CONTROL SYSTEM FOR DOUGH-RETARDES

 

 

 
 

 

 
 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

REV. 01/04 

READ AND KEEP

 

Use and maintenance manual 

 

ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS 

REV. 01-16  
ENG 

Содержание PLUS 100 PAN

Страница 1: ...PLUS 100 PAN CONTROL SYSTEM FOR DOUGH RETARDES READ AND KEEP Use and maintenance manual ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS REV 01 16 ENG...

Страница 2: ...PLUS 100 PAN...

Страница 3: ...Page 12 5 5 Setting and displaying the set points Page 13 5 6 Level 1 programming Page 14 5 7 List of Level 1 variables Page 15 5 8 Level 2 programming Page 16 5 9 List of Level 2 variables USING THE...

Страница 4: ...100 PAN control panel which features a large LCD display to provide rapidly available complete information on room status The system allows the user to cool heat and ventilate the room switch the roo...

Страница 5: ...ONS IDENTIFICATION DATA The unit described in this manual has on its side an ID plate showing all the relevant identification data Name of Manufacturer Code and model of electrical board Serial number...

Страница 6: ...ducts 4 Minimise the length of connector wires so that wiring does not twist into a spiral shape as this could have negative effects on the electronics 5 Fit a general protection fuse upstream from t...

Страница 7: ...ning signals Adjustment of differential temperature and humidity parameters Adjustment of air changeover control parameters Adjustment of defrosting parameters Adjustment of fan parameters Display of...

Страница 8: ...idity sensor Read resolution 1 C Temperature 1 RH Humidity Sensor read precision 0 5 C see characteristics of humidity sensor Read range 45 45 C 0 99 RH Output characteristics Outputs on relay 1 outpu...

Страница 9: ...Under no circumstances Pego S r l will be responsible for possible loss of data and information costs of substitutive goods or services damages to things people or animals non sale or non gain activi...

Страница 10: ...an automatic cycle Timer press once to show day and time of end of cycle in progress 4 UP Automatic cycle programming 5 Stand by system at standstill does not interrupt cycle in progress 6 SET temper...

Страница 11: ...ion set by final user physically occupies sectors n 11 12 13 14 15 16 4 Progress of PHASE 4 product ready settling max duration 4 hours occupies the last sectors n 17 18 19 20 5 Relative ambient humid...

Страница 12: ...el 2 is for general parameter programming of the various controller work modes It is not possible to access Level 2 programming directly from Level 1 you must exit the programming mode first KEY TO SY...

Страница 13: ...e modified using the or key 4 When the variable has been selected it is possible Display the setting in the respective sector of the display 5 or 17 page 11 To modify the setting by pressing the SET k...

Страница 14: ...st duration time 1 60 min 20 min d6 End of defrosting temperature SET POINT Defrosting is not executed if the temperature read by the defrosting sensor is higher than the end of defrosting setting in...

Страница 15: ...cted it is possible to 2 View the setting in the respective sector of the display 5 or 17 page 11 3 Modify the setting by holding the SET key down and pressing the or key 4 When configuration settings...

Страница 16: ...enable 1 enabled 0 disabled Humidification control only executed during leavening and settling phases 1 CAt Ambient sensor value correction 10 10 C 0 C CAU Humidity sensor value correction 20 20 rH 0...

Страница 17: ...ontrolled 80 rH t5 Fifth leavening step duration hh mm 00 00 2 00 hh mm 00 00 Hr Humidity control Hr 1 humidity control enabled Hr 0 humidity control disabled Humidity sensor can be disconnected witho...

Страница 18: ...d Humidification is activated below the set differential for Humidification parameter d U threshold and stays on until the set point is reached Dehumidification is activated above the set differential...

Страница 19: ...at low speed during the leavening and settling phases Fans are always off during defrosting Variants can be controlled via parameters F5 and F6 AIR CHANGEOVER Air changeover is controlled via paramete...

Страница 20: ...C the controller recognises the manual cold cycle It will consequently run the fans simultaneously with the compressor call and execute the programmed defrosts as per the parameter settings humidity c...

Страница 21: ...04 on the RH display Use keys 4 and 7 to select the recipe to be programmed press key 3 to enter programming mode for the selected recipe The 20 segments at the top of the unit should all be off only...

Страница 22: ...programmable data items for this recipe are therefore AC1 AC2 Co1 Co2 Once programming has been completed you can start a cycle by pressing key 3 for a few seconds The display asks which recipe is to...

Страница 23: ...ew and modify the recipe in use by pressing key 4 for 2 seconds you can vary temperature and humidity but not the duration times of the different stages At the end of the final leavening cycle if sett...

Страница 24: ...leavening duration can never be less than the sum of the 5 parameter programmed steps The settling phase is characterised by Duration in hours 2nd level parameter Temperature set point 2nd level param...

Страница 25: ...ayed at the TeleNET address Ad 1 by setting the module as TWMT temperature acquisition module In this way the TeleNET supervision program can simultaneously display temperature and relative humidity a...

Страница 26: ...e technical assistance service E3 EEPROM ALARM EEPROM memory error detected all outputs deactivated Switch off unit and switch back on If the problem persists change the control board E4 Software comp...

Страница 27: ...anel and Control Board If the problem persists contact the technical assistance service The Control Panel does not respond and the display reads En Incorrect connection between Control Panel and Contr...

Страница 28: ...01 16 The PLUS 100 PAN system does not dialogue with the TeleNET Connection of PLUS 100 PAN system to the TeleNET module network has not been made correctly Check the connection to the TeleNET networ...

Страница 29: ...O A TUTTI GLI EFFETTI DELLE SEGUENTI NORME comprese tutte le modifiche THE CONFORMITY WITH THE REQUIREMENTS OF THIS DIRECTIVE IS TESTIFIED BY COMPLETE ADHERENCE TO THE FOLLOWING STANDARDS including al...

Страница 30: ...d by 31 32 Humidity sensor 4 20 mA 0 100Rh 32 V 31 Y 13 14 Humidification 27 28 Ambient sensor NTC 11 12 Room light 9 10 Evaporator fans low speed Digital inputs section 7 8 Evaporator fans high speed...

Страница 31: ...PLUS 100 PAN Pag 31 USE AND MAINTENANCE MANUAL Rev 01 16 NOTES...