Start-up  Procedure

Peerless 30 CME  Softener

1.      Pipe  ¾” or 1”  inlet and outlet service piping, according to the print, and arrows on bypass.

2.      

Set brine tank in place on a clean, level surface.

  This prevents bottom puncture when weight of water and salt are added.

         Connect brine line (furnished in brine tank) from brine tank to valve.  Line must be air tight.

3.     Connect 5/8” OD poly tubing (not supplied) from valve to suitable drain. 

DO NOT

 use clear collapsible tubing.

4.      With bypass valve in the bypass position, open a cold water tap nearby and let it run a few minutes.  Once free from air, close
         tap.  Partly open bypass to allow water to slowly fill tank.  Once water stops running into tank, rotate bypass valve into the
         full service  position.  Again, open a cold water tap nearby and let the water run until the  water is clear and free of air.

5.     Plug unit into an approved 120V AC outlet.  Press the 

Set Clock

 button once and hour will flash.  Use the up or down

        triangle buttons until the correct hour is displayed.  Press the 

Set Clock

 button again and the minutes will  flash.  Use the up

        or down triangle buttons until the correct minutes are displayed.  Press the 

Set Clock

 button to  finish.

        

NOTE:

  Time of day must be set correctly to either AM or PM.

6.A. Test water, and set computed grains of hardness expressed as gpg (grains per gallon), and iron expressed as ppm (parts per
        million) Do not forget to compensate for iron.  The iron result in ppm should be rounded up to the  nearest whole number.
        Take that number and times it by four (4).  Take that result and add it to the hardness  value.  This is the number you will use
        to set up your control for your specific requirements.
        

NOTE:

  If your iron result is higher than 5 ppm, we recommend an iron filter be installed before the softener.  If an iron

        filter is installed, or you do not have any iron in your water, you do not have to compensate for iron when setting up the
        control for your specific requirements.
   B. To set the total hardness in the unit, press the Next and Up triangle buttons at the 

same time

.

  The display will  show

        

Hardness.

        Press the Up or Down triangle to enter your total hardness result from stop 6.A.
   C. Press the Next button, and the display will show 

Regen Day

.  The factory default is set at 7.  Please do not change this value.

   D. Press the Next button, and the display will show 

Time Regen

.  The factory default is set at 2:00 A.M.  Press the Up or Down

        triangle to change the hour.  Press the Next button and the minutes will flash.  To change press the Up or Down triangle to
        change the minutes.  Press the Next button to finish.

7.     Manually add water to brine tank until water is ½” above the grid.

8.A. Press and hold the Regen button for 5 seconds.  Release when display shows backwash.  Let the water run for 5 minutes.
   B. Press the Regen button and release.  The display will show Brine.  Wait 1 minute.
   C. Press the Regen button and release.  The display will show Backwash.  Wait 1 minute.
   D. Press the Regen button and release.  The display will show Rinse.   Wait one 1 minute.
   E. Press the Regen button and release.   The display will show Fill.  Push down on the float rod to purge air from the brine line.

9.    Fill brine tank with salt.  Peerless recommends Hardi-Cube, Dura-Cube or Mini-Cube or salt substitutes, i.e. Potassium
       Chloride, (trade names) K-Life or Soft Touch.

10.  Open cold water valves in house to relieve air.  Let water run for 3 minutes and test cold water to make sure it is soft.

11.  Hot water from the water heater (unless drained and filled with soft water) will not become soft until the customer has used
       approximately 3 times the holding capacity of the water heater.

12. 

Write the installation date (month/year) on the sticker found inside the front cover.  

     

Rev. 02/2009