Square Wave
Rise or fall time
< 25 ns at full amplitude (50
Ω
) by 100 kHz (typical)
Aberrations
< 10 % of p-p at full amplitude (50
Ω
)
Triangle Linearity error < 1 % up to 100 kHz
Sine Wave Distortion
< 1 % when f < 100kHz; < 30 dB when f > 100 kHz;
< 25 dB when f > 2 MHz
Sync Output
(TTL Pulse)
Source Impedance
50
Ω
± 2 %
Frequency Range
2 Hz to 12 MHz (PeakTech 1006);
2 Hz to 24 MHz (PeakTech 1013)
Symmetry/Duty Cycle 10 % to 90 %; up to 1 MHz
DC Offset
-10 V to +10 V into open circuit; -5 V to + 5 V into 50
Ω
Sweep
Width
Lin or Log up to 100:1
Rate
0.2 H - 100 Hz (5 sec. - 10 msec)
VCO Characteristics
Input impedance
10 k
Ω
± 5 %
Frequendy Range
0 to 10 V input causes 1:100 frequency change
Frequency Counter & TCXO
Range
Frequency: 5 Hz to 100 MHz
Period: 0.2 sec to 10 nsec
Resolution
6 ½ digits
Time base
10 MHz ± 10 ppm (0° C to 50° C)
Attenuation
x 1, x20 nominal
Sensitivity 50
mV
rms
sine wave to 50 MHz; 100 mV
rms
sinewave to 100 MHz
TXCO
Supply voltage: < ± 0.5 ppm for ± 5 % variation; Aging Rate 1 ppm/yr.
Frequency: 10 MHz; Temp.: ± 1 ppm/°C, 0-40° C
General
Weight
3,5
kg
Dimensions
220 mm x 86 mm x 300 mm
Operating Temp.
0° to 40° C
Storage Temp.
-40° to 55° C
Power
115/220 V AC; 50/60 Hz
All rights, also for translation, reprinting and copy of this manual or parts are reserved.
Reproductions of all kinds (photocopy, microfilm or other) only by written permission of the publisher.
This manual is according the latest technical knowing. Technical changings which are in the interest of progress
reserved.
We herewith confirm that the unit is calibrated by the factory according to the specifications as per the technical
specifications.
We recommend to calibrate the unit again, after 1 year.
© PeakTech
®
05/2005