recommended 1 4 Disposal of old equipment This...

Страница 7: ...by a person possessing adequate permissions in this area WARNING The device must be connected to a separate electrical circuit equipped with an appropriately sized circuit breaker and residual curren...

Страница 8: ...2 Connecting to the system 2 3 Assembly The unit is suitable for mounting on standard 35mm DIN rail All dimensions are in millimetres page 8 PL20110609...

Страница 9: ...2 Connecting to the system 2 4 Connecting Description IN inputs OUT outputs CAN CAN bus 12V power output 12V 230V power module Pellas X Pellet burners www pellas pl page 9 PL20110609...

Страница 10: ...the power cord Description L phase vein brown N neutral vein blue PE protective vein yellow green 2 4 2 CAN For connections to CAN bus should be only used cable LiYCY 2x0 25 Only this type of cable gi...

Страница 11: ...o broadcast the address of the module is used DIP switch The whole system can be only one module for each address Total value of switches with numbers 1 2 3 in the ON position sets the unit number eg...

Страница 12: ...odule 6 ON ON ON Module 7 DIP switch with number 4 T is used to set the terminator The whole system must be 2 terminators 1 As standard includes a main unit that is controller PELLAS line 2 Must be ma...

Страница 13: ...dresses 0 4 Each expansion module controls three heating circuits with a circulating pump and mixer In addition the module number 0 reads outdoor temperature from the sensor mounted outside the buildi...

Страница 14: ...3 Circuits diagrams page 14 PL20110609...

Страница 15: ...ment is controlled by three heating circuits with a circulating pump and mixer Module 0 of the outside mounted sensor reads the outdoor temperature Collectors are supervised by the module I O address...

Страница 16: ...3 Circuits diagrams page 16 PL20110609...

Страница 17: ...g pump and mixer Module 0 of the outside mounted sensor reads the outdoor temperature Module No 5 controls charging pump heat buffer Also operates a boiler with a pump mixing with mixer whose task is...

Страница 18: ...3 Circuits diagrams page 18 PL20110609...

Страница 19: ...dule 0 of the outside mounted sensor reads the outdoor temperature Module No 5 manages the charging pump heat buffer Also controls the boiler pump mixing with a mixer whose task is to maintain a minim...

Страница 20: ...3 Circuits diagrams page 20 PL20110609...

Страница 21: ...d mixer Module 0 of the outside mounted sensor reads the outdoor temperature Module No 5 manages the charging pump heat buffer Also controls the boiler pump mixing with a mixer whose task is to mainta...

Страница 22: ...3 Circuits diagrams page 22 PL20110609...

Страница 23: ...sing mixer circuit CH 3 Mclo3 31 GND 5 DO5 opening mixer circuit CH 4 Mope4 32 AIN4 room temperature sensor circuit 3 Troom3 6 DO6 closing mixer circuit CH 4 Mclo4 33 AIN5 CH temperature sensor circui...

Страница 24: ...ensor circuit 6 Tch6 4 DO4 closing mixer circuit CH 6 Mclo6 31 GND 5 DO5 opening mixer circuit CH 7 Mope7 32 AIN4 room temperature sensor circuit 6 Troom6 6 DO6 closing mixer circuit CH 7 Mclo7 33 AIN...

Страница 25: ...DO4 closing mixer circuit CH 9 Mclo9 31 GND 5 DO5 opening mixer circuit CH 10 Mope10 32 AIN4 room temperature sensor circuit 9 Troom9 6 DO6 closing mixer circuit CH 10 Mclo10 33 AIN5 CH temperature se...

Страница 26: ...nsor circuit 12 Tch12 4 DO4 closing mixer circuit CH 12 Mclo12 31 GND 5 DO5 opening mixer circuit CH 13 Mope13 32 AIN4 room temperature sensor circuit 12 Troom12 6 DO6 closing mixer circuit CH 13 Mclo...

Страница 27: ...15 4 DO4 closing mixer circuit CH 15 Mclo15 31 GND 5 DO5 opening mixer circuit CH 16 Mope16 32 AIN4 room temperature sensor circuit 15 Troom15 6 DO6 closing mixer circuit CH 16 Mclo16 33 AIN5 CH tempe...

Страница 28: ...ture 29 AIN2 upper temperature buffer sensor Tbufu 3 DO3 not connected 30 AIN3 lower temperature buffer sensor Tbufd 4 DO4 not connected 31 GND 5 DO5 solar mixer L 32 AIN4 boiler return temperature se...

Страница 29: ...Manufactured by PHU Isol s c ul Szybownik w 39 10 64 920 Pi a POLAND Tel 48 67 214 71 32 fax 48 67 252 27 69 biuro pellas pl www pellas pl Pellas X Pellet burners www pellas pl page 29 PL20110609...