background image

IMPORTANT SAFETY INSTRUCTIONS

WARNING: 

When using electric products, basic cautions should always be followed, including the following:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

12.

13.

14.

15.

16.

17.

18.

Read all safety and operating instructions before using this product.

All safety and operating instructions should be retained for future reference.

Obey all cautions in the operating instructions and on the back of the unit.

All operating instructions should be followed.

This product should not be used near water, i.e., a bathtub, sink, swimming pool, wet basement, etc.

This product should be located so that its position does not interfere with its proper ventilation. It should not be placed flat against a
wall or placed in a built-in enclosure that will impede the flow of cooling air.

This product should not be placed near a source of heat such as a stove, radiator, or another heat producing amplifier.

Connect only to a power supply of the type marked on the unit adjacent to the power supply cord.

Never break off the ground pin on the power supply cord. For more information on grounding, write for our free booklet “Shock
Hazard and Grounding.”

Power supply cords should always be handled carefully. Never walk or place equipment on power supply cords. Periodically check
cords for cuts or signs of stress, especially at the plug and the point where the cord exits the unit.

The power supply cord should be unplugged when the unit is to be unused for long periods of time.

If this product is to be mounted in an equipment rack, rear support should be provided.

Metal parts can be cleaned with a damp rag. The vinyl covering used on some units can be cleaned with a damp rag or an 
based household cleaner if necessary. Disconnect unit from power supply before cleaning.

Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other
openings.
This unit should be checked by a qualified service technician if:
a.

The power supply cord or plug has been damaged.

b.

Anything has fallen or been spilled into the unit.
The unit does not operate correctly.

d.

The unit has been dropped or the enclosure damaged.

The user should not attempt to service this equipment. All service work should be done by a qualified service technician.

This product should be used only with a cart or stand that is recommended by Peavey Electronics.

Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in susceptibility to noise
induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time.
The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the following permissible noise level
exposures.

Duration Per Day In Hours

Sound Level 

 Slow Response

8

90

6

92

4

95

3

97

2

100

1

110

 or less

115

According to OSHA, any exposure in excess of the above permissible limits could result in some 

 loss.

Ear plugs or protectors in the ear canals or over the ears must be worn when operating this amplification system in order to prevent a
permanent hearing loss if exposure is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high
sound pressure levels, it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as
this amplification system be protected by hearing protectors while this unit is in operation.

SAVE THESE INSTRUCTIONS!

11

Содержание CS 200X

Страница 1: ......

Страница 2: ...IA Para evitar corrientazos o peligro de incendio no deje expuesto a la lluvia o humedad este aparato Antes de usar este aparato lea mas advertencias en la guia de operation A Ce symbole est utilise pur indiquer a l utilisateur la presence a l interieur de ce produit de tension non isolee dangereuse pouvant tre d intensite suffisante pour constituer un risque de choc Clectrique A Ce symbole est ut...

Страница 3: ...0X contains dual calibrated detented input sensitivity controls a mains power switch an LED power indicator and dual LED DDT activation indicators The rear panel of the CS 200X has dual paralleled l 4 input jacks dual paralleled l 4 output jacks and 5 way binding posts for each channel Additionally the back panel has the stereo bridge select the impedance select and the ground lift switches DDTTM ...

Страница 4: ...nt is just asking for trouble HIGH Z INPUT JACKS 7 Two parallel bridged input jacks are provided for each channel This allows for one to be used as a conven tional input and the other to be used simultaneously as a line out Y cord to connect to another input jack on this amplifier or to other equipment All these l 4 jacks are stereo RING TIP AND SLEEVE and the input circuitry of the CS 200X is ful...

Страница 5: ...conditions can always be considered safe However sustained operation at loads below the impedance selector switch setting per channel and below twice that of the impedance selector switch setting in BRIDGE mode could result in temporary amplifier shut down due to the thermal limits and or the internal fault circuitry A chart listing the allowable loads for the various impedance selector values is ...

Страница 6: ...onic equipment is operated the longer its useful service life STUDIO AND HOME INSTALLATION In most low to medium power applications the CS 200X can be mounted in any configuration It is desirable for if at all possible the unit be located at the top of an equipment stack This will prevent possible overheating of any sensitive equipment by the hot air rising from the power amplifier As a general ru...

Страница 7: ...ntly reduces the potential of loudspeaker degradation and damage The DDT system is an automatic hands off approach to the problem of power amplifier clipping Since the CS 200X power amplifier uses a circuit breaker for over current protection the DDT compression system plays even a more important roll in continuous performance by preventing each channel from clipping and overload Con tinuous opera...

Страница 8: ...MS 4 ohms 16 ohms 20 Hz to 20 kHz 0 07 THD 150 W RMS 8 ohms 32 ohms 20 Hz to 20 kHz 0 05 THD 150 W RMS 16 ohms Distortion Typical Value Stereo mode both channels driven 20 Hz to 20 kHz rated power load Below 0 1 4 ohms 0 07 8 ohms 0 05 16 ohms Input Sensitivity Impedance Input attenuator set FCW rated power load 0 7 V RMS 3 dBV 4 ohms 1 0 V RMS 0 dBV 8 ohms 1 4 V RMS 3 dBV 16 ohms 20 K ohms 28 dB ...

Страница 9: ...t inputs with single feature might conductor shielded eliminate it patch cords Mode Switch I In Stereo Position I Set impedance selector switch to match load impedances t Right output From Mixer t Left output From Mixer TWO CHANNEL MONO MODE If hum is present in system the ground lift feature might eliminate it I Mode Switch In Stereo Position I To Second Set of To First Set 1 Set impedance select...

Страница 10: ... limrted warrantres and the other terms and condrtions expressed herein have been complied with Peavey will provide the necessary warranty service to repair or replace the product and will return It FREIGHT COLLECT to you the purchaser Peavey s liability to the purchaser for damages from any cause whatsoever and regardless of the form of action Including negligence IS limrted to the actual damages...

Страница 11: ...ased household cleaner if necessary Disconnect unit from power supply before cleaning Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other openings This unit should be checked by a qualified service technician if a The power supply cord or plug has been damaged b Anything has fallen or been spilled into the unit c The...

Страница 12: ...Features and specifications subject to change without notice A Peavey Electronics Corporation 711 A Street Meridian MS 39301 U S A 601 483 5365 I Fax 486 1278 01994 80301992 Printed in U S A 4196 ...

Отзывы: