HMI Display Screens
Alarm Description
1.
The alarm description screen lists all the
alarms on the machine.
a.
If there is an alarm present on the
machine, you cannot scroll through
this list; the cause of the active
alarm must be cleared before
continuing.
2.
Use the directional keys to scroll
through the list of alarms.
3.
The display in the top portion of the screen will include relevant
information, including possible causes of, or how to clear an alarm.
4.
See the table below for a list of the alarm descriptions and the respective
information.
Alarm Descriptions
Main Drive Over current
Check for Obstruction in Flights.
Check Flight Drive Mechanical System
Flight Time Exceeded
Check PRS4.
Check Mechanical Drive System of Main Flights
Case Fail to Setup Alarm
Check Transfer of Blank.
Check Pickoff and Set up Vacuum System for Leaks.
Check PE6 and Air Supply.
Motor Protector Tripped
Reset Motor Protector In Electrical Enclosure.
Check Motor of Protector That Was Tripped.
Case at Seal Alarm
Check X-fer of Case to Seal.
Check Flap Plows.
Check Mechanical Setup at Tape Head.
Check PE7
Kickout Clutch Released
Check Prs6.
Check For Obstruction in Flights
Jog Flights to Reset
Tape Failed To Cut
Check Prs5
Check For Proper Tape Installation And Routing
Tape Failed To Apply
Check Prs5
Check For Proper Tape Installation And Routing
5.
Press Main Screen to return to the main screen.