59. Do not press the tool too hard against the workpiece. It is 

not only inefficient but also may cause damages to the 
tool. 

60. Never lay the tool until the accessory has come to a 

complete stop. 

61. Do not abuse the tool. Do not throw, drop or shock the 

tool. 

62. Do not carry the tool by the air hose, and do not pull it to 

disconnect at the same time. 

63. Do not cover or block an exhaust.  Blocked exhaust 

obstructs the tool from working properly. Also, do not 
direct exhaust air towards bystanders and/or animals.  

64. Dress properly. 

65. Do not wear loose fitting clothing or jewelry that could be 

caught in moving parts. 

66. Immediately  stop  operating  the tool  if  you  feel  the 

tool  is  not working correctly. If damaged, have the tool 
serviced.  

67. Stay alert, be careful while operating this tool. Do not use 

tool while tired or under the influence of drugs, alcohol, 
or medications. 

68. Keep children and by standers at a safe distance from 

work area. 

69. Do not use tooling that could be hazaedous if it becomes 

wet. (i.e.grinding stones) 

70. Never place hand or face near a moving accessory. 

71. Use only genuine Pearl replacement parts for repairs. 

72. Always turn it off and disconnect from air compressor 

before installing and removing accessories, before 
adjusting or when making repairs. 

73. Never use damaged accessories. 

74. Wear personal protective equipment such as safety 

glasses that conforms to NSI/ISEA Z87.1, and ear 
protection that conforms to ANSI/ISEA S12.6. 

75. Always securely clamp and support work piece. 

76. Do not use damaged air hose. 

77. Always  wear  proper respiratory protection.  A dust mask  

or  similar dust respirator should be used. 

78. Keep tools clean and lubricated. 

79. Always disconnect tool when not in use, especially when 

changing tools. 

80. Inspect  before using, check alignment  of  moving parts 

and breakage or improper mounting. 

81. Use the Pearl PA6000 for wet grinding only. 

82. Only use a Backing pad rated for 5000 RPM or higher.

      

SPECIFIC WARNINGS FOR PA6000

 

1. Only qualified/trained operators should use this tool. 

2. Use clamps etc. to secure and support the workpiece. 

3. Use accessories made for pneumatic tools. 

4. Hold the tool firmly, especially when starting. 

 

CAUTION

 

1. Do not abuse the tool. Do not throw, drop or shock the 

tool. 

2. Do not carry the tool by the air hose, and at the same 

time, do not pull it to disconnect. 

3. Do not cover or block an exhaust. Blocked exhaust 

prevents the tool from working properly.  Also, never 
direct exhaust air towards bystanders and/or animals. 

4. Dress properly 

5. Do not wear loose fitting clothing or jewelry that could be 

caught in moving parts. 

6. Do not cover or block exhaust. Blocked exhaust prevents 

the tool from working properly. 

7. Immediately stop operating the tool if you feel the tool is 

not working correctly. If damaged have the tool serviced. 

8. Stay alert, be careful while operating this tool. Do not use 

tool while tired or under the influence of drugs, alcohol, 
or medications. 

 

SPECIFIC CAUTION FOR MAINTENANCE

 

1. Immediately stop operating the tool whenever you fell 

that the tool is not working properly. If damaged, have the 
tool serviced. 

2. Use appropriate pressure. Excessively high pressure will 

increase the number of revolutions or strokes causing 
potential failure and accidental injury. 

3. Use only identical replacement parts when servicing. 

4. Do not store unused accessories and tools in an area 

where temperature changes a lot and/or under the direct 
sunlight. Store them in a dry area and out of reach of 
children. 

5. Inspect tool before use; check if parts and accessories are 

free from damage. 

6. Do not use damaged accessory. 

7. Never use solvents or other harsh chemicals to clean the 

non-metallic parts of the tool. 

GENERAL SAFETY RULES AND PRECAUTIONS

Содержание PA6000

Страница 1: ...IC REAR EXHAUST WET GRINDER MODEL PA6000 OWNER S OPERATOR S MANUAL Caution Read Safety and General Instructions carefully before using the tool for the first time serial number You should record the S...

Страница 2: ...FEATURES 7 v SPECIFICATIONS 7 vi UNPACKING ASSEMBLY OPERATION PROCEDURES 8 vii SPECIFIC CAUTION FOR AIR SUPPLY 11 viii ABOUT AIR PRESSURE AND VOLUME 11 ix ABOUT SILENCE 11 x MAINTENANCE TROUBLESHOOTI...

Страница 3: ...12 Always use safety glasses Wear safety glasses must comply with ANSI Z87 1 at all times Everyday eyeglasses only have impact resistant lenses they are not safety glasses Use face or dust mask if cut...

Страница 4: ...rk and have a rest before you get too tired 39 Always check ration direction before use 40 Never place you hand or face near the rotating accessory 42 Do not operate the tool continually at full throt...

Страница 5: ...fore using check alignment of moving parts and breakage or improper mounting 81 Use the Pearl PA6000 for wet grinding only 82 Only use a Backing pad rated for 5000 RPM or higher SPECIFIC WARNINGS FOR...

Страница 6: ...ted Lubricating the tool before and during work is not needed Excessive oil will turn into a tar like substance inside the tool causing the vanes to stick in the rotor and slow the tool down 9 At the...

Страница 7: ...oval number are not recommended because they do little to protect the worker For more information about respirator programs including what respirators have received NIOSH approval as safe and effectiv...

Страница 8: ...required Check the content for the following items before discarding any packaging vi UNPACKING ASSEMBLY OPERATION PROCEDURES PA6000 Air Water Exhaust Hoses Water Hose Joint Hose Nipple Spanner Wrench...

Страница 9: ...se to the grinder air hose fitting 4 Thread the water hose to the water hose fitting 6 Slide the exhaust hose over the water and air hoses 5 Tighten the water hose nut 7 Use the fastener to secure exh...

Страница 10: ...10 OPERATION PROCEDURES 1 Place wrench on bottom of spindle 2 Screw on cup wheel and tighten 3 Turn the water on to desired water volume 4 Use the lever to control air flow Begin grinding...

Страница 11: ...ularly clean the tool s air vents 7 Connect the tool to the air supply as shown below viii ABOUT AIR PRESSURE AND VOLUME 1 The manufacturer specification on the tool is 10 000 RPM at 80 90 PSI Pressur...

Страница 12: ...er attachments be sure to remove the air hose Be sure to use the dry and clean compressed air Don t use the tool in pressure exceeding air pressure 0 63Mpa The air tool is precious machine Don t throw...

Страница 13: ...Check if the air hose is connected in place and air leak found or not 3 Check if the air regulator lever is opened 4 Considering oil level down try idling operation in lubrication WATER WON T COME OU...

Страница 14: ...products 2 Items returned for replacement or refund should be in original cartons and must be accompanied by a packing slip with the following information Returned Goods Authorization RGA number obta...

Страница 15: ...43 Ball Bearing 1 670307 44 Pinion Gear 1 670308 45 Gasket 1 670309 46 Cap Screw 2 670310 47 Pipe Connector 1 670311 48 Inner Pipe 1 670312 49 Angle Head 1 670313 50 Cap Screw 2 670314 51 Screw 1 6703...

Страница 16: ...E OFFICE SO CALIFORNIA USA 4900 ZAMBRANO ST COMMERCE CA 90040 FAX 562 927 5561 562 928 3857 PHONE 800 969 5561 www pearlabrasive com GEORGIA USA 3950 STEVE REYNOLDS BLVD NORCROSS GA 30093 ONTARIO CANA...