13
WATER INLET CONNECTION
409776
Insert the gasket with a filter net into the straight inlet hose attachment nut and screw the
nut onto the water tap (with some models, the gasket with filter net is already fitted and
any additional fitting into the nut on the straight attachment is not required).
A
B
C
A
AQUASTOP
B
TOTAL AQUA-
STOP
C
REGULAR
ATTACHMENT
To ensure correct operation of the appliance, water pressure inlet
must be between 0,05 and 0,8 MPa. Minimum water pressure can
be established by measuring the quantity of poured out water.
3 litres of water must be poured out from completely opened tap
in 15 seconds.
If your model has connections for both hot and cold water, then
connect one hose to the cold water supply (blue wing nut or blue
mark on the hose) and the other one to the hot water supply (red
wing nut or red mark on the hose), as indicated on the back wall
of the appliance (letters C and H) (C - cold; H – hot).
The inlet hose should be tightened manually, firmly enough to
prevent any leaks. After tightening the hose, check for any leaks.
Use of pliers, wrenches, or other similar tools is not allowed when
installing the hose, as these tools can damage the nut thread.